Empire Heating Systems RH-25 Скачать руководство пользователя страница 12

12821-8-0907

Page 12

INDEX

NO.

PART

NUMBER

DESCRIPTION

1

R-6096

Knob & Adaptor Set

11700 

Control Rod Bracket

3

R-2706

ECO Switch

R-8195 

ECO Wire Assembly

5

11699

Control Rod

 6

R-6104

Gas Valve (LPG)

 6

R-6103

Gas Valve (Nat)

 7

11697

Valve Bracket

 8

RH-705

Casing Side

9

RH-708

Air Inlet Baffle

10

P-86-37

Main Burner Orifice, (RH-35-6 Nat)

10

P-86-44 

Main Burner Orifice,
(RH-25-6 Nat)

10

P-86-51

Main Burner Orifice, (RH-35-6 LPG)

10

P-86-54

Main Burner Orifice, (RH-25-6 LPG)

11

P-269

Manifold Assembly

12

RH-818

Diverter Assembly

13

RH-801

Down Draft Shield

14

RH-799

Diverter Plate

15

DV-951

Casing Top

16

11704

Inner Casing Assembly (RH-25-6) (USA)

16

15672

Inner Casing Assembly (RH-25-6) (Canada)

16

11701  

Inner Casing Assembly (RH-35-6) (USA)

16

15673 

Inner Casing Assembly (RH-35-6) (Canada)

17

RH-705

Casing Side

18 

RH-691

Combustion Chamber Assembly (RH-35-6)

18

RH-701

Combustion Chamber Assembly (RH-25-6)

19

M-155 

 Gasket

20

DV-781

Lighting Hole Cover Assembly

21

DV-064

Cover Plate

22

RH-682

Casing Front (USA)

22

15671

Casing Front (Canada)

23

RH-737 

Burner (RH-25-6)

23

RH-738 

Burner (RH-35-6)

24

R-1195 

Thermocouple 36"

25

R-1227 

Pilot Burner with Orifice (Nat)

25

R-1228 

Pilot Burner with Orifice (LPG)

26 

11698

Pilot Tubing

27

R-6120 

Electrode and Wire Assembly

USE ONLY MANUFACTURER’S REPLACEMENT PARTS.   USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Parts can be ordered

 only

 through your 

service person or dealer.

 For best results, the 

service person or dealer

 should order parts through 

the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information.
Furnace Model Number 

    Part Description 

Furnace Serial Number  

  Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc.  

Nine Eighteen Freeburg Ave.   Belleville, IL  62222-0529

INDEX

NO.

PART

NUMBER

DESCRIPTION

PARTS LIST

HOW TO ORDER REPAIR PARTS

Содержание RH-25

Страница 1: ...mma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Страница 2: ...ng 7 Vent Safety Shutoff System 8 Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Mainte...

Страница 3: ...passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the ow of combustion and ventilation air See clearances DO keep the appliance area clear and free...

Страница 4: ...form service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls...

Страница 5: ...r Floor pad is available from Empire Comfort Systems Inc Part Number DVP 1 Quali ed Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair an...

Страница 6: ...pped on the bottom in which condensation and foreign particles may collect Figure 2 Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System 1 To check the inlet pres...

Страница 7: ...n in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brickorstoneconstructionwithouttightstormw...

Страница 8: ...the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switch hole cov...

Страница 9: ...oximately 60 seconds There will be an audible click when the safety magnet in the gas control is de energized Pilot can now be relit Repeat steps 5 through 10 12 Turn gas control knob counterclockwise...

Страница 10: ...will be a short blue inner ame with a larger lighter blue secondary ame The burner ame may have yellow tips when hot Dust in the combustion air will produce an orange or red ame Do not mistake the ora...

Страница 11: ...hen knob is released a Pilot ame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat control a Thermostat needs calibrat...

Страница 12: ...Burner RH 35 6 24 R 1195 Thermocouple 36 25 R 1227 Pilot Burner with Ori ce Nat 25 R 1228 Pilot Burner with Ori ce LPG 26 11698 Pilot Tubing 27 R 6120 Electrode and Wire Assembly USE ONLY MANUFACTURER...

Страница 13: ...12821 8 0907 Page 13 PARTS VIEW...

Страница 14: ...g front Attention Wiring harness on blower is factory assembled and installed If wiring harness becomes disassembled use the follow ing steps to reassemble the wiring harness 1 Attach 1 pinterminalfro...

Страница 15: ...rature dial or thermostat to lowest setting 2 Turn knob on gas control to OFF depressing slightly Do not force Cleaning The blower wheel will collect lint and could require cleaning once a year If the...