Introduction

always consult your local Building Department regarding regulations, 

codes or ordinances which apply to the installation of a direct vent wall 

furnace.

Instructions to Installer

1.  Installer  must  leave  instruction  manual  with  owner  after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with furnace.

3.  Installer should show owner how to start and operate furnace and 

thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This 

is a heating appliance and any panel, door or guard removed for 

servicing an appliance must be replaced prior to operating the 

appliance.

General Information

This furnace is design certified in accordance with American National 

Standard/CSa Standard Z21.86 and CSa 2.32 by the Canadian Standards 

association, as a fan type direct vent wall furnace to be installed according 

to these instructions.

Any alteration of the original design, installed other than as shown in 

these instructions or use with a type of gas not shown on the rating plate 

is the responsibility of the person and company making the change.
Important

all correspondence should refer to complete Model No., Serial No. and 

type of gas.

Notice

: During initial firing of this unit, its paint will bake out and smoke 

will occur. To prevent triggering of smoke alarms, ventilate the room in 

which the unit is installed.

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible 

material other than wood flooring the appliance shall be installed on a metal 

or wood panel extending the full width and depth of the appliance. 

The base referred to above does not mean the fire-proof base as used on 

wood stoves. The protection is for rugs that are extremely thick and light 

colored tile.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so that 

all burners and burner ignition devices are located not less than 18” above 

the floor.

Such equipment shall be located, or protected, so it is not subject to physical 

damage by a moving vehicle. 

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or 

accessories  and  repair  and  servicing  of  equipment  shall  be  performed 

only  by  a  qualified  agency.  The  term  “qualified  agency”  means  any 

individual, firm, corporation or company which either in person or through 

a representative is engaged in and is responsible for (a) the installation 

or replacement of gas piping or (b) the connection, installation, repair or 

servicing of equipment, who is experienced in such work, familiar with 

all precautions required and has complied with all the requirements of the 

authority having jurisdiction.

State of Massachusetts:

 The installation must be made by a licensed 

plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local 

codes, with the 

National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural 

Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 

42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet, input ratings should be reduced 

at the rate of 4 percent for each 1,000 feet above sea level. For Canadian 

high  altitude  applications,  this  appliance  is  suitable  for  installation  at 

elevations between 0 feet and 4,500 feet  without change

.

Piezo Pilot Ignitor Instructions

Depressing the red button completely causes a spark to occur at the pilot. This 

is a substitute for a match which requires opening the pilot hole cover.
To  light  the  pilot,  it  is  important  that  the  electrode  be  1/8”    from  the 

thermocouple. The spark must occur at the point the burner flame hits the 

thermocouple. The end of the electrode will be red hot with the pilot on.
On a new installation with air in the gas line, it is suggested that a match 

be used. The match will light the pilot faster than the piezo under this 

condition. 

Model

DVC-35T

DVC-35IPT

Input BTU/HR

35,000

35,000

Height

72 1/2”

72 1/2”

Width

14 1/8”

14 1/8”

Depth

10 3/8”

10 3/8”

Gas Inlet

1/2” Pipe

1/2” Pipe

CFM

275

275

Accessories

SOR-1

Register, Side Outlet

SOK-1

Side Outlet Kit, 10” (25.4cm) Boot Assembly with Register

*DV-822

Vinyl Siding Vent Kit

*  DV-822, Vinyl siding vent kit, adds 3” to wall depth. You must include the three (3) additional inches for 

TOTAL

 wall depth when ordering a 

vent kit.

INTRODUCTION

SPECIFICATIONS

Содержание DVC-35IPT-1

Страница 1: ...ss a certified kit is used Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the...

Страница 2: ...C 35T Standing Pilot Lighting Instructions 12 DVC 35IPT Intermittent Pilot Lighting Instructions 13 Pilot Flame Characteristics 14 Main Burner Flame Characteristics 15 Wiring 15 16 Service and Mainten...

Страница 3: ...g system periodically and replace damaged parts Do make a periodic visual check of pilot and burners Clean and replace damaged parts CAUTION Pilot hole cover must be kept tightly closed during operati...

Страница 4: ...t lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorpti...

Страница 5: ...requiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the ex...

Страница 6: ...tallation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any...

Страница 7: ...iance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve...

Страница 8: ...l depths of 8 to 12 or 12 to 19 The use of tubes not supplied by the manufacturer results in unsatisfactory performance 3 The DVC 35T and DVC 35IPT can be attached to the wall or recessed into the wal...

Страница 9: ...h two 2 10 x 1 provided screws 9 Installation of SOR 1 is completed Side outlet kit SOK 1 10 boot assembly with register for warm air discharge into an adjoining room may be installed on either side o...

Страница 10: ...tlet box with four 4 10 x 1 2 screws Attention Do not overtighten screws because outlet box must be able to move as flue tube expands and contracts Place collar on six inch air tube against air drop A...

Страница 11: ...ist page 16 to order tubes Figure 10 Figure 11 appropriate vent kit for measured wall depth the vent tubes will fit together 1 Place caulking not provided beneath the collar of the outside mounting pl...

Страница 12: ...l knob slightly and turn clockwise to OFF Do not force 5 Replace control access panel lower front panel Lighting Instructions 1 Stop Read the safety information above 2 Set the thermostat to lowest se...

Страница 13: ...artofthecontrolsystem and any gas control which has been under water 1 Stop Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 Th...

Страница 14: ...in turn lights the main burner The gas valve used in this system is a step opening which opens at a lower pressure for ignition and then steps to a full inlet pressure of 4 pressure on Natural gas and...

Страница 15: ...er heater etc including walls and doorways with a heat source in an adjoining room Do Not Install Thermostat on Outside Wall CAUTION Label all wires prior to disconnection when servicing controls Wiri...

Страница 16: ...ASSY PILOT OUTLET PILOT ADJUSTMENT UNDER CAP SCREW OUTLET PRESSURE TAP TO 24V HOT ON TRANSFORMER CONTROL IGNITOR CONTROL IGNITOR WIRING 40 VA TRANSFORMER 120 VAC 24 VAC FAN SWITCH MOTOR 120 VAC VALVE...

Страница 17: ...for being in the Pilot position 2 Checkpilotadjustmentforbeingfullopen counterclockwise to open 3 Ifgasisavailableinthesupplytubing thepilotorificeand or pilot burner is probably restricted by a spide...

Страница 18: ...all for Heat Ends Flame Signal Lost Pilot Valve Ignition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for Hea...

Страница 19: ...Burner Cable Check that Pilot Gas is Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Ig...

Страница 20: ...3163 FILTER RETAINER 26 R 3232 PILOT NAT IP ONLY 26 R 3233 PILOT LPG IP ONLY 27 P 88 52 ORIFICE NAT 3 REQUIRED 27 P 88 60 ORIFICE LPG 3 REQUIRED 28 DV 1236 MANIFOLD 29 DV 1259 FRONT PANEL 30 P 112 MA...

Страница 21: ...13119 10 0709 Page 21 PARTS VIEW...

Страница 22: ...13119 10 0709 Page 22 SERVICE NOTES...

Страница 23: ...13119 10 0709 Page 23 SERVICE NOTES...

Страница 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...