background image

13119-10-0709

Page 20

Parts can be ordered

 only

 through your 

service person or dealer.

 For best results, the 

service person or dealer

 should order parts through 

the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information.
Furnace Model Number

    Part Description 

Furnace Serial Number 

 

Part Number 

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 

Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc. 

Nine eighteen Freeburg ave.  Belleville, IL 62222-0529

PLEASE NOTE: 

When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

Index 

Part

 No. 

Number 

Description

 USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INjURY OR DEATH.

  1 

DV-1213 

TOP PLaTe

  2 

R-3165 

DOOR CLIP (2 REQUIRED)

  3 

DV-1204 

CaSING SIDe - RIGHT

  4 

DV-1202 

CaSING BaCK

  5 

DV-1205 

CaSING SIDe - LeFT

  6 

DV-1249 

aIR DROP

  7 

DV-1230 

TURBULATOR (3 REQUIRED)

  8 

13213 

OUTLeT BOX ReaR

  9 

13217 

OUTLeT BOX COVeR 

  10 

R-3161 

FaN BLaDe

  11 

R-3166 

FaN MOTOR

  12 

DV-1246 

MOTOR MOUNTING BRaCKeT

  13 

R-1536 

BUSHING (4 REQUIRED)

  14 

R-1499 

RUBBER GROMMET (4 REQUIRED)

  15 

R-1454 

BRASS BUSHING  (4 REQUIRED)

  16 

R-3164 

DOOR CLIP (2 REQUIRED)

  17 

DV-1251 

INNER SHIELD - RIGHT (INCLUDES 

NO. 22)

  18 

R-6176 

FaN CONTROL SWITCH

  19 

R-3175 

LIMIT SWITCH

  20 

DV-1255 

INNeR SHIeLD FRONT

  21 

DV-1253 

INNER SHIELD COVER PLATE (2 

REQUIRED)

  22 

DV-1252 

INNER SHIELD -LEFT (INCLUDES 

NO. 22)

  23 

13211 

eXCHaNGeR aSSeMBLY

  24 

R-3162 

FILTeR

  25 

R-3163 

FILTeR ReTaINeR

  26 

R-3232 

PILOT - NAT (IP ONLY)

  26 

R-3233 

PILOT - LPG (IP ONLY)

  27 

P-88-52 

ORIFICE - NAT (3 REQUIRED)

  27 

P-88-60 

ORIFICE - LPG (3 REQUIRED)

  28 

DV-1236 

MaNIFOLD

  29 

DV-1259 

FRONT PaNeL

  30 

P-112 

MaNIFOLD UNION

  31 

R-1109 

BUSHING (3/8 X 1/2)

  31 

R-9505 

BUSHING (1/2 X 3/4) - NAT (IP ONLY)

  32 

R-3170 

GAS VALVE - NAT (IP ONLY)

  32 

R-3171 

GAS VALVE - LPG (IP ONLY)

  32 

R-2148 

GAS VALVE - NAT (SPP ONLY)

  32 

R-5655 

GAS VALVE - LPG (SPP ONLY)

  33 

R-2708 

PIEZO IGNITOR (SPP ONLY)

  34 

DV-781 

OBSeRVaTION HOLe COVeR aS-

SeMBLY

  35 

M-155 

GaSKeT

  36 

FF-160 

PIEZO BRACKET (SPP ONLY)

  37 

DV-1240 

BURNeR COMPaRTMeNT FRONT

  38 

DV-1265 

BURNeR COMPaRTMeNT BODY

Index 

Part

 No. 

Number 

Description

  39 

M-156 

GaSKeT

  40 

DV-775 

SEAL BRACKET (SPP ONLY)

  40 

DV-691 

SEAL BRACKET (IP ONLY)

  41 

M-148 

MaNIFOLD GaSKeT

  42 

DV-1235 

PILOT BRACKET (IP ONLY)

  43 

R-3031 

BURNER (3 REQUIRED)

  44 

DV-1239 

BURNeR BRaCKeT

  45 

UH-810 

TRaNSFORMeR MOUNTING BRaCKeT 

(SPP ONLY)

  45 

UH-452 

TRANSFORMER MOUNTING BRACKET (IP 

ONLY)

  46 

R-1995 

TRANSFORMER (SPP ONLY)

  46 

R-998 

TRANSFORMER (IP ONLY)

  47 

UH-451 

JUNCTION BOX COVeR

  48 

DV-572 

JUNCTION BOX

  49 

R-1410 

BUSHING

  50 

R-690 

CORD SeT

  51 

R-1515 

BUSHING

  52 

DV-1215 

BOTTOM PLaTe

  53 

R-3034 

PILOT - NAT (SPP ONLY)

  53 

R-3035 

PILOT - LPG (SPP ONLY)

  54 

GWT-021 

PILOT BRACKET (SPP ONLY)

  55 

R-3180 

ELECTRODE AND WIRE ASSEMBLY (SPP 

ONLY)

  56 

R-2256 

THERMOCOUPLE -18” (SPP ONLY)

  57 

R-6389 

WaLL THeRMOSTaT - 24 VOLT

  58 

13057 

OUTLET TUBE - INNER ASSEMBLY (IN

-

CLUDeS 59 & 60)

  59 

M-177 

GaSKeT - OUTeR COLLaR

  60 

13104 

OUTLeT TUBe - INNeR WeLDeD aSSeM-

BLY

  61 

13062 

INLET TUBE - INNER ASSEMBLY (IN

-

CLUDeS 62 & 63)

  62 

M-178 

GaSKeT - INLeT COLLaR

  63 

13106 

INLeT TUBe - INNeR WeLDeD aSSeMBLY

  64 

13064 

INLeT TUBe - OUTeR aSSeMBLY

  65 

13059 

OUTLeT TUBe - OUTeR aSSeMBLY

  66 

13053 

VeNT CaP WeLDeD aSSeMBLY 

NOT SHOWN  DV-1261 

PILOT TUBING 

NOT SHOWN  R-1081 

PILOT ORIFICE - NAT (SPP ONLY)

NOT SHOWN  R-1089 

PILOT ORIFICE - LPG (SPP ONLY)

NOT SHOWN  R-1233 

PILOT ORIFICE - NAT (IP ONLY)

NOT SHOWN  R-3265 

PILOT ORIFICE - LPG (IP ONLY)

NOT SHOWN  R-3172 

WIRE HARNESS (SPP ONLY)

NOT SHOWN  R-3173 

WIRE HARNESS (IP ONLY)

NOT SHOWN  R-3236 

WIRE (IP ONLY)

NOT SHOWN  DV-1264 

HaRDWaRe PaCKaGe

HOW TO ORDER REPAIR PARTS

PARTS LIST

Содержание DVC-35IPT-1

Страница 1: ...ss a certified kit is used Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the...

Страница 2: ...C 35T Standing Pilot Lighting Instructions 12 DVC 35IPT Intermittent Pilot Lighting Instructions 13 Pilot Flame Characteristics 14 Main Burner Flame Characteristics 15 Wiring 15 16 Service and Mainten...

Страница 3: ...g system periodically and replace damaged parts Do make a periodic visual check of pilot and burners Clean and replace damaged parts CAUTION Pilot hole cover must be kept tightly closed during operati...

Страница 4: ...t lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorpti...

Страница 5: ...requiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the ex...

Страница 6: ...tallation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any...

Страница 7: ...iance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve...

Страница 8: ...l depths of 8 to 12 or 12 to 19 The use of tubes not supplied by the manufacturer results in unsatisfactory performance 3 The DVC 35T and DVC 35IPT can be attached to the wall or recessed into the wal...

Страница 9: ...h two 2 10 x 1 provided screws 9 Installation of SOR 1 is completed Side outlet kit SOK 1 10 boot assembly with register for warm air discharge into an adjoining room may be installed on either side o...

Страница 10: ...tlet box with four 4 10 x 1 2 screws Attention Do not overtighten screws because outlet box must be able to move as flue tube expands and contracts Place collar on six inch air tube against air drop A...

Страница 11: ...ist page 16 to order tubes Figure 10 Figure 11 appropriate vent kit for measured wall depth the vent tubes will fit together 1 Place caulking not provided beneath the collar of the outside mounting pl...

Страница 12: ...l knob slightly and turn clockwise to OFF Do not force 5 Replace control access panel lower front panel Lighting Instructions 1 Stop Read the safety information above 2 Set the thermostat to lowest se...

Страница 13: ...artofthecontrolsystem and any gas control which has been under water 1 Stop Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 Th...

Страница 14: ...in turn lights the main burner The gas valve used in this system is a step opening which opens at a lower pressure for ignition and then steps to a full inlet pressure of 4 pressure on Natural gas and...

Страница 15: ...er heater etc including walls and doorways with a heat source in an adjoining room Do Not Install Thermostat on Outside Wall CAUTION Label all wires prior to disconnection when servicing controls Wiri...

Страница 16: ...ASSY PILOT OUTLET PILOT ADJUSTMENT UNDER CAP SCREW OUTLET PRESSURE TAP TO 24V HOT ON TRANSFORMER CONTROL IGNITOR CONTROL IGNITOR WIRING 40 VA TRANSFORMER 120 VAC 24 VAC FAN SWITCH MOTOR 120 VAC VALVE...

Страница 17: ...for being in the Pilot position 2 Checkpilotadjustmentforbeingfullopen counterclockwise to open 3 Ifgasisavailableinthesupplytubing thepilotorificeand or pilot burner is probably restricted by a spide...

Страница 18: ...all for Heat Ends Flame Signal Lost Pilot Valve Ignition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for Hea...

Страница 19: ...Burner Cable Check that Pilot Gas is Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Ig...

Страница 20: ...3163 FILTER RETAINER 26 R 3232 PILOT NAT IP ONLY 26 R 3233 PILOT LPG IP ONLY 27 P 88 52 ORIFICE NAT 3 REQUIRED 27 P 88 60 ORIFICE LPG 3 REQUIRED 28 DV 1236 MANIFOLD 29 DV 1259 FRONT PANEL 30 P 112 MA...

Страница 21: ...13119 10 0709 Page 21 PARTS VIEW...

Страница 22: ...13119 10 0709 Page 22 SERVICE NOTES...

Страница 23: ...13119 10 0709 Page 23 SERVICE NOTES...

Страница 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: