INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING
Brief Description of the Components
The gas valve is equipped with a manual HI/LO knob to allow for
manual modulation of the gas outlet pressure. The manual HI/LO
knob can be replaced by an Empire Comfort Systems Variable
Remote Kit.
WARNING
This appliance is equipped for Natural or Propane Gas.
Field conversion is not permitted.
The Digital Fireplace Control (DFC) is an automatic gas ignition
system based on a single microcontroller core. This control man-
ages all functions related to ignition, flame sensing and supervi-
sion for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition
control sequences and flame monitoring with safety shutdown in
case of failure.
The DFC is set up as a stand alone (AC powered system with
battery back up. See Lighting Instructions on page 26 and Wiring
Diagram on page 28.
Troubleshooting
Before proceeding with the procedures in the following trouble-
shooting table, verify that the power supply (AC/DC adapter) is
present and that the batteries inside the receiver and/or optional
battery pack are fresh and installed with correct polarity.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s rec-
ommended inlet pressure. If necessary adjust the line pressure
regulator.
If the recommended actions for the following troubleshooting chart
do not help to address the problem consider replacing wiring har-
nesses.
WARNING
Any actions performed on the gas valve must be performed
in accordance with this instruction manual. Likewise, any
actions performed on the DFC or other system components
must be done in accordance with the individual component
instructions.
Replacement of components must be performed in accor
-
dance with this instructions manual.
Содержание White Mountain Hearth VFP24FP20LN-1
Страница 15: ...30411 17 0120 Page 15 1 Place Log A between rear log support and burner pan See image below LOG PLACEMENT ...
Страница 16: ...30411 17 0120 Page 16 2 Place Log B onto the two left front pins on the burner pan LOG PLACEMENT ...
Страница 17: ...30411 17 0120 Page 17 3 Place Log C onto the two right front pins on burner pan See image below LOG PLACEMENT ...
Страница 18: ...30411 17 0120 Page 18 4 Log set assembly is complete LOG PLACEMENT ...