background image

30411-17-0120

Page 10

GAS SUPPLY

Check all local codes for requirements, especially for the size and 

type of gas supply line required.

RECOMMENDED GAS PIPE DIAMETER

Pipe 

Length

Schedule 40 Pipe

Inside Diameter

Tubing, Type L 

Outside Diameter

Natural

Propane

Natural

Propane

0-10 feet

0-3 meters

1/2”

12.7mm

3/8”

9.5mm

1/2”

12.7mm

3/8”

9.5mm

10-40 feet

4-12 meters

1/2”

12.7mm

1/2”

12.7mm

5/8”

15.9mm

1/2”

12.7mm

40-100 feet

13-30 meters

1/2”

12.7mm

1/2”

12.7mm

3/4”

19mm

1/2”

12.7mm

100-150 feet

31-46 meters

3/4”

19mm

1/2”

12.7mm

7/8”

22.2mm

3/4”

19mm

NOTICE

Never use plastic pipe. Check to confirm whether your 

local codes allow copper tubing or galvanized.

NOTICE

:

 Since some municipalities have additional local codes, it 

is always best to consult your local authority and installation code.

Installing a New Main Shut-Off Valve 

Each appliance should have its own manual shut-off valve.

A manual main gas shut-off should be located in the vicinity of the 

unit. Where none exists, or where its size or location is not adequate, 

contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant 

to the action of liquefied petroleum gases. The gas lines must be 

checked for leaks by the installer. This should be done with a soap 

solution watching for bubbles on all exposed connections, and if 

unexposed, a pressure test should be made. 

Never use an exposed flame to check for leaks. Appliance must 

be disconnected from piping at inlet of control valve and pipe 

capped or plugged for pressure test. Never pressure test with 

appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas 

line upstream of the gas control to aid in servicing. It is required by 

the National Fuel Gas Code that a drip line be installed near the gas 

inlet. This should consist of a vertical length of pipe tee connected 

into the gas line that is capped on the bottom in which condensation 

and foreign particles may collect.

The use of the following gas connectors is recommended:

—  ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing 

and Fittings

—  ANS Z21.45 Assembled Flexible Appliance Connectors of Other 

Than All-Metal Construction

The above connectors may be used if acceptable by the authority 

having jurisdiction. The Commonwealth of Massachusetts requires 

that a flexible appliance connector cannot exceed three feet in length.

GAS SUPPLY PLUMBING

MANUAL

SHUT-OFF VALVE

GAS SUPPLY

INLET

DRIP LEG

3” MINIMUM

TO CONTROL

VALVE

Figure 14

Pressure Testing of the Gas Supply System

1.   To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. 

plugged tapping, accessible for test gauge connection, must 

be placed immediately upstream of the gas supply connection 

to the appliance.

2.  The appliance and its individual shut-off valve must be 

disconnected from the gas supply piping system during any 

pressure testing of that system at test pressures in excess of 

1/2 psig (3.5 kPa).

3.   The appliance must be isolated from the gas supply piping 

system by closing its individual manual shut-off valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than 1/2 psig (3.5 kPa).

Figure 3

Attention!

 If one of the above procedures results in pressures in 

excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, 

it will result in a hazardous condition.

Checking Manifold Pressure

Millivolt and Intermittent Models 

Natural Gas will have a manifold 

pressure of approximately 3.5" w.c. (.871kPa) for maximum input or 

1.7" w.c. (.423kPa) for minimum input at the pressure regulator outlet 

with the inlet pressure to the pressure regulator from a minimum 

of 5.0" w.c. (1.120kPa) for the purpose of input adjustment to a 

maximum of 10.5" w.c. (2.614kPa). 

Hydraulic Thermostat Models

 Natural Gas will have a manifold 

pressure  of  approximately  6.0"  w.c.  (1.49kPa)  at  the  pressure 

regulator outlet with the inlet pressure to the pressure regulator 

from  a  minimum  of  7.0"  w.c.  (1.74kPa)  for  the  purpose  of  input 

adjustment to a maximum of 10.5" w.c. (2.615kPa). 

Millivolt and Intermittent Models

 Propane Gas will have a manifold 

pressure approximately 10.0"w.c. (2.49kPa) for maximum input or 

6.3"w.c. (1.568kPa) for minimum input at the pressure regulator outlet 

with the inlet pressure to the pressure regulator from a minimum 

of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a 

maximum of 13.0"w.c. (3.237kPa). 

Hydraulic Thermostat Models

 Propane Gas will have a manifold 

pressure approximately 10.0"w.c. (2.49kPa) at the pressure regulator 

outlet with the inlet pressure to the pressure regulator from a minimum 

of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a 

maximum of 13.0"w.c. (3.237kPa). 

Содержание White Mountain Hearth VFP24FP20LN-1

Страница 1: ... gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If not installed operated and maintained in accordance with the manufacturer s instructions this prod...

Страница 2: ...E APPEARANCE 19 PILOT FLAME CHARACTERISTICS 20 HYDRAULIC THERMOSTAT MODELS LIGHTING INSTRUCTIONS 21 10 000 BTU MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS 22 MILLIVOLT CONTROL LIGHTING INSTRUCTIONS 23 MILLIVOLT WIRING 24 MILLIVOLT TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES AND CORRECTIONS 25 INTERMITTENT PILOT LIGHTING INSTRUCTIONS 26 INTERMITTENT CONTROL SYSTEM OPERATING INSTRUCTIONS 27 INTERMITT...

Страница 3: ...r 8 Do not place rock wool embers over the large ports of the burner 9 Checklevelofceramicmediainburner iftheburnerhasceramic media Burner should be full up to the level of the openings in the burner top 10 Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and or sooting 11 Install logs according to the installation instructions Do ...

Страница 4: ...1 0 MODEL GAS VALVE TYPE ORIFICE BTUH MAX RATE BTUH MIN RATE VFP24FP2 0 1 2 3 LN N Hydraulic 49 20 000 10 000 VFP24FP2 0 1 2 3 LP P Hydraulic 55 20 000 10 000 VFP24FP3 0 1 2 3 LN N Millivolt 43 20 000 14 000 VFP24FP3 0 1 2 3 LP P Millivolt 55 20 000 14 000 VFP24FP3 0 1 2 3 L10N N Millivolt 53 10 000 10 000 VFP24FP3 0 1 2 3 L10P P Millivolt 64 10 000 10 000 VFP24FP7 0 1 2 3 LN N IP 43 20 000 14 000...

Страница 5: ... firebox 11 D The height of the firebox opening 17 1 2 E The width of the firebox opening 19 1 2 F The interior depth of the firebox not shown 9 3 8 G The rear exterior width of the firebox not shown 17 1 4 K Height from the bottom of the box to the gas line opening 2 5 8 L Depth from the front of the box to gas line opening 4 13 16 M Depth from rear of box to gas line opening 6 1 8 Q Distance fro...

Страница 6: ...can be installed with zero clearance to combustible material When facing the front of the appliance the minimum clearances to combustible construction material are the following 1 Clearancesfromtherightsideorleftsideofthefireplaceopening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 34 ...

Страница 7: ...omatic Blower VPP1A 22 Aged Brick Liner VFF24HP 1 Hammered Pewter Trim Kit Accessories for Millivolt and Intermittent Models Only FRBC Battery Operated Remote Control FRBTC Battery Operated Remote Control w Thermostat FREC Electric Remote Control FWS Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat c Caulking or sealants are applied to areas such as joints ...

Страница 8: ... You will need no additional fresh air ventilation WARNING You must provide additional ventilation air in a confined space Ventilation Air Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoiningunconfinedspace When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting...

Страница 9: ...ndards Association as an Unvented Room Heater and should be installed according to these instructions Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change Important All correspondence should refer to complete Model Number Serial Number and t...

Страница 10: ...The above connectors may be used if acceptable by the authority having jurisdiction The Commonwealth of Massachusetts requires thataflexibleapplianceconnectorcannotexceedthreefeetinlength GAS SUPPLY PLUMBING MANUAL SHUT OFF VALVE GAS SUPPLY INLET DRIP LEG 3 MINIMUM TO CONTROL VALVE Figure 14 Pressure Testing of the Gas Supply System 1 To check the inlet pressure to the gas valve a 1 8 3mm N P T pl...

Страница 11: ...ing flange will secure the fireplace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four pre drilled screw holes on back of breastboard to secure breastboard to mantel sides with four Phillips wood screws 8 Place mantel top onto mantel 9 Installation of fireplace into mantel is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from firepla...

Страница 12: ...his time When facing the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert fireplace into enclosure 4 Attach nailing flanges to framing with a screw or nail 5 Finishedwallsurfacewillbeflushtotheleadingedgeoffireplace top and sides 6 Installation of built in fireplace is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from fireplace 3 Remove ...

Страница 13: ...30411 17 0120 Page 13 VFP24 LOG IDENTIFICATION Log Description Part Number Front View Top View Log A R7506 Log B R7504 Log C R7505 ...

Страница 14: ... is very important that part num ber and description of part coincide Use Only Manufacturer s Replacement Parts Use of Any Other Parts Could Cause Injury Or Death LOG PLACEMENT Glowing Ember Placement WARNING All previously applied Glowing Embers must be removed prior to reapplication Applying Glowing Embers as shown in the image below NotICE Application of excess Glowing Embers may adversely affe...

Страница 15: ...30411 17 0120 Page 15 1 Place Log A between rear log support and burner pan See image below LOG PLACEMENT ...

Страница 16: ...30411 17 0120 Page 16 2 Place Log B onto the two left front pins on the burner pan LOG PLACEMENT ...

Страница 17: ...30411 17 0120 Page 17 3 Place Log C onto the two right front pins on burner pan See image below LOG PLACEMENT ...

Страница 18: ...30411 17 0120 Page 18 4 Log set assembly is complete LOG PLACEMENT ...

Страница 19: ...checked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTICE all flames will be random by design flame height will go up and down Glowing embers rock wool can cover the pan burner in between the front and middle logs but very little is necessary to cover this area Excess ember material causes the yellow flam...

Страница 20: ...Pilot Flame Pattern THERMOCOUPLE LPG THERMOCOUPLE NATURAL THERMOPILE PILOT Millivolt Pilot Figure 13 PILOT THERMOCOUPLE NATURAL THERMOCOUPLE LPG Hydraulic Thermostat Pilot Figure 14 PILOT SENSOR IGNITOR Intermittent Pilot Figure 15 Incorrect Pilot Flame Pattern THERMOCOUPLE LPG THERMOCOUPLE NATURAL THERMOPILE PILOT Millivolt Pilot Figure 16 PILOT THERMOCOUPLE LPG THERMOCOUPLE NATURAL Hydraulic The...

Страница 21: ...TOP Follow B in the safety information on other side If you do not smell gas Go to the Next step 6 Find pilot the pilot is located in front of rear log 7 Turn manual gas control knob counterclockwise to PILOT 8 Push in manual gas control knob all the way and hold in Re peatedly push the piezo ignitor button until pilot is lit or use a match to light Continue to hold the control knob in for about o...

Страница 22: ...OTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety infor mation above If you do not smell gas go to the next step 7 Find pilot Follow metal tube from gas control The pilot is...

Страница 23: ...mbly 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF un less knob is pushed in slightly Do not force 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information abov...

Страница 24: ...C CETTE UNITE DOIT ETRE REMPLACE VOUS DEVEZ LE REMPLACER AVEC UN FIL ELECTRIQUE DE NUMERO 18 150 C DU L EQUIVALENT THERMOPILE GAS VALVE THERMOCOUPLE NATURAL OFF ON REMOTE OPTIONAL REMOTE CONTROL RECEIVER FACULTATIVE CONTROLE E DISTANCE DU RECEPTEUR OPTIONAL WALL SWITCH INTERRUPTEUR MURAL FACULTATIVE OPTIONAL THERMOSTAT FACULATIVE THERMOSTAT WIRING DIAGRAM GAS VALVE VALVE DE GAZ REMOTE OFF ON SWITC...

Страница 25: ...s not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loose at control valve Hand ti...

Страница 26: ...STRUCTIONS 1 STOP Read the safety information above 2 Turn OFF electric power to the appliance 3 Remove front surround panel assembly or bottom louver if included 4 Turn gas shut off counterclockwise to On position 5 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this page If you do not smell gas g...

Страница 27: ...During the operating season or in power outage periods it is recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as shown in Figure 23 Refer to page 8 for gas pressure requirements Note The gas control has a manual HI LO flame adjustment knob regula...

Страница 28: ...manently located manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases CAUTION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alteration service or maintenance can cause property damage pe...

Страница 29: ...ighting Instructions on page 26 and Wiring Diagram on page 28 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections between the wire harnesses and system comp...

Страница 30: ...lean flame sensor and pilot igniter See maintenance page 39 Pilot not grounded well Check ground connections Sensor Wire loose Check sensor wire terminals Gas pressure incorrect Adjust gas pressure Pilot Gas Line bent or kinked Replace pilot tube Faulty pilot Sensor bent Replace Pilot Faulty valve Replace Valve Burner takes too long to fully light Low gas pressure Check gas supply pressure Clogged...

Страница 31: ...ce Check orifice opening Clogged or dirty burner ports Clean burner ports Faulty valve Replace valve High altitude Adjust orifice size for altitude Backfire of burner Blocked orifice Check orifice opening Clogged or dirty burner ports Clean burner ports Low gas pressure Check gas supply pressure Fireplace produces unwanted odors Vapors from paint hairspray glue etc Ventilate room until odor stops ...

Страница 32: ...24 PILOT ASSEMBLY NATURAL 20 P 214 ORIFICE NATURAL 10 000 BTU 20 P 181 ORIFICE NATURAL 20 000 BTU 20 P 193 ORIFICE PROPANE 10 000 BTU 20 P 182 ORIFICE PROPANE 20 000 BTU 23 R3626 VALVE NATURAL 20 000 BTU 23 R3625 VALVE PROPANE 20 000 BTU 23 R9368 VALVE NATURAL 10 000 BTU 23 R9369 VALVE PROPANE 10 000 BTU 24 R2423 MALE ADAPTOR 25 25787 TUBING VALVE TO BURNER 26 25805 TUBING VALVE TO PILOT PROPANE 2...

Страница 33: ...AL ONLY 28 31363 TUBING ASSEMBLY REGULATOR TO PILOT NATURAL 34 R2522 SWITCH ON OFF 35 29699 BRACKET ON OFF SWITCH 36 R11127 CONTROL BOARD N A R11128 POWER ADAPTOR INDEX NUMBER PART NUMBER DESCRIPTION VFP24FP70L10 18 R11328 2019 PILOT ASSEMBLY NATURAL 18 R11327 2019 PILOT ASSEMBLY Propane 19 R5676 AIR SHUTTER NATURAL 19 R5675 AIR SHUTTER PROPANE 20 P214 ORIFICE 53 VFP24FP70L10N 20 P193 ORIFICE 64 V...

Страница 34: ...TS VIEW 1 3 2 4 4 5 6 7 8 9 9 10 11 14 15 18 16 17 21 20 19 22 5 12 13 12 23 26 25 31 30 29 33 32 23 24 25 29 32 34 33 26 27 28 21 20 19 18 17 16 22 36 26 27 25 24 23 35 34 28 26 VFP24FP2 Series VFP24FP3 Series VFP24FP7 Series ...

Страница 35: ...nsor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by loosening nut B from the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air pressure through the holes indicated by the arrows This will blow out foreign materials such as dust lint and spider webs Tighten nut B also by grasping nut A...

Страница 36: ... are necessary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on surfaces outside the fireplace See instructions for proper installation WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns WARNING Donotuseablowerinsert heatexchangerinsert or other accessory not approved for us...

Страница 37: ...s can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any od...

Страница 38: ...ase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be ...

Страница 39: ...ective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to t...

Страница 40: ...ire Comfort Systems Inc Belleville Illinois If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: