background image

EMPIRE

EMPIRE

Comfort Systems

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

CAST IRON 

UNVENTED ROOM HEATER

MODELS

VFP30CA30(B,F,M,S,W)N-1

VFP30CA30(B,F,M,S,W)P-1

WATER  VAPOR:  A  BY-PRODUCT  OF 

UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An 

unvented room heater produces approximately one 

(1) ounce (30 ml) of water for every 1,000 BTU's 

(.3KW's) of gas input per hour. Refer to page 6.

WARNING: If not installed, operated and main-

tained  in  accordance  with  the  manufacturer's 

instructions,  this  product  could  expose  you  to 

substances in fuel or from fuel combustion which 

can cause death or serious illness.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation 

air must be provided. Refer to page 7 .

This appliance may be installed in an aftermarket, 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes. 
This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases.

The Heritage Cast Iron Stoves

GAS-FIRED

—  Do not store or use gasoline or other flamma-

ble vapors and liquids in the vicinity of this or 

any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately call your gas supplier from a 

neighbor’s  phone.  Follow  the  gas  suppli-

er’s instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

—  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING: If the information in these instruc-

tions are not followed exactly, a fire or explosion 

may result causing property damage, personal 

injury or loss of life.

Installer:  Leave  this  manual  with  the  appli-

ance.

Consumer: Retain  this  manual  for  future  

reference.

Page 1

Содержание VFP30CA30BN-1

Страница 1: ...manentlylocated manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use...

Страница 2: ...LOG PLACEMENT 11 OPERATING GUIDELINES 12 LIGHTING INSTRUCTIONS 13 PILOT FLAME CHARACTERISTICS 14 MAIN BURNER FLAME CHARACTERISTICS 15 WIRING 16 17 MAINTENANCE 17 TROUBLESHOOTING 18 19 HOW TO ORDER RE...

Страница 3: ...and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same...

Страница 4: ...sorborabsorbontoorintowalls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the...

Страница 5: ...r your gas company before changing spud ori ce size AlwaysconsultyourlocalBuildingDepartmentregardingregulations codes or ordinances which apply to the installation of an unvented room heater This app...

Страница 6: ...e air 3 Do not use an unvented room heater as the primary heat source an entire house WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Model VFP30CA30 B F M S W Input BTU HR KW H Maximum 32 000 9 4 B...

Страница 7: ...et in width and 8 feet in height the area is 1 632 cubic feet The VFP30 can be installed in this uncon ned space with no requirement to provide additional combustion and ventilation air PROVISIONS FOR...

Страница 8: ...th Schedule 40 Pipe Inside Diameter Tubing Type L Outside Diameter Nat L P Nat L P 0 10 feet 0 3 meters 1 2 12 7 mm 3 8 9 5 mm 1 2 12 7 mm 3 8 9 5 mm 10 40 feet 4 12 meters 1 2 12 7 mm 1 2 12 7 mm 5 8...

Страница 9: ...vicing and proper operation must be provided Installation on Rugs and Tile Thisappliancemustbeinstalledona at solid continuoussurface e g wood metal concrete This may be the oor or it may be raised up...

Страница 10: ...r shutter 9 Tighten the two 2 nuts back down locking the air shutter in place Be sure that the air shutter is the same distance from the burner ori ce on both sides of the air shutter for proper burne...

Страница 11: ...th toe resting on the groove in the left front log 12 Place right twig onto right side pin on rear log with toe resting all the way to the right on the right front log 13 Align and place top of glass...

Страница 12: ...ter please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below 1 Know what type of ignition system this model has standing pilot and follow...

Страница 13: ...r If you smell gas STOP Fol low B in the safety information above on this plate If you do not smell gas go to the next Step 7 Find pilot The pilot is attached to the main burner behind the front log 8...

Страница 14: ...ools the heater will shut down Correct Pilot Flame Pattern Figure 11 Incorrect Pilot Flame Pattern Figure 12 If pilot ame pattern is incorrect as shown in Figure 12 See Troubleshooting pages 18 and 19...

Страница 15: ...should clean dust lint and any light accumulation from the logs and the rebox area An extra soft brush should be used on the logs and burner as they are extremely fragile a vacuum cleaner may be used...

Страница 16: ...er that is a component in the FREC Turn the ON OFF REMOTE switch on the wire channel to the REMOTE position Follow instructions in the FREC to complete installation Note If electric 120 volt fails in...

Страница 17: ...shown for proper main burner ame pattern Figure 14 If it appears abnormal call a service person Verify proper operation after servicing MAINTENANCE Figure 18 WIRING continued Figure 17 REMOTE OFF ON S...

Страница 18: ...a Main burner ori ce clogged Clean main burner or replace main burner ori ce b Main burner ori ce diameter is too small Replace main burner ori ce c Inlet gas pressure is too low Contact local gas co...

Страница 19: ...s a Not enough fresh air is available Open window and or door for ventilation b Low line pressure Contact local gas company c ODS pilot is partially clogged Clean ODS pilot 14 Gas odor even when contr...

Страница 20: ...84 ORIFICE 35 NAT 13 P 250 ORIFICE 1 65mm LPG 14 24215 AIR SHUTTER BRACKET NAT 14 24430 AIR SHUTTER BRACKET LPG 15 24041 FIREBOX BOTTOM 16 15977 VALVE BRACKET 17 24024 TUBING ASSEMBLY VALVE TO BURNER...

Страница 21: ...24214 2 1008 Page 21 PARTS VIEW 26 27 28 29 30 31 1 3 4 5 6 7 8 9 10 32 33 34 2 7 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 35...

Страница 22: ...4 R 9568 CASTING TOP 5 R 9681 CASTING FRONT 6 R 9567 CASTING SIDE RIGHT 7 R 9566 CASTING SIDE LEFT 8 R 9683 CASTING DOOR RIGHT 9 R 9682 CASTING DOOR LEFT 10 24191 FIREBOX SUPPORT BRACKET 2 REQUIRED 1...

Страница 23: ...24214 2 1008 Page 23 2 3 9 4 5 6 7 8 10 10 1 11 11 11 11 13 12 12 13 CASTING PARTS VIEW...

Страница 24: ...to remove side shelf supports prior to removing cast iron top to eliminate potential scratching or chipping to the cast iron sides Note Due to inherent properties of the casting process non com busti...

Страница 25: ...allow fan control bracket to slide into slot 6 Route fan control wires through rectangular notch on wire channel left 7 Attach 1 4 push on terminal from blue wire on the fan control to the AUTO top t...

Страница 26: ...external electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded thr...

Страница 27: ...DEX NUMBER PART NUMBER DESCRIPTION 1 R 1454 BRASS BUSHING 2 R 1499 RUBBER GROMMET 3 24231 BLOWER HOUSING 4 R 1410 STRAIN RELIEF BUSHING 5 R 9927 BLOWER ASSEMBLY 6 24225 BLOWER COVER 7 R 6159 CORD SET...

Страница 28: ...24214 2 1008 Page 28 SERVICE NOTES...

Страница 29: ...24214 2 1008 Page 29 SERVICE NOTES...

Страница 30: ...24214 2 1008 Page 30 SERVICE NOTES...

Страница 31: ...ance the following minimum clearances to combustible construction must be maintained Top of appliance ceiling 36 inches Heater Corners 45 angle to Wall 4 inches Rear Wall 2 inches Floor 0 inches Side...

Страница 32: ...Page 32 EMPIRE EMPIRE Comfort Systems Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empir...

Отзывы: