Log sets comply with ANSI Z21.11.2 Unvented Heaters 

and also comply with ANSI Z21.60 Decorative Vented 

Appliances for Solid Fuel Burning Fireplaces. State or 

local codes may only allow operation of log sets in a 

vented configuration. Check your state or local codes.

DRIFTWOOD

 �

WARNING

FIRE OR EXPLOSION HAZARD

If the information in these instructions is 

not followed exactly, a fire or explosion 

may result causing property damage, 

personal injury or loss of life. 

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

WARNING

If not installed, operated and maintained in 

accordance with the manufacturer's instruc-

tions, this product could expose you to sub

-

stances in fuel or from fuel combustion which 

can cause death or serious illness.

INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

Please See Our Website For Log Assembly Videos.

LOG SET FOR UNVENTED 

GAS LOG HEATER OR VENTED 

DECORATIVE APPLIANCE

MODELS     

LS18CD-1    LS24CD-1

LS30CD-1

GAS-FIRED

LS24CD Shown

Содержание LS18CD-1

Страница 1: ...switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your g...

Страница 2: ...4 LS 18 24 30 CD Log Sets 5 Log Identification LS18CD 6 Log Placement LS18CD 7 16 Log Identification LS24CD 17 Log Identification LS30CD 18 Log Placement LS 24 30 CD 19 30 Ember Placement LS 18 24 30...

Страница 3: ...tion Properly installed and properly maintained log sets do not deposit soot on the logs If users see soot on a log they should call for service Do not continue to operate the log set Sunken Fireplace...

Страница 4: ...e Check for an open flue and adequate combustion air into the room A damper clamp must be installed on the firebox damper to maintain an open flue vent condi tion Refer to fireplace owners manual INST...

Страница 5: ...38616 0 0218 Page 5 LS 18 24 30 CD LOG SETS LS24CD LOG SET LS30CD LOG SET LS18CD LOG SET...

Страница 6: ...IPTION TOP VIEW FRONT VIEW R12544 Rear Left Log A R12545 Rear Right Log B R12546 Front Left Log C R12547 Center Log D R12548 Front Right Log E R12549 Side Left Log F R12550 Top Left Log G R12551 Side...

Страница 7: ...alled onto an unvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowing embers per the ember placement section of this...

Страница 8: ...38616 0 0218 Page 8 1 Place Log B onto right rear pin on rear log support LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 9: ...38616 0 0218 Page 9 2 Place Log A onto left rear pin on rear log support LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 10: ...38616 0 0218 Page 10 3 Place Log C onto two 2 left front pins on burner pan LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 11: ...ace the T shaped end of Log D onto the recess on Log B matching and covering the red dots and the other end of Log D onto the recess on Log C matching and covering the red dots LOG PLACEMENT LS18CD CO...

Страница 12: ...38616 0 0218 Page 12 5 Place Log E onto two 2 right front pins on burner pan Verify red dot on top of Log D is covered LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 13: ...38616 0 0218 Page 13 6 Place Log F off the left side of the burner and onto the left end of Log C matching and covering the red dots LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 14: ...38616 0 0218 Page 14 7 Place Log G onto recess on the left end of Log A and against the left side of Log F matching and covering the red dots LOG PLACEMENT LS18CD CONT D TOP VIEW FRONT VIEW...

Страница 15: ...ce the top of Log H onto the recess on the right side of Log B and place the base of the twig of Log H onto the knob on the back right of Log E matching and covering the red dots LOG PLACEMENT LS18CD...

Страница 16: ...38616 0 0218 Page 16 LOG PLACEMENT LS18CD CONT D 9 Log placement is complete TOP VIEW FRONT VIEW...

Страница 17: ...R12511 Rear Left Log A R12512 Rear Right Log B R12513 Front Left Log C R12514 Center Log D R12515 Front Right Log E R12516 Top Left Log F R12517 Top Center Log G R12518 Front Top Left Log H R12519 Si...

Страница 18: ...R12554 Rear Left Log A R12555 Rear Right Log B R12556 Front Left Log C R12557 Center Log D R12558 Front Right Log E R12559 Top Left Log F R12560 Top Center Log G R12561 Front Top Left Log H R12562 Si...

Страница 19: ...The following WARNING applies when log set is installed onto an unvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowi...

Страница 20: ...38616 0 0218 Page 20 LOG PLACEMENT LS 24 30 CD CONT D 1 Place Log A onto left rear pin on rear log support FRONT VIEW TOP VIEW...

Страница 21: ...38616 0 0218 Page 21 FRONT VIEW TOP VIEW LOG PLACEMENT LS 24 30 CD CONT D 2 Place Log B onto right rear pin on rear log support...

Страница 22: ...38616 0 0218 Page 22 LOG PLACEMENT LS 24 30 CD CONT D 3 Place Log C onto two 2 left front pins on burner pan FRONT VIEW TOP VIEW...

Страница 23: ...38616 0 0218 Page 23 LOG PLACEMENT LS 24 30 CD CONT D 4 Place Log E onto two 2 right front pins on burner pan FRONT VIEW TOP VIEW...

Страница 24: ...t end of Log E slightly and slide Log D under the end and onto the recess on right end of Log C Verify the red dot on the center of Log D is covered by the left end of Log E Verify the notch on the bo...

Страница 25: ...ACEMENT LS 24 30 CD CONT D 6 Place the top of Log F onto recess on the left end of Log A matching and covering the red dots on both logs Place the notch on the front bottom of Log F onto the 2nd burne...

Страница 26: ...d end of the Log G onto the recess on the top of Log B matching and covering the red dots and rest the back left end of Log G onto the rear log support Place the front of Log G onto the recess on the...

Страница 27: ...LS 24 30 CD CONT D 8 Place Log H onto the recess on the front of Log F matching and covering the red dots Place the right end of Log H onto the red dot step on the back of Log D matching and covering...

Страница 28: ...38616 0 0218 Page 28 LOG PLACEMENT LS 24 30 CD CONT D 9 Place Log I off of the left side of the burner and onto the left end of Log C matching and covering the red dots on each log FRONT VIEW TOP VIEW...

Страница 29: ...D CONT D 10 Place the top of Log J onto the recess on the right side of Log B matching and covering the red dots Place the base of the twig of Log J onto the knob on the back right of Log E matching a...

Страница 30: ...38616 0 0218 Page 30 LOG PLACEMENT LS 24 30 CD CONT D 11 Log placement is complete FRONT VIEW TOP VIEW...

Страница 31: ...38616 0 0218 Page 31 EMBER PLACEMENT LS 18 24 30 CD Do not cover any large rear ports with glowing embers Do not cover any large front ports with glowing embers Area for glowing embers...

Страница 32: ...tching and covering the red dots on logs Refer to log placement LS18CD on page 14 if needed LS18CD On Manual Burner LS 24 30 CD 1 To operate the valve on an 24 or 30 inch burner it may be neccessary t...

Страница 33: ...38616 0 0218 Page 33 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 34: ...38616 0 0218 Page 34 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 35: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 36: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Отзывы: