background image

R1595-1-0519

Page 1

Empire Comfort Systems Inc. • Belleville, Il.

The vinyl siding vent kit allows the owner to extend the vent cap away from vinyl siding. The vinyl siding vent cap extension protects vinyl 

siding from possible warpage or discoloration.

new installation

1.  Measure existing wall depth plus 3" for vinyl siding vent cap extension. EXAMPLE: 6" wall depth plus 3" vinyl siding vent cap exten-

sion, total depth is 9".

 

ATTENTION: When using the DV-822 vinyl siding vent kit, do not exceed the maximum depth of:

 

10" for Model Number DVC-35(SPP/IP) (7" wall plus 3" depth for DV-822)

 

13" for Model Number DV-210-(7,9)SG/215-(7,9)SG, DV-25-(1,2)SG, DV-35-(1,2)SG, DVC-55(SPP/IP) (10" wall plus 3" depth for DV-822)

2.  Install furnace according to Installation Instructions and Owner’s Manual.

3.  After cutting hole through outside wall, attach vinyl siding vent cap extension to outside wall.

4.  Attach vent tubes, outside mounting plate, and vent cap according to Installation Instructions and Owner’s Manual.

5.  Installation is complete.

existing installation

1.  Remove vent cap and outside mounting plate.

2.  Measure existing wall depth plus 3" for vinyl siding vent cap extension. EXAMPLE: 6" wall depth plus 3" vinyl siding vent cap exten-

sion, total depth is 9".

 

ATTENTION:  When using the DV-822 vinyl siding vent kit, do not exceed the maximum depth of:

 

10" for Model Number DVC-35(SPP/IP) (7" wall plus 3" depth for DV-822)

 

13" for Model Number DV-210-(7,9)SG/215-(7,9)SG, DV-25-(1,2)SG, DV-35-(1,2)SG, DVC-55(SPP/IP) (10" wall plus 3" depth for DV-822)

3.  If wall depth allows the use of the vinyl siding vent cap extension, please order a new flue tube and air tube.  The existing tubes will 

be too short with the addition of the vinyl siding vent cap extension.

 

waRning:

 Do not attempt to add sections of pipe to the flue tube and air tube. An air tight seal is required for both tubes. Only use Empire 

Comfort Systems, Inc. flue tube and air tube. 

4.  With a new flue tube and air tube, remove existing tubes.

5.  Attach vinyl siding vent cap extension to outside wall.

6.  Attach vent tubes, outside mounting plate, and vent cap according 

 

to Installation Instructions and Owner’s Manual.

7.  Installation is complete.

Part number

Description

TH-109

3" Flue Tube DV-210/215

TH-107

5" Air Tube DV-210/215

DV-524

4" Flue Tube DV-25/35/DVC-55

DV-548

6" Air Tube DV-25/35/DVC-55

DV-870

4" Flue Tube DVC-35

DV-871

6" Air Tube DVC-35

installation instRUCtions

DV-822 VinYl siDing Vent Kits

Vent Kits PaRts list

Part number

Description

DV-819

 

Vent Cap Extension (Aluminized Steel/Aluminum Paint)

Screws (8 Required) - #10 x 1-1/2 inch

R-1595

Vent Kit Instructions