background image

 

 

1

 

TILTING PAN (GAS) 

 

 

 

 

Kasap Tip Dik Buzdolapları 

 

 

 

 

 

CONTENTS 

GENERAL INFORMATION 

Page  2

 

A1 

PRODUCT DESCRIPTION 

Page 

A2 

TECHNICAL INFORMATION 

Page 

A3 

TRANSPORTATION 

Page 

A4 

UNPACKING 

Page 

INSTALLATION 

 

 

 

 

Page  4 

SAFETY INSTRUCTIONS 

 

 

 

Page  5

 

OPERATION   

 

 

 

 

Page  6

 

CLEANING & MAINTENANCE  

 

 

Page  7 

TROUBLESHOOTING   

 

 

 

Page  8 

INJECTOR CHANGE AND GAS SETTING 

 

Page  9 

GAS CONNECTION IMAGES   

 

 

Page  10

 

SPARE PART LIST- EXPLODING DRAWING   

Page  12

 

 

 

 

Содержание EMP.DTG.120

Страница 1: ... TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 3 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G INJECTOR CHANGE AND GAS SETTING Page 9 H GAS CONNECTION IMAGES Page 10 I SPARE PART LIST EXPLODING DRAWING Page 12 ...

Страница 2: ...isobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off the a...

Страница 3: ... DTG 50 800x730x850 125 900x960x1150 EMP DTG 80 800x900x850 145 820X1020X1040 EMP DTG 120 1200x900x850 215 1330x1170x1150 A2 TECHNICAL INFORMATION Product Code Capacity lt Power KW Gas Consumption NG Gas Consumption LPG EMP DTG 50 50 13 0 8 m h 0 6 kg h EMP DTG 80 80 21 1 0 m h 0 7 kg h EMP DTG 120 120 30 1 1 m h 0 8 kg h A3 TRANSPORTATION This appliance can not be moved by hand from area to area ...

Страница 4: ... appliance is must have enough ventilation and vent hole The appliance must be connected correctly according to local and national gas standards of your country The appliance gas entrances are indicated with G label on the body Connection to gas fitment must be done with suitable diameter metal flex pipe and spheric valve The spheric valve must be immobilized to a place that is far away from heat ...

Страница 5: ... machine is empty Do not load so less or more than appliance s capacity Do not attempt to use the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire If there is gas leakage where the applianc...

Страница 6: ...lowly and turn it to left Provide the gas flow to the pilot by keeping it pressed Fire the pilot In order to see the pilot and the flame at burner observe it from flame observation hole that is at the appliance s front panel After the pilot is fired provide the burner to burn by turning gas control valve to clockwise Provide the cooking pan to be placed smoothly Get ready the materials that are de...

Страница 7: ...ure water Do not clean the appliance with a materials that may damage chrome material Pay attention the pilot group not to contact with water during use and cleaning PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person These parts Gas storage pilot thermocouples taps burner lighter and spark plug cable are not maintained so they need to be changed when they have error C...

Страница 8: ...RE NOT COOKED WELL 1 Check if it is operated at suitable gas setting or not 2 Do not overload the cooking pan THE APPLIANCE STOPPED 1 The appliance s thermostat control stops the gas automatically when it reaches desired temperature 2 If the flame is out involuntarily during the operation safety valve will stop the gas automatically through the agency of thermostat If cooking at tilting pans is no...

Страница 9: ...40 2 5 2 5 50 mbar 1 40 2 5 2 5 Change of Burner Injector 1 Rip off the injector at the entrance of burner with a suitable tool 2 Change A injector by paying attention to the datas at chart with suitable injector Image 1 3 Adjust the burner entrance setting F by loosening B bolt and moving the valve to forward back Image 2 4 Change C injector by paying attention to the datas at chart with suitable...

Страница 10: ...10 TILTING PAN GAS Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 2 Image 1 ...

Страница 11: ...11 TILTING PAN GAS Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 3 ...

Страница 12: ...12 TILTING PAN GAS Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Страница 13: ...P DTG 50 007 8 BUTTON Y EMP DTG 50 008 9 GAS TAP Y EMP DTG 50 009 10 ADJUSTMENT HANDLE Y EMP DTG 50 010 11 BURNER Y EMP DTG 50 011 12 SPARKING PLUG CABLE Y EMP DTG 50 012 13 INJECTOR GROUP Y EMP DTG 50 013 14 PILOT Y EMP DTG 50 014 15 THERMO PART Y EMP DTG 50 015 16 PAN Y EMP DTG 50 016 17 YELLOW NUT Y EMP DTG 50 017 18 SHAFT Y EMP DTG 50 018 19 BEARING BLOCK Y EMP DTG 50 019 20 FLEX HOSE 100CM Y ...

Страница 14: ...P DTG 80 007 8 BUTTON Y EMP DTG 80 008 9 GAS TAP Y EMP DTG 80 009 10 ADJUSTMENT HANDLE Y EMP DTG 80 010 11 BURNER Y EMP DTG 80 011 12 SPARKING PLUG CABLE Y EMP DTG 80 012 13 INJECTOR GROUP Y EMP DTG 80 013 14 PILOT Y EMP DTG 80 014 15 THERMO PART Y EMP DTG 80 015 16 PAN Y EMP DTG 80 016 17 YELLOW NUT Y EMP DTG 80 017 18 SHAFT Y EMP DTG 80 018 19 BEARING BLOCK Y EMP DTG 80 019 20 FLEX HOSE 100CM Y ...

Страница 15: ... 120 007 8 BUTTON Y EMP DTG 120 008 9 GAS TAP Y EMP DTG 120 009 10 ADJUSTMENT HANDLE Y EMP DTG 120 010 11 BURNER Y EMP DTG 120 011 12 SPARKING PLUG CABLE Y EMP DTG 120 012 13 INJECTOR GROUP Y EMP DTG 120 013 14 PILOT Y EMP DTG 120 014 15 THERMO PART Y EMP DTG 120 015 16 PAN Y EMP DTG 120 016 17 YELLOW NUT Y EMP DTG 120 017 18 SHAFT Y EMP DTG 120 018 19 BEARING BLOCK Y EMP DTG 120 019 20 FLEX HOSE ...

Отзывы: