Identification
© 2020, EMP Inc.
13
EMP Oil Pump Model Codes
Example:
OP3530-24V-EA-M
OP 35 30 - 24V - E A - M [OEM] [Cert] [Suffix]
1
2
3 4
5
6
7 8 9
10
11
12
1
Component
OP = Oil Pump
5
Voltage
9
I/O
Omit if n/a
A = Address Input
C = Temperature Input
B = Address or Temp Input
(Specified in Calibration)
P = Pressure
M = PWM High (modulated)
L = PWM Low (modulated)
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
2
Scavenge Flow Rate
In 0.1 gallons per minute
35 = 3.5 gpm (13.2 lpm)
Omit for single stage pumps
6
Mounting
E = External Mount
C = Cartridge Mount
10
OEM
Omit if n/a
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
3
Pressure Flow Rate
In 0.1 gallons per minute
30 = 3.0 gpm (11.4 lpm)
40 = 4.0 gpm (15.1 lpm)
80 = 8.0 gpm (30.3 lpm)
7
Orientation (degrees)
A = 0
B = 90
C = 180
D = 270
See manual for definition
11
Certification
Omit if n/a
E = E-Mark
C = CSA
U = UL
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
4
Communication
C = CAN
Omit for on/off or PWM
8
Relief Valve Cracking
Pressure
Omit if n/a
05 = 5 psi
15 = 15 psi
25 = 25 psi
30 = 30 psi
70 = 70 psi
12
Suffix
Omit if n/a
Denotes model variation
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
OP3530-24V-EA-M
= Oil Pump. 3.5 gpm scavenge/3.0 gpm pressure, on/off/PWM communication, 24 Volt
External Mount at 0 degrees, no relief valve, uses PWM High input for commands.
NOTE:
Not every option combination is available.
NOTE:
All current pump models are optimized for use with lighter weight oils like ATF. Performance will be
reduced for heavier weight oils.