Dear Customer
Congratulations on the purchase of the EMP-Centauri Profi Class product. Before its installation and putting into
operation, read carefully the entire operation manual. Keep the operation manual in a safe place. The product
may only be installed and connected with strict observance of the manual and of valid regulations.
The area of application, warranty
The product is designed for distributing satellite, terrestrial TV and radio signals for in normal house installations.
The warranty shall not apply, if the product is used for other than specified purpose. The user will be responsible
for injury or material damage which may arise in consequence of any use of the product in contradiction with
the manual. The product utilizes technologies which are protected by copyrights and patents. It is prohibited and
unlawful to dismantle the product and make any interventions in it.
EMP-Centauri Profi Class products are covered under warranty for up to 4 (four) years from the date of
manufacturing. To enable superior warranty and post service warranty service, keep all purchase records in a
safe place. It is also recommended to keep the original packaging for the warranty period.
Product installation
Products are possible to use outdoor, placing into vertical position, with the connectors down.
To connect inputs and outputs, use quality coaxial cable 75Ω with F connectors, which are designed for satellite
reception. It is not allowed to break coaxial cables, minimal bend radius is 5 cm. Tighten the F connectors with
adequate power. Examples of practicable connections are shown in this manual or at www.emp-centauri.cz.
Technical specification of product
Frequency range: terrestrial band (TERR) 5-862MHz, satellite band (SAT) 950-2300MHz
Insertion Loss – C2/1PNP(T+S)-W1, C2/1PNP(T+S)5V-W1: 1 dB typ. (5-862 MHz), 2 dB typ. (950-2300 MHz)
Insertion Loss – C3/2PNP(T+2S)-W1: 5 dB typ. (5-862 MHz), 2 dB typ. (950-2300 MHz)
Insertion Loss – C5/4PNP(T+4S)-W2: 8 dB typ. (5-862 MHz), 5 dB typ. (950-2300 MHz)
Terr. Preamplifier Power (C2/1PNP(T+S)5V-W1): 100 mA / 5 V