background image

 

 

Instruction elliptical trainer 900 / 900 med

 

Version 1.1 07.06.2022

 

Page 6 from 13 

 

 

Warning: 

The heart rate monitoring system is susceptible to failure due to the system. Excessive exercise can 

lead  to  dangerous  injuries  or  death.  If  you  feel  unwell,  stop  exercising  immediately  and  consult  your  doctor  or 
therapist. 

 

Warning: The 

unit may only be operated with a housing and in dry rooms. 

 

Warning  for  optional  power  connection: 

Use  only  approved  power  supply  units  that  have  been  tested 

according to IEC 60601-1 and approved by the unit manufacturer. Make sure that the power supply is installed in 
such a way that it is difficult to disconnect it (e.g. by means of floor tanks, installation under the unit or cable ducts, 
position of the power supply in areas that are difficult to access). 

 

Warning: 

If the medical device is modified, appropriate investigations and tests must be carried out to ensure 

continued safe use. Do not modify the device without the permission of the manufacturer. 

Indications and contraindications 

Before starting training, please consult a doctor or therapist to ensure fitness for training.  

 

Example indications 

  Mobility of the musculoskeletal system  

  Strengthening the musculature  

  Strengthening the cardiovascular system  

Example contraindications 

  Cardiovascular diseases  

  Pain of the musculoskeletal system  

  During the training:  

o

  Chest pain  

o

  Malaise 

o

  Nausea 

o

  Dizziness  

o

  Shortness of breath 

Ask the doctor if you are taking medication. 

Содержание motion cross 900

Страница 1: ...Instruction elliptical trainer 900 900 med Version 1 1 07 06 2022 Page 1 from 13 Instructions for use for motion cross 900 motion cross 900 med...

Страница 2: ...ning 5 Indications and contraindications 6 4 Operating the display 7 Overview display key functions 7 Pulse systems 8 Inductive charging optional 8 5 Care maintenance and servicing 8 Instructions for...

Страница 3: ...n the joints affected during training The equipment enables reproducible physical loading of the human body and the cardiovascular system for the purposes of prevention rehabilitation and diagnosis Te...

Страница 4: ...stallation of the equipment Fig 1 Side view of the unit with designation of the essential elements Adjustable feet for levelling Pedals Position name plate Rigid hand grips for support during lower li...

Страница 5: ...n training tight fitting lightweight sports clothing is preferable so that it cannot get caught in parts of the device during training Always wear suitable sports shoes for a secure footing on the ped...

Страница 6: ...o disconnect it e g by means of floor tanks installation under the unit or cable ducts position of the power supply in areas that are difficult to access Warning If the medical device is modified appr...

Страница 7: ...se the key or key to increase or decrease the parameters or power values to be set Use the arrow keys to navigate through the corresponding menus and confirm values or settings Swipe swipe gestures na...

Страница 8: ...arging optional An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med units via the connect package This allows mobile devices that comply...

Страница 9: ...imitation ISO 7010 W001 General warning sign ISO 7010 M002 Follow the operating instructions IEC 60417 5840 Type B applied part concerns saddle pedals and handlebars The safety level of the units can...

Страница 10: ...rom the PC after the specified time period Restart the PC and plug the USB dongle into the PC again If necessary restart the software service All ergometers Radio Problem verbos The unit does not rece...

Страница 11: ...h a damp cloth and mild soap then wipe dry again The use of spray bottles with cleaning agents is not permitted it has been shown that the units never become dry in inaccessible places Rust infestatio...

Страница 12: ...and regulations at the location of the units Your local authorised dealer can also provide further information 6 Technical data Device type Dimensions L W H Weight Max user weight Safe workload motion...

Страница 13: ...e of service The following procedures are conceivable 1 the service is carried out on site by our service 2 we send the desired spare part 3 we will send a replacement unit The defective parts shall b...

Отзывы: