4
AL
P
0
3
M0
0
0
1
MB
0
2
3
3
1
2
D
4
2
5
0
3
1
4
centre e.g. a circulating pump.
Terminals
L2
and
N2
are the 230V~ powered
outputs for connecting the circulating pump.
Terminals
NO
and
C
are the output for the boiler
control. This is a voltage free contact (i.e.
unpowered) so that they can be used for boilers
with different voltages.
Through terminals
L1
N1 SWL NSB
a 230V~
external timeswitch (optional) can be connected to
the wiring centre. Terminals
L1
and
N1
are the
powered outputs for the timeswitch power supply,
while
SWL
and
NSB
are the lines provided for
powering the actuators and thermostats section.
For complete control of each of the available
channels the user must connect a 230V~ actuator
to terminals
L1
and
N1
and a 230V~ thermostat to
terminals
NSB SwL< SwL> TN TL
. All outputs of
the actuators and thermostats section are 'powered'
outputs, i.e. they do provide the voltage for the
device connected to them.
Note: Each of the eight wiring channels has
terminals for one thermostat and one actuator only.
Up to five actuators can be connected to a channel
by using a loose cap terminal, code U9360030,
available from Emmeti UK Ltd.
TECHNICAL FEATURES
Power supply:
230V~ ±10% 50Hz
Absorption:
Depends on the loads
connected.
Fuse (
F1
):
8A Time delayed
Pump output:
Powered contact
Boiler output:
Voltage free contact
Therm./actuators outputs:
230V~
Time prog. output (optional): 230V~
Contacts rating:
- Pump:
5A@250V~ SPDT
- Boiler:
1A@250V~ SPDT
- Actuators and thermostats: 8x1A@250V~
Maximum applicable load:
- Actuators and thermostats: 2,5A Total
1A each channel
Indicators:
- Voltage presence:
Green led
- Boiler and pump activation: Red led
Protection index:
Operating temp.:
Storage temp.:
Humidity limits':
Case:
Material:
Colour:
Dimensions:
Weight:
IP 30
0 .. 40 °C.
-10 .. 50 °C
20% .. 80% RH
(non condensing)
ABS UL-V0
self-extinguishing
Signal white
(RAL 9003)
245 x 100 x 60 mm
(W x H x D)
~
520
gr.
WARRANTY
In view of the constant development of their
products, the manufacturer reserves the right for
changing technical data and features without prior
notice. The consumer is guaranteed against any
lack of conformity according to the European
Directive
1999/44/EC
as
well
as
to
the
manufacturer’s document about the warranty policy.
The full text of warranty is available on request from
the seller.
1
AL
P
0
3
M0
0
0
1
MB
0
2
3
3
1
2
A4
2
5
0
3
1
4
U9370001
EWC-2 8 WAY WIRING CENTRE 230V
•
230V~ power supply and outputs
•
Connections for up to 8 separate heating zones
•
Pump output and interlock boiler output
•
Each channel has terminals for one thermostat and actuator
•
External timeswitch input (optional)
•
Compliant with directives EEC 2004/108 (EMC), 2006/95 (LVD)
and 2011/65 (RoHS2)
6 Tannery Yard - Witney Street - Burford
Oxfordshire - OX18 4DW - UK
Phone: 01993 824900
Fax: 01993 824990
Email: [email protected]
Website: www.emmeti.co.uk
UK
Fig. 3:
Cable entry instructions
Fig. 1:
External aspect
Fig. 2:
Internal view and parts
2
2
226 mm
245 mm
1
0
0
m
m
11 mm
5
5
m
m
2
6
,5
m
m
3
4
Wiring Centre
EWC-2 8-Way
1
1
1
1
1
B
A