background image

See overleaf for further setting up information

Sensor selection. This thermostat is a combination model allowing you to choose

between 4 different models. (A, AF,F )

A  model:      air only, with built in sensor

AF model:   air & floor , with both built in and remote sensor

F model:      floor only, with remote sensor

Configuration Menu

Turning ON/OFF Your Thermostat

Press  buttton             to turn the thermostat ON or OFF. When thermostat is turned off, LCD will display OFF. 

This thermostat is full of useful features which can be set quite easily through the feature configuration menu. To access the feature configuration menu, simply turn off your thermostat

and hold button M for 5 seconds. Now you can see Menu 1, to proeceed to other menu, press button M again. To exit menu, press button

Menu #

 1

Switching differential.

Calibrate the room temperature. This feature is used to compensate for any difference

Calibrate the floor temperature. This feature is used to compensate for any  difference

Set the floor temperature limit.

Set backlight turning-on time.  Selecting on will turn the light on continuously.

Selecting off will turn the light off. Selecting 20 seconds will turn the light on for 20 seconds.

Select temperature format  

Optimum start(preheat). This feature is to ensure that the required temperature has

already been reached when you get up in the morning or come home from work.

Select 12 / 24 hour clock

24  

12 / 24  

Pump protection(for hydronic heating only).  In hydronic heating installations, it is 

recommended to activate the pump at least 15 seconds every 24 hours in order to

avoid any seizing.  Select ON to activate this feature, OFF to deactivate. When the

thermostat is activating the pump, the        icon will blink.

2

3

4

5

6

7

8

9

10

11

12

Feature Description

Factory Default

Feature Value

0°C

OFF

ON / OFF

ON / OFF

 OFF

7_0

5_2  /  6_1  /  7_0

OFF

ON / OFF

40 °C

20°C ~ 40 °C

   20 seconds   

   20 seconds / ON /OFF   

  °C / °F

  °C

A / AF / F 

Press         or          to select

This product should be installed by a qualified electrician.

The number of degrees difference between switching off at the 

between the displayed room temperature  and a thermometer.  

between the displayed floor temperature  and a thermometer.  

This feature is to protect the floor surface.

 °C or °F. 

Buttons and LCD display

Buttons

Short press 

Press > 5 seconds

Turning on/off thermostat

Menu button( when thermostat is turned off) 

Auto/Manual mode selection

Increase the set value

Bring up vacation mode

Check floor temperature (AF model only)

Decrease the set value

Lock /unlock buttons

Reset to factory settings

(when thermostat is turned off) 

+

+

Set the time and week days

Cancel override( when in override mode)

Confirm settings

M

M

The buttons are locked.

Displays when heating is active

Symbol

Description

Auto mode(use button M to select)
Manual mode(use button M to select)

Vacation mode

Temporary temperature override

Frost protection activated

Set temperature

The program number

Program 1,2,

         3,4,5,6

AUTO

SET AT

Program type selection. This gives user 3 options of program type. 

5_2 

will give you 5 days(Monday to Fiday) with the same six events(Wakeup, out, home,

6_1

 will give you 6 days(Monday to Saturday) with the same six events(Wakeup, out, home,

7_0

 will give you individual settings for each day from Monday to Sunday.

out, home,sleep) and 2 days(Saturday and Sunday) with the same six events.

out,home,sleep) and 1 day(Sunday) with the same six events.

Frost protection.

This feature is to avoid room temperature going below 5°C 

E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance.

E1 = The remote floor sensor has not been connected, has been wired incorrectly or the probe is faulty.

LO = The room or floor temperature is below 0

Error

Message

°C

 

HI = The room or floor temperature is above 50 °C

 

Program button( when thermostat is turned on) 

means the thermostat will switch the heating on 0.5°C below the set temperature and 
will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch

 

on 1°C below the set temperature and switch off 1°C above the set temperature. 

 

1°C

1°C ~ 5°C

-5°C ~ +5°C

0°C

-5°C ~ +5°C

CS-11 LCD 7-Day 5+2 Programmable Digital Thermostat

U9310044

Registered Address:  6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW
Tel:  01993 824900 : www.emmeti.co.uk :  e:  [email protected]

Temporary

set temperature and  on again to reach the set temperature.The default is 1°C which    

Отзывы: