actuator-control (DiSEqC 1.2).
Even 13/18V and 22 kHz can be adjusted under the DiSEqC-
menu.
Memory
A multichannel measuring can be stored. Chose button nr 6
(Memory).
Select the memory-position where to store the data with the
main-knob (pos: 00-99) and push button nr 2 (save). The
data is stored.
Load measured data by first chosing the memoryposition
with the knob (pos: 00-99).
Push button nr 1 (load) and the memory is displayed on the
monitor.
Delete measured data by first selecting the memoryposition
to be deleted (pos:00-99) Push button nr 3 (delete) and the
data is deleted.
Digital – Analog
Use this button to step between analog and digital multi-
channel measurings. Again, 10 pages of both ana/digi-
signals with up to 10 frequencies per page can be stored.
3.8.6. Atten (6)
Attenuator 15 dB on/off.
3.8.7. 13/18V (0)
Adjusting of 13V alt. 18V. Selected position is displayed up to the left in the LCD-
display.
3.8.8. 22 kHz (#)
Adjusting of 22 kHz on/off. Selected position is displayed up to the left in the LCD-
display.