Move the cursor to any desired frequency (peak).
Push the nr 3 button (
span Min
) on the keyboard. The instrument will ”zoom in”
max. at that selected frequency (250 MHz bandwidth).
Rotate the LNB so that either the Horisontal or Vertical polarisation will be in its
max-position –adjusting the
cross-polarisation
. Pressing the nr 3 button again (span
Max), gets You back to ”Max zoom out”.
3.4. X-pol
Test the maximum Cross-pol setting with the X-pol function. The instrument will
measure the strength of the selected peak and then automatically switch to the other
polarisation and measure there as well (same frequency and settings).
The difference (for ex. -7dB) is presented on the right handside of the display. The
function is very usefull for checking the correct setting of the LNB cross-polarisation.
3.5. DiSEqC
Chose the DiSEqC command with the keypad.
Submenu 7 (SWx) shows the extended DiSEqC 1.1 commands. Submenu 8 (Motor)
shows the DiSEqC actuator-control commands (DiSEqC 1.2). Even 13/18V and 22
kHz on/off can be adjusted in this mode.