7
Fixing the cooktop
The cooktop is to be fixed to the bench as follows:
1.
Place the sealing gasket supplied along the outside edge of the hole cut into the bench
so that the ends of the strips are perfectly joined without overlapping.
2.
Position the cooktop into the hole in the bench making sure it is centered.
3.
Attach the cooktop to the bench with the supplied mounts as shown in fig. 16.
4.
When the sealing gasket is correctly installed, it will protect the cooktop from intrusion of
liquids.
Connecting the gas
The instructions are for a qualified installer.
The appliance must be installed correctly, conforming to the laws in force.
Remove the electrical power supply before servicing the appliance.
Gas Inlet Connection Point
Model SEC64 – 519mm from left hand edge of cut out, 40mm from rear edge.
Model FC64,SEC75, F74, F75 – 215mm from left hand edge of cut out, 40mm from rear edge
Model FC95 – 799mm from left hand edge of cut out, 40mm from rear edge
These technical instructions have been prepared for the use by Authorised persons. The
requirements of the local Gas and Electrical authorities must be adhered to, consult
AG601/AS5601 as appropriate.
•
Before installation, make sure that the gas type (natural gas and LPG) and the
cooktop are compatible. To do this, check the data on the product plate on the
cooktop and on this booklet.
•
Gas inlet fitting is ½” BSP (male) thread.
•
The gas connection is identified in table figure 7A.
•
Fit regulator supplied for natural gas or supplied LPG test point (as applicable)
•
It is recommended that an isolating valve and union be fitted, to enable simple
disconnection for servicing. These are to be in an accessible location.
•
Check connections are gas tight with soapy water or other approved method
Flexible Hose Connection
Install with a hose assembly that complies with AS/NZ1869 (AGA Approved). 10mm ID class
Bor D and in accordance with AS5601. This hose must not exceed 1.2m in length. Ensure that
the hose does not contact the hot surfaces of the cooktop or oven or any other appliance that
may be installed underneath or adjacent to the cooktop. The hose must not be subject to contact
from drawers, abrasion or kinking. All joints must be checked for leakage using soapy water.
Final Check
Operate the burners on high and low flames and check that each burner ignites properly and
has a stable flame. The following may be abnormal:
•
If the burners have yellow tipping
•
If the pots are sooting underneath
•
If the burners fail to ignite properly
•
If the burners fail to remain alight
When satisfied with the operation of the cooktop please explain to the user the correct method
of operation. If the appliance can not be adjusted to operate correctly refer to Glem Gas for