Appendix II
EM15 User’s Manual
126
Appendix II. Function Code Table
If A0-00 is set to a non-zero number, parameter protection is enabled. You must write in correct user password to
enter the menu.
To cancel the password protection function, enter with password and set A0-00 to 0.
The parameter menu under the user-defined parameter mode can directly enter without password.
Group “A” is frequency inverter system parameter. Group “b” is basic function parameters. Group “C” is
application parameter, Group “d” is control parameter, and Group “U” is monitoring function parameters.
The symbols in the function code table are described as follows:
"
☆
": The parameter can be modified when the frequency inverter is in stop or running state.
"
★
": The parameter cannot be modified when the frequency inverter is in running state.
"●": The parameter is the actually measured value and cannot be modified.
"*": The parameter is factory parameter and can be modified only by the manufacturer.
Standard Function Parameters
Code
Parameter Name
Functional description
Default
Property
Group b0: Basic Function Parameters
b0-00 Motor type selection
0: AC asynchronous motor
0
★
b0-01 Motor control mode
0: Sensor-less vector control (SVC)
1/2:V/F control
3: Closed-loop vector control (FVC)
2
★
b0-02 Command source selection
0: Keypad control (LED off)
1: Terminal control (LED on)
2: Communication control (LED blinking)
0
★
b0-03
Main frequency source X
selection
0: Digital setting (Digital setting frequency b0-12,
UP/DOWN modifiable, no-record after power off)
1: Digital setting (Digital setting frequency b0-12,
UP/DOWN modifiable, record after power off)
2: AI1
3: AI2
4: AI3
5: Pulse setting (HDI)
6: Multi-function
7:Built-in PLC
8: PID
9: Communication setting
1
★
b0-04
Auxiliary frequency
source Y selection
The same as b0-03 (Main frequency source X selection)
0
★
b0-05
Selection of auxiliary
frequency Y range
0: Relative to maximum frequency
1: Relative to main frequency X
0
☆
b0-06
Range of auxiliary
frequency Y
0%~150%
100%
☆