764-500 to 764-759

Gas Pilot Safety Valve 

(Thermocouple-Operated)

INSTALLATION INSTRUCTIONS

Operator:  Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 

INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 

INJURY AND/OR PROPERTY DAMAGE.

 SPECIFICATIONS

Ideal for use on wall heaters, space 

heaters, consoles, etc., this gas pilot 

safety valve provides 100% shut-off of 

both pilot and main burner gas supply 

in the event of pilot flame failure. This 

valve is equipped with a 3-position 

gas control knob to provide for pilot 

lighting. This control also allows pilot 

flame adjustment. 

If the pilot flame goes out during normal 

operation, or if there is insufficient pilot 

flame to provide proper thermocouple 

output, the safety valve will close, 

stopping the flow of all gas. This valve 

is designed for use on all domestic 

heating gasses up to ½" PSI.

Capacity (for AGA natural gas at 1" drop):
  ½" x ½"size:
   

side inlet  - 124,000 BTU/hr.

   

bottom inlet - 118,000 BTU/hr.

Pilot connection: ¼" tubing
Pressure: ½" PSI maximum
Ambient Rating: -40ºF to 250ºF operating temperature
Mounting Position: Multipoise

 DESCRIPTION

Ignition Source: Pilot 
Type of gas: Suitable for all domestic heating gasses
Thermocouple: Use W.R. Type H06E
Accessories:   Item  

 

Part No,

   

 

Replacement Knob 

F42-0895

 

 

 Stem 

Extender 

 F145-1111

Approvals: 

CSA

white-rodgers.com

emersonclimate.com

PART NO. 37-5234F

Replaces 37 -5234E

1523

DO NOT USE THESE GAS VALVES WITH 
UNVENTED APPLICATIONS

CAUTION

!

INLET

OUTLET

PILOT

OUTLET

PILOT ADJUST

COVER SCREW

THERMOCOUPLE

CONNECTION

1.19”

0.78”

0.031”

2.16”

4.66”

STRAIGHT THRU

1.55”

1.22”

GAS CONTROL KNOB

INLET

OUTLET

THERMOCOUPLE

CONNECTION

0.78”

2.50”

5.20”

OPTIONAL

INLET (PLUGGED)

DUAL INLET 

NOTE: One inlet to be plugged

GAS CONTROL KNOB

1.19”

PILOT ADJUST

COVER SCREW

1.55”

1.22”

All Dimensions are for Reference Only

Содержание White-Rodgers 764-500

Страница 1: ...gas This valve is designed for use on all domestic heating gasses up to PSI Capacity for AGA natural gas at 1 drop x size side inlet 124 000 BTU hr bottom inlet 118 000 BTU hr Pilot connection tubing Pressure PSI maximum Ambient Rating 40ºF to 250ºF operating temperature Mounting Position Multipoise DESCRIPTION Ignition Source Pilot Type of gas Suitable for all domestic heating gasses Thermocouple...

Страница 2: ...structions exactly B BEFORE LIGHTING smell all around the appliances area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbors s phone Follow...

Страница 3: ...nce de po PSI Capacité pour gaz naturel AGA à une chute de pression de 1 po format po x po entrée latérale 124 000 BTU h entrée inférieure 118 000 BTU h Connexion du pilote tube po Pression po PSI maximum Température nominale ambiante Températuresdefonctionnement 40 C à 121 C 40 F à 250 F Position de montage Multipositions DESCRIPTION Source d allumage Pilote Type de gaz Convenable pour tous les g...

Страница 4: ...entezlesenvironsdelazonedesappareilspourdétecter toute odeur de gaz Sentez à proximité du sol car certains gaz sont plus lourds que l air et se déposent sur le sol POUR VOTRE SÉCURITÉ QUE FAIRE SI VOUS DÉTECTEZ UNE ODEUR DE GAZ Ne tentez pas d allumer quelque appareil que ce soit Ne touchez à aucun interrupteur électrique n utilisez pas de téléphone dans votre immeuble Appelez immédiatement votre ...

Отзывы: