Electrical Rating: 

24 VAC, 60 Hz., 23A

Pilot Gas Outlet:

 

Located at outlet end of the valve

Type of Gas: 

Suitable for all domestic heating gases

Pressure Regulator Setting:

 

Adjustable from 2

1

2

 to 5” W.C. (Factory adjusted for 3.5” W.C.

Pressure Rating:  

1

2

 lb. per sq. in.

Ambient Temperature:

  -40° to 175°F

Mounting:

  Any position except upside-down

CAPACITY (IN BTU PER HOUR)

1

2

” x 

3

8

1

2

” x 

1

2

1

2

” x 

3

4

3

4

” x 

3

4

162,000
372,600
372,600
453,600

100,000
230,000
230,000
280,000

NATURAL GAS

(1000 Btu/Cu. Ft.

0.64 Sp. Gr.)

LP GAS

(2500 Btu/Cu. Ft.

1.53 Sp. Gr.)

 INLET BOSS
UP OR DOWN

   UPRIGHT

 LEFT OR RIGHT

Upright, 90

°

 from upright or vertical

NOTE:

 Control shown may not be identical to replacement control.

ON

OFF

INSTALLATION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY 
AND/OR PROPERTY DAMAGE.

This multi-function gas controls combines into a single compact 
package the functions of 3-position gas cock, a main gas valve and 
a pressure regulator. The pilot outlet is plugged, but will accept a 

1

4

” 

pilot line connection. This control can be mounted in any orientation 
except upside down.
To permit replacement of a variety of valve sizes, this control is 
furnished with three reducer bushings (two 

3

4

” to 

1

2

” and one 

1

2

” to 

3

8

”). Also included is a conversion kit which allows this valve to be 

used at regulator settings of 4.2” W.C. to 11.0” W.C.

Operator: Save these instructions for future use!

36C01

Combination Gas Valves

(24 Volt and 120 Volt Models)

OFF

PILO

T

ON

MODELS AVAILABLE

Model No.

Voltage

36C01

36C01A

Current

.23 Amp

.035 Amp

24 volts

120 volts

Gas

Nat.
Nat.

 

 DESCRIPTION

 

 SPECIFICATIONS

PART NO. 37-5870C

Replaces 37-5870B

1333

www.white-rodgers.com

www.emersonclimate.com

Содержание White-Rodgers 36C01

Страница 1: ...RE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE This multi function gas controls combines into a single compact package the functions of 3 position gas cock a main gas valve and a pressure regulator The pilot outlet is plugged but will accept a 1 4 pilot line connection This control can be mounted in any orientation except upside down To permit replacemen...

Страница 2: ...r gas leaks with leak detection solution or soap suds Bubbles forming indicate a leak SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY Horizontal Drop Piped Gas Supply Gas Valve 3 in minimum Gas Valve Riser Piped Gas Supply 3 in minimum Drop Horizontal Riser Gas Valve Tubing Gas Supply 3 in minimum NOTE Always Include A Drip Leg In Piping Figure 1 Typical gas valve piping DO NOT BEGIN INSTALLATION UNTIL...

Страница 3: ...ausing the flame sensor bulb to sense low heat To adjust the pilot gas pressure remove the cover screw see fig 5 To REDUCE pilot pressure turn the pilot adjust screw beneath the cover screw clockwise To INCREASE pilot pressure turn the pilot adjust screw counterclockwise Replace and tighten cover screw PRESSURE REGULATOR ADJUSTMENT The pressure regulator has been factory adjusted see control for s...

Страница 4: ...ionary information above If you don t smell gas go to next step 6 Remove the pilot access panel s located under the gas control unit 7 Find pilot follow small metal tubes from gas control 8 Turn knob on gas control counterclockwise to PILOT 9 Depress control knob all the way and hold in Imme diately light the pilot with a match Continue to hold the control knob down for about one 1 minute after th...

Отзывы: