Menu 1
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
36
Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
Keypad reference
If Keypad reference is selected the drive sequencer is controlled directly by the keypad keys and the keypad reference parameter (Pr
1.17
) is
selected. The sequencing bits, Pr
6.30
to Pr
6.34
, have no effect and jog is disabled.
Pr
1.15
defines how the value of Pr
1.50
is derived as follows:
*Pr
1.45
to Pr
1.47
can be controlled by digital inputs to define the value of Pr
1.50
as follows:
**The presets are selected automatically in turn. Pr
1.16
defines the time between each change.
Pr
1.49
and Pr
1.50
then define the reference as follows:
This parameter defines the time between preset reference changes when Pr
1.15
is set to 9. If Pr
1.48
is set to 1 then the preset counter and timer are
reset and preset 1 will be selected.
1.15
Preset selector
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
Open-loop, Closed-loop vector, Servo
0 to 9
Default
Open-loop, Closed-loop vector, Servo
0
Update rate
4ms read
Value of Pr 1.15
Pr 1.50
0
Selected by terminal input*
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
Selected by timer**
Pr 1.47
Pr 1.46
Pr 1.45
Pr 1.50
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1
4
1
0
0
5
1
0
1
6
1
1
0
7
1
1
1
8
Pr 1.49
Pr 1.50
Reference
1
1
Analog reference 1 (Pr
1.36
)
1
>1
Preset defined by Pr
1.50
(Pr
1.21
to Pr
1.28
)
2
1
Analog reference 2 (Pr
1.37
)
2
>1
Preset defined by Pr
1.50
(Pr
1.21
to Pr
1.28
)
3
x
Preset defined by Pr
1.50
(Pr
1.21
to Pr
1.28
)
4
x
Keypad reference (Pr
1.17
)
5
x
Precision reference (Pr
1.18
and Pr
1.19
)
1.16
Preset reference selector timer
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Range
Open-loop, Closed-loop vector, Servo
0 to 400.0 s
Default
Open-loop, Closed-loop vector, Servo
10.0
Update rate
Background read