190
Unidrive M702 User Guide
Issue Number: 3
11.10 Menu 10: Status and trips
Parameter
Range( )
Default( )
Type
OL
RFC-A / S
OL
RFC-A
RFC-S
10.001
Drive OK
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.002
Drive Active
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.003
Zero Speed
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.004
Running At Or Below Minimum Speed
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.005
Below Set Speed
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.006
At Speed
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.007
Above Set Speed
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.008
Rate Load Reached
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.009
Current Limit Active
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.010
Regenerating
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.011
Braking IGBT Active
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.012
Braking Resistor Alarm
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.013
Reverse Direction Commanded
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.014
Reverse Direction Running
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.015
Supply Loss
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.016
Under Voltage Active
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.017
Motor Overload Alarm
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.018
Drive Over-temperature Alarm
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.019
Drive Warning
Off (0) or On (1)
RO
Bit
ND
NC
PT
10.020
Trip 0
0 to 255
RO
Txt
ND
NC
PT
PS
10.021
Trip 1
0 to 255
RO
Txt
ND
NC
PT
PS
10.022
Trip 2
0 to 255
RO
Txt
ND
NC
PT
PS
10.023
Trip 3
0 to 255
RO
Txt
ND
NC
PT
PS
10.024
Trip 4
0 to 255
RO
Txt
ND
NC
PT
PS
10.025
Trip 5
0 to 255
RO
Txt
ND
NC
PT
PS
10.026
Trip 6
0 to 255
RO
Txt
ND
NC
PT
PS
10.027
Trip 7
0 to 255
RO
Txt
ND
NC
PT
PS
10.028
Trip 8
0 to 255
RO
Txt
ND
NC
PT
PS
10.029
Trip 9
0 to 255
RO
Txt
ND
NC
PT
PS
10.030
Braking Resistor Rated Power
0.000 to 99999.999 kW
RW
Num
US
10.031
Braking Resistor Thermal Time Constant
0.000 to 1500.000 s
See Table 11-5
RW
Num
US
10.032
External Trip
Off (0) or On (1)
Off (0)
RW
Bit
NC
10.033
Drive Reset
Off (0) or On (1)
Off (0)
RW
Bit
NC
10.034
Number Of Auto-reset Attempts
None (0), 1 (1), 2 (2), 3 (3), 4 (4), 5 (5), Infinite (6)
None (0)
RW
Txt
US
10.035
Auto-reset Delay
0.0 to 600.0 s
1.0 s
RW
Num
US
10.036
Auto-reset Hold Drive ok
Off (0) or On (1)
Off (0)
RW
Bit
US
10.037
Action On Trip Detection
00000 to 11111
00000
RW
Bin
US
10.038
User Trip
0 to 255
RW
Num
ND
NC
10.039
Braking Resistor Thermal Accumulator
0.0 to 100.0 %
RO
Num
ND
NC
PT
10.040
Status Word
000000000000000 to 111111111111111
RO
Bin
ND
NC
PT
10.041
Trip 0 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.042
Trip 0 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.043
Trip 1 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.044
Trip 1 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.045
Trip 2 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.046
Trip 2 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.047
Trip 3 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.048
Trip 3 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.049
Trip 4 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.050
Trip 4 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.051
Trip 5 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.052
Trip 5 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.053
Trip 6 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.054
Trip 6 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.055
Trip 7 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
10.056
Trip 7 Time
00:00:00 to 23:59:59
RO
Time
ND
NC
PT
PS
10.057
Trip 8 Date
00-00-00 to 31-12-99
RO
Date
ND
NC
PT
PS
Содержание Unidrive M702
Страница 283: ......
Страница 284: ...0478 0002 03 ...