Unidrive M400 User Guide
113
Issue Number: 2
Parameter
Range (
Ú
)
Default (
Ö
)
Type
OL
RFC-A
OL
RFC-A
04.001
Current Magnitude
±VM_DRIVE_CURRENT A
RO
Num ND NC PT FI
04.002
Torque Producing Current
±VM_DRIVE_CURRENT A
RO
Num ND NC PT FI
04.003
Final Torque Reference
±VM_TORQUE_CURRENT %
RO
Num ND NC PT FI
04.004
Final Current Reference
±VM_TORQUE_CURRENT %
RO
Num ND NC PT FI
04.005
Motoring Current Limit
±VM_MOTOR1_CURRENT_LIMIT %
165.0 %
175.0 % RW Num
RA
US
04.006
Regenerating Current Limit
±VM_MOTOR1_CURRENT_LIMIT %
165.0 %
175.0 % RW Num
RA
US
04.007
Symmetrical Current Limit
±VM_MOTOR1_CURRENT_LIMIT %
165.0 %
175.0 % RW Num
RA
US
04.008
Torque Reference
±VM_USER_CURRENT %
0.0 %
RW Num
US
04.011
Torque Mode Selector
0 to 5
0
RW Num
US
04.013
Current Controller Kp Gain
0.00 to 4000.00
20.00
RW Num
US
04.014
Current Controller Ki Gain
0.000 to 600.000
40.000
RW Num
US
04.015
Motor Thermal Time Constant 1
1 to 3000 s
179 s
RW Num
US
04.016
Thermal Protection Mode
00 to 11
00
RW
Bin
US
04.017
Magnetising Current
±VM_DRIVE_CURRENT A
RO
Num ND NC PT FI
04.018
Final Current Limit
±VM_TORQUE_CURRENT %
RO
Num ND NC PT
04.019
Motor Protection Accumulator
0.0 to 100.0 %
RO
Num ND NC PT PS
04.020
Percentage Load
±VM_USER_CURRENT %
RO
Num ND NC PT FI
04.022
Inertia Compensation Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
04.024
User Current Maximum Scaling
±VM_TORQUE_CURRENT_UNIPOLAR
%
165.0 %
175.0 % RW Num
RA
US
04.025
Low Frequency Thermal Protection
Mode
0 to 1
0
RW Num
US
04.026
Percentage Torque
±VM_USER_
CURRENT %
RO
Num ND NC PT FI
04.036
Motor Protection Accumulator
Power-up Value
Power down (0), Zero (1), Real time (2)
Power down (0)
RW
Txt
US
04.041
User Over Current Trip Level
0 to 100 %
100 %
RW Num
RA
US
RW
Read / Write
RO Read-only
Bit Bit parameter
Txt
Text string
Date Date parameter
Time Time parameter
Chr
Character
parameter
Bin Binary parameter
IP IP address
Mac MAC address
Ver
Version number
SMP
Slot, menu,
parameter
Num Number parameter
DE Destination
ND No default value
RA
Rating dependent
NC
Non-copyable
PT
Protected
FI
Filtered
US User save
PS
Power-down
save
Содержание Unidrive M400
Страница 197: ......
Страница 198: ...0478 0044 02 ...