background image

3

2

General

Your Emerson Ceiling Fan/Light Remote
Control consists of hand-held transmitter and
a receiver which is mounted under the fan
ceiling cover. The remote control is designed
to separately control your ceiling fan speed
and light intensity. There are four push
buttons   (

.

,

..

,

...

,

....

)  to set the fan speed

and turn the fan off. The light (    ) push
button turns the light on and off and controls
the light intensity. The red indicator light will
illuminate while any button is pressed,
indicating that the battery is good.

The remote control transmitter is powered by
two AAA alkaline batteries (not included).
To prevent possible damage if the batteries
should leak, be sure to remove the batteries
when the control is not to be used for an
extended period of time.

Code switches in the transmitter may be set
in 32 different positions. If your fan and light
go on and off without using your control, you
may be getting interference from other
remote units such as garage door openers,
car alarms or security systems. To remedy
this situations, simply change the
combination code in your transmitter.

Preset Memory Feature

Your Emerson receiver is equipped with a
preset memory feature. If the AC supply to
the receiver is powered through a wall switch,
when the switch is turned OFF, the control

will remember the light intensity and fan
speed. When the switch is turned back ON
the light and fan will resume operation as
they were prior to the switch being turned
OFF.

Installation of Battery

1.

Remove the battery cover by pressing
firmly below the arrow and sliding the
cover off the control (Figure 1).

2.

Install two AAA alkaline batteries.

Your remote control transmitter has code
switches which must be set in one of 32
possible code combinations. The five levers
(numbered 1, 2, 3, 4, and 5) on the switches
are factory-set in the ON (up) position. Do not
use this setting. Change the switch settings
as follows:

1.

Slide the five switch levers in the remote
control (transmitter) to your choice of ON
(up) or down positions. Use a ball-point
pen or small screwdriver and slide the
levers firmly up or down.

1.

After electricity has been turned off at main
fuse box or circuit breaker box, remove the
ceiling cover from the hanger bracket.

2.

Disconnect the supply wiring to the fan by
removing wire connectors. Do not
disconnect the green/bare ground wires.

3.

Connect the black supply wire to the
receiver black wire (AC IN L). Connect the
white supply wire to the receiver white wire
(AC IN N). Use only listed wire connectors
(supplied) to make connections.

To avoid possible electrical shock, be
sure electricity is turned off at the
main fuse or circuit breaker box
before installing the receiver.

CODE
SWITCHES

SR400 REMOTE 
CONTROL

BATTERY 
COMPARTMENT 
COVER

TWO AAA 
BATTERIES 

REMOTE CONTROL
LEVERS

ON

1

2

3

4 5

I

BARE

GREEN/GROUND

ANTENNA

WHITE

TO

AC SUPPLY

WHITE

BLACK

BLUE

WHITE

RED

BLUE

RECEIVER

FAN HOUSING

LIGHT

HANGER
BALL

CEILING
COVER

ANTENNA

HANGER
BRACKET

BLACK

WHITE

RED

BLUE

RECEIVER

Setting Operating Frequency

of Transmitter (Figure 1)

Installation of Receiver (Figure 2)

2.

When power is restored after installation of
the wall control, push and hold the fan OFF
button (    ) for 3 to 5 seconds to set the
code in the receiver.

3.

The sixth switch marked ON and I is for
dimming control of lights: Set switch to
ON to allow for dimming of the lights. Set
switch to I for no dimming of the lights
such as for fluorescent bulbs.

4.

Connect the receiver white wire (TO
MOTOR N) to the fan white wire. Connect
the receiver red wire (TO MOTOR L) to
the fan black wire. Connect the receiver
blue wire (FOR LIGHT) to the fan blue
wire.

CAUTION: If no light exist on your ceiling
fan, cap the blue wire on the receiver with
a wire connector.

5.

Push the connected wires up into the
junction box and position the receiver in
the hanger bracket above the hanger ball.
Lay the antenna wire on top of the
receiver.

6.

Reinstall the ceiling cover and restore
electrical power to the circuit.

Figure 1

Figure 2

WARNING

!

LIMITED WARRANTY

What The Warranty Covers:

All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the product to be
covered.

What The Period Of Coverage Is:

All components are covered by this warranty for one year from the date you purchased your remote control. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Company Do To Correct Problems:

Emerson Company will replace a defective Emerson Remote Control at no charge to you. We will ship the repaired product or replacement to you at no charge, but you are
responsible for all costs or removal, reinstallation and shipping of the product to Emerson.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE REMOTE CONTROL TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF
PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Company, 8100 W.

Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Remote Control should be properly
packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:

This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your remote control while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or
other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF
ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use.
Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

Содержание SR400

Страница 1: ...er Before installing or servicing the ceiling fan or receiver switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION 1 To avoid possible electrical shock b...

Страница 2: ...ansmitter may be set in 32 different positions If your fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter Preset Memory Feature Your Emerson receiver is equipped with a preset memory feature If the AC...

Страница 3: ...box before installing the receiver BARE GREEN GROUND ANTENNA WHITE TO AC SUPPLY WHITE BLACK BLUE WHITE RED BLUE RECEIVER FAN HOUSING LIGHT HANGER BALL CEILING COVER ANTENNA HANGER BRACKET BLACK WHITE RED BLUE RECEIVER Setting Operating Frequency of Transmitter Figure 1 Installation of Receiver Figure 2 2 When power is restored after installation of the wall control push and hold the fan OFF button...

Страница 4: ...at the battery is good power indicator light should light when any button is pressed Check that the receiver is wired properly Check that code switches in the remote control and receiver are set in the same position Short Range If the remote control operates the fan when close to it but does not operate it at a distance of 40 feet try placing the antenna wire outside of the ceiling cover Trouble S...

Страница 5: ...mote Control should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Company Use of parts or accessories not authorized by Emerson Company Mishandling improper installation modifications or damage to your...

Отзывы: