2

  

U.L. Model No.: 52-CL

Table of Contents

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

a. Use this unit only in a manner intended by the 

manufacturer.  If you have questions, contact the 

manufacturer.

b. Before servicing or cleaning unit, switch power 

off at service panel and lock service panel 

disconnecting means to prevent power from 

being switched on accidentally. When the service 

disconnecting means cannot be locked, securely 

fasten a warning device, such as a tag, to the 

service panel.

 

WARNING

!

To reduce the risk of electrical shock, this fan must be 

installed with an isolating wall control/switch.

This product is designed to use only those parts 

supplied with this product and/or any accessories 

designated specifically for use this product. 

Substitution of parts or accessories not designated 

for use with this product by Emerson could result in 

personal injury or property damage.

To reduce the risk of personal injury, do not bend 

the blade flange when installing the blade flanges, 

balancing the blades or cleaning the fan. Do not insert 

foreign objects in between rotating fan blades.

 

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned 

off at the fuse box before wiring, and do not operate 

fan without blades.

2. All wiring must be in accordance with the National 

Electrical Code “ANSI/NFPA 70-2017” and Local 

Electrical Codes. Use the National Electrical Code 

if Local Codes do not exist. The ceiling fan must be 

grounded as a precaution against possible electrical 

shock. Electrical installation should be made or 

approved by a licensed electrician.

3.  The outlet box and joist must be securely mounted 

and capable of reliably supporting at least 50 pounds. 

Use only U.L. outlet boxes listed as “Acceptable for 

Fan Support of 22.7kg. (50 lbs.) or less”, and use the 

mounting screws provided with the outlet box. Most 

outlet boxes commonly used for support of light fixtures 

are not acceptable for fan support and may need to be 

replaced. Consult a qualified electrician if in doubt.

4. The downrod furnished with the fan provides the 

minimum recommended floor to fan blade clearance 

for an 8 foot ceiling.

5. Follow the recommended instructions for the proper 

method of wiring your ceiling fan. If you do not know 

enough about electrical wiring, have your fan installed 

by a licensed electrician.

NOTE: This fan is suitable for use with solid-state speed 

controls.

1. Read your owner’s manual carefully and keep it for 

future reference.

2. Be careful of the fan and blades when cleaning, 

painting, or working near the fan. Always turn off the 

power to the ceiling fan before servicing.

3.  Do not put anything into the fan blades while they are 

turning.

4. Do not operate reverse switch until fan blades have 

come to a complete stop.

READ AND SAVE THESE INSTRUCTIONS

Section Page
Safety Instructions   . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1. Unpacking Instructions   . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements  . . . . . . . . . . . . . . . . . . . . .  4
3. How to Hang Your Ceiling Fan  . . . . . . . . . . . . . . . . 5
4. How to Wire Your Ceiling Fan    . . . . . . . . . . . . . . . . 6
5. Ceiling Fan Assembly  . . . . . . . . . . . . . . . . . . . . . . . 7

Section Page
6. Using Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . 8
7. Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8. Accessories    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9. Troubleshooting   . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10. Repair Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ceiling Fan Limited Warranty   . . . . . . . . . . . . . . . . . . 11

To reduce the risk of injury, install the fan so that the 

blades are at least 7 ft. (2.1m) above the floor.

 

CAUTION

!

Содержание SNUGGER CF804SBS02

Страница 1: ...3 9 Lbs Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com TRADITIONAL CF805SBS02 Brushed Steel CF805SORB02 Oil Rubbed Bronze CF805SWW02 Appliance White 42 Model Numbers Net Weight 11 2 Lbs CF804SBS02 Brushed Steel CF804SORB02 Oil Rubbed Bronze CF804SWW02 Appliance White ...

Страница 2: ...recaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7kg 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly u...

Страница 3: ...OTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding 2 6 3 4 5 7 8 1 HARDWARE CONTENTS Part Description Quantity 1 Wire Connectors 12 ga 3 2 M5 x 6mm Phillips Washer Head Screws 16 3 M5 x 10mm Phillips Pan Head Screws with Internal Tooth Washers 5 4 1 4 Hex Locknuts 4 5 W...

Страница 4: ... Circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is no...

Страница 5: ...ified electrician if in doubt WARNING To reduce the risk of injury install the fan so that the blades are at least 7 ft 2 1m above the floor Figure 1 CAUTION MOUNTING PLATE LEVELING WASHERS if required OUTLET BOX MOUNTING SCREWS 2 supplied with outlet box Figure 2 3 1 Securely attach the Mounting Plate to the Outlet Box Figure 2 using Two Screws supplied with outlet box NOTE For better fan perform...

Страница 6: ...igure 4 To avoid risk of fire or shock check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 4 2 Connect the Fan Motor White Wire to the Supply White neutral Wire using a supplied Wire Connector Figure 5 WIRE CONNECTOR FAN ...

Страница 7: ...pinch wires between the motor bracket and mounting plate WARNING M5 x 10mm PHILLIPS PAN HEAD SCREWS WITH INTERNAL WASHERS 4 FAN HOUSING HOLES 4 5 2 Align the Four Holes in the Fan Housing with the Holes in the Mounting Plate and install Four M5 x 10mm Phillips Pan Head Screws with Internal Tooth Washers supplied Figure 8 M5 x 6mm PHILLIPS WASHER HEAD SCREWS 3 per blade BLADES 5 FLANGES 5 CAPTIVE S...

Страница 8: ...r Counter Clockwise Winter Clockwise 6 1 Restore Electrical Power to the Outlet Box by turning the Electricity on at the Main Fuse Box Connect the Wood Pendant with Chain to the 3 Speed Switch Pull Chain using the Chain Coupling Figure 11 Check the operation of the Fan by gently pulling on the 3 Speed Switch Pull Chain Figure 11 The operation sequence is as follows 1st pull High 2nd pull Medium 3r...

Страница 9: ...ake sure all screws in motor housing are snug not over tight 3 Screws securing fan blade flanges 3 Check to make sure the screws which attach the fan to motor are loose blade flanges to the motor are tight 4 Wire connectors inside switch housing 4 Check to make sure wire connectors in switch housing rattling are not rattling against each other or against the interior wall of the switch housing 5 S...

Страница 10: ...nge Sets set of 5 762573 3 762573 6 762573 3 Blade Sets set of 5 765172 DC MH 765172 DC MO 765172 WW BO 4 Loose Parts Bag Containing 762567 3 762567 1 762567 2 Blade Hardware Hanging Hardware Pull Chain Ball 5 Harness Wiring 762569 3 762569 2 762569 4 Owner s Manual BP7192 10 BP7192 10 BP7192 10 42 Part Numbers Key Model Number Model Number Model Number No Description CF804SBS02 CF804SORB02 CF804S...

Страница 11: ...normal wear and tear rather than due to defects in materials or workmanship Loss or damage resulting from conditions beyond our reasonable control including without limitation unforeseeable operating environmental conditions repairs not made at Our factory or authorized service center use of parts or accessories not provided to You as part of this warranty by Our factory or authorized service cent...

Страница 12: ...can be found on the nameplate on top of the fan housing The date code can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above and keep it in a safe place for future use Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday DIVISION OF LUMINANCE BRANDS 1945 S Tubeway A...

Отзывы: