Functional Description
RTM-ATCA-F125 Installation and Use (6806800K30C
)
48
The management power is used to directly power the devices connected to the front-blade I2C
bus, namely for serial EEPROM, temperature sensors and I/O extender device.
+12 V payload power is the source for the onboard DC to DC converters needed for the RTM
payload.
4.8.1
Power-good Indication
The RTM FPGA includes logic to generate an overall power-good signal to the front-blade based
on the state of the various power supplies. Since this signal comes from the FPGA, it also serves
as an indication that the FPGA configuration has completed.
4.8.2
Power Requirements
The table below summarizes the power requirements of the RTM-ATCA-F125.
Table 4-9 Power Requirements
Voltage
Maximum Current
+3.3V Management
0.2 A
+12 V Payload
1.8 A
Содержание RTM-ATCA-F125
Страница 6: ...RTM ATCA F125 Installation and Use 6806800K30C Contents 6 Contents Contents ...
Страница 8: ...RTM ATCA F125 Installation and Use 6806800K30C 8 List of Tables ...
Страница 10: ...RTM ATCA F125 Installation and Use 6806800K30C 10 List of Figures ...
Страница 14: ...RTM ATCA F125 Installation and Use 6806800K30C About this Manual 14 About this Manual ...
Страница 28: ...Hardware Preparation and Installation RTM ATCA F125 Installation and Use 6806800K30C 30 ...
Страница 30: ...Controls LEDs and Connectors RTM ATCA F125 Installation and Use 6806800K30C 32 Figure 3 1 Face Plate ...
Страница 32: ...Controls LEDs and Connectors RTM ATCA F125 Installation and Use 6806800K30C 34 ...
Страница 48: ...Related Documentation RTM ATCA F125 Installation and Use 6806800K30C 50 ...
Страница 58: ...RTM ATCA F125 Installation and Use 6806800K30C Sicherheitshinweise 60 ...
Страница 60: ...Index RTM ATCA F125 Installation and Use 6806800K30C 62 ...
Страница 61: ......