WARNING
Risk to Personnel and Equipment: If primary pack and probe packing are not
replaced with every retrieval operation, they can open, result in a spill of corrosive
gas or liquid, and result in serious injury. Both primary packing and probe packing
should be replaced every retrieval operation. Never reuse either primary packing
or probe packing.
2. Inspect the threads on the mechanical plug and mount it on the plug pilot by
screwing it onto the plug hexagon until it seats at the plug pilot o-ring. Lubricate
the plug threads properly.
NOTICE
If the devices requires a specific orientation, make sure the orientation is correctly
marked on the top of the plug.
3. If applicable, expand the retriever and fit the safety clamp.
4. Install the expanded retriever on the service valve. Tighten the hammer nut
properly by using either a brass or a plastic hammer.
5. Verify that the retriever bleed valve and the service bleed valve are closed.
6. Slowly open the by-pass valves on the service valve to pressurize the retriever.
When the pressure is equalized, open both balls on the service valve.
7. If installed, remove the safety clamp and in a rotating-sliding movement, collapse
the retriever all the way until the plug stops at the access fitting.
NOTICE
Be careful when entering the plug onto the access fitting so that the threads are not
damaged.
8. Tighten the plug for approximately 15 turns until it seats in the access fitting. Then
tighten the plug properly so it is secure.
9. Bleed off the pressure in the retriever by opening the bleed valve. You can use a
diversion hose to divert the media being bled off.
10. Ensure that all pressure is released from the tool. Keep the bleed valve open.
DANGER
Danger to Personnel and Equipment: If the pilot body is not fully disconnected
from the plug hexagon, gasses or liquids will escape, causing serious injury. Make
sure that the pilot body is fully disconnected from the plug hexagon before
unscrewing the tool.
11. Unscrew the pilot plug from the plug and expand the tool. If applicable, mount the
safety clamp.
12. Remove both the retriever and the service valve.
13. If applicable, check orientation marks and use a wrench to rotate the plug clockwise
to align it.
Operating instructions
User Manual
June 2020
ROX000295904
30
www.Emerson.com/Roxar
Содержание Roxar
Страница 1: ...User Manual ROX000295904 Rev AC June 2020 Roxar Mechanical Retrieval Tool User Manual ...
Страница 2: ...2 ...
Страница 4: ...Contents User Manual June 2020 ROX000295904 4 www Emerson com Roxar ...
Страница 20: ...Technical description User Manual June 2020 ROX000295904 20 www Emerson com Roxar ...
Страница 34: ...Operating instructions User Manual June 2020 ROX000295904 34 www Emerson com Roxar ...
Страница 44: ...Double ball service valve assembly Attachments User Manual June 2020 ROX000295904 44 www Emerson com Roxar ...
Страница 45: ...User Manual Attachments ROX000295904 June 2020 www Emerson com Roxar 45 ...