85
Rosemount 8600 Vortex Flow Meter
Reference Manual
May 2019
Troubleshooting
00809-0100-4860, Rev BF
8.
Align the housing adapter with the housing base and attach with the two housing
adapter screws.
9.
Tighten the conduit adapter to the housing adapter.
5.6.7
Changing the housing orientation
The entire electronics housing may be rotated in 90 degree increments for easy viewing.
Use the following steps to change the housing orientation:
1.
Loosen the screw on the access cover on the bracket (if present) and remove the
cover.
2.
Loosen the three housing rotation set screws at the base of the electronics housing
with a
5
/
32
-in. (4 mm) hex wrench by turning the screws clockwise (inward) until
they clear the bracket.
3.
Slowly pull the electronics housing out of the bracket.
4.
Unscrew the sensor cable from the housing with a
5
/
16
-in. open end wrench.
Note
Do not pull the housing more than 1.5-in. (40 mm) from the top of the bracket until the
sensor cable is disconnected. Damage to the sensor may occur if this sensor cable is
stressed.
5.
Rotate the housing to the desired orientation.
6.
Hold it in this orientation while you screw the sensor cable onto the base of the
housing.
Note
Do not rotate the housing while the sensor cable is attached to the base of the housing. This
will stress the cable and may damage the sensor.
7.
Place the electronics housing into the top of the bracket.
8.
Use a hex wrench to turn the four housing rotation screws counterclockwise to
engage the bracket.
5.6.8
Temperature sensor replacement (MTA option only)
Replacement of the temperature sensor should only be necessary in the event of a failure.
Use the following procedure for replacement.
Note
Disconnect power before replacing temperature sensor.
1.
Turn off power to Rosemount 8600D.
2.
Remove temperature sensor from meter body by using a
1
/
2
-in. open end wrench.
to remove the bracket.
Содержание Rosemount 8600 Series
Страница 1: ...Reference Manual 00809 0100 4860 Rev BF May 2019 Rosemount 8600 Series Vortex Flow Meter ...
Страница 2: ......
Страница 8: ...viii Reference Manual 00809 0100 4860 Rev BF Title Page May 2019 Title Page ...
Страница 10: ...Reference Manual 00809 0100 4860 Rev BF Introduction May 2019 2 Rosemount 8600 Vortex Flow Meter ...
Страница 110: ...Reference Manual 00809 0100 4860 Rev BF Specifications and Reference Data May 2019 102 Rosemount 8600 Vortex Flow Meter ...
Страница 112: ...Reference Manual 00809 0100 4860 Rev BF Product Certifications May 2019 104 Rosemount 8600 Vortex Flow Meter ...
Страница 129: ......