To reset the total of the Rosemount 705 Transmitter via Modbus, follow the steps below.
1. Navigate to
Modbus
connection.
2. Map
705.Accumulaor_Reset
.
3.
Submit
.
To reset the total of the Rosemount 705 Transmitter via OPC, follow the steps below.
1. Navigate to
OPC
connection.
2. Map
705.Accumulaor_Reset
.
3.
Submit
.
To reset the total of the Rosemount 705 Transmitter via EtherNet/IP, follow the steps below.
1. Navigate to
EtherNet/IP
connection.
2. Map
705.Accumulaor_Reset
.
3.
Submit
.
5.6
Reset/restore device
The Rosemount 705 Transmitter can be reset remotely over the wireless network, or locally via the wired
maintenance port. Resetting the device will cause the device to temporarily drop offline and rejoin to the
configured wireless network. When resetting the device, you can choose to reset the device with the
same configuration as it already has, or to revert the configuration settings to the original values that
were present when the device left the manufacturer. When reverting the configuration settings to
original values, not the turbine meter K-factor will also be reverted, so the turbine meter should be
verified to ensure the correct K-factor is being used.
5.7
Suspend (pause) the totalization in the device
The Rosemount 705 Transmitter allows the totalization to be stopped, which will hold the current
totalized volume value and ignore any new input pulses. This can be done through a host connection to
the wireless gateway.
5.8
Average flow rate filtering period
The average flow rate filtering period controls how heavily the average flow rate is filtered. The default
setting of one second will cause the Rosemount 705 Transmitter to report the average flow rate over a
time interval of one second. Setting the period to a larger value will reduce noisy flow rate
measurements, but will increase the time constant of the reported value.
Fast Keys
3, 5, 2
Fast Keys
2, 2, 2, 2, 3
Содержание Rosemount 705
Страница 1: ...Reference Manual 00809 0200 4705 Rev AB May 2017 Rosemount 705 Wireless Totalizing Transmitter ...
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0200 4705 Rev AB Contents May 2017 Contents ...
Страница 10: ...2 Reference Manual 00809 0200 4705 Rev AB Introduction May 2017 Introduction ...
Страница 32: ...28 Reference Manual 00809 0200 4705 Rev AB Commissioning May 2017 Commissioning ...
Страница 46: ...42 Reference Manual 00809 0100 4248 Rev CA Operation and Maintenance May 2017 Operation and Maintenance ...
Страница 57: ...53 Product Certifications Product Certifications May 2017 Reference Manual 00809 0200 4705 Rev AB ...
Страница 58: ...Product Certifications May 2017 Reference Manual 00809 0200 4705 Rev AB 54 Product Certifications ...
Страница 69: ......