Reference Manual

00809-0200-4705, Rev AB

May 2017

Rosemount

 705 Wireless Totalizing 

Transmitter

Содержание Rosemount 705

Страница 1: ...Reference Manual 00809 0200 4705 Rev AB May 2017 Rosemount 705 Wireless Totalizing Transmitter ...

Страница 2: ......

Страница 3: ...mount configuration 12 3 2 2 Installing the transmitter in a remote mount configuration 14 3 3 Wireless considerations 15 3 3 1 Selected an installation location and position 16 3 3 2 Electrical 17 3 3 3 Verifying operating atmosphere 17 3 4 Remote antenna optional 18 3 4 1 WN remote antenna option 18 3 5 LCD display 19 3 6 Grounding the transmitter 19 4Section 4 Commissioning 4 1 Safety messages ...

Страница 4: ... device 39 5 7 Suspend pause the totalization in the device 39 5 8 Average flow rate filtering period 39 5 9 Low Flow cut off 40 5 10 Input sensitivity 40 5 11 How to reset the totalized volume 40 5 12 Service support 40 AAppendix A Specifications and Reference Data A 1 Specifications 43 A 1 1 Functional specifications 43 A 1 2 Physical specifications 43 A 1 3 Frequency input specifications 44 A 1...

Страница 5: ...al specifications 56 C 2 6 RF lightning arrestor 56 C 2 7 Ratings 56 C 2 8 Vibration 56 C 3 Installation considerations 57 C 3 1 Antenna mounting 57 C 3 2 Antenna height 57 C 3 3 Coaxial cable 57 C 3 4 Installing coaxial drip loop 57 C 3 5 Applying coaxial sealant moisture protection 57 C 4 Transient lightning considerations 57 C 4 1 Gateway transient protection 57 C 4 2 RF lightning arrestor grou...

Страница 6: ...vi Reference Manual 00809 0200 4705 Rev AB Contents May 2017 Contents ...

Страница 7: ...24 hours a day Equipment service needs International 1 952 906 8888 The Rosemount 705 Transmitter and all other wireless devices should be installed only after the Smart Wireless Gateway has been installed and is functioning properly Wireless devices should also be powered up in order of proximity from the Gateway beginning with the closest This will result in a simpler and faster network installa...

Страница 8: ...power module contains two C size primary lithium batteries Primary lithium batteries are regulated in transportation by the U S Department of Transportation and are also covered by IATA International Air Transport Association ICAO International Civil Aviation Organization and ARD European Ground Transportation of Dangerous Goods It is the responsibility of the shipper to ensure compliance with the...

Страница 9: ...s techniques for properly commissioning the device Section 5 Operation and Maintenance contains operation and maintenance techniques Appendix A Specifications and Reference Data supplies reference and specification data as well as ordering information Appendix B Product Certifications contains approval information Appendix C High Gain Remote Antenna Option contains specification data and installat...

Страница 10: ...2 Reference Manual 00809 0200 4705 Rev AB Introduction May 2017 Introduction ...

Страница 11: ... to the pulse terminals on the transmitter To ensure a proper turbine meter connection anchor the turbine meter lead wires into the appropriate compression terminals and tighten the screws In noisy environments be sure to properly ground the transmitter using the ground terminal Failure to follow these installation guidelines could result in death or serious injury Only qualified personnel should ...

Страница 12: ...bine meter leads according to the diagram Figure 2 1 on page 8 Note For noisy electrical environments it is best practice to ground the loop accordingly 3 Connect the black power module 4 Verify the connection and power by viewing the LCD display and seeing the power up sequence 5 Replace the cover and tighten Figure 2 1 Rosemount 705 Transmitter Terminal Block A Pulse input connection B HART term...

Страница 13: ...To check or change sensor configuration using a Field Communicator enter the following Fast Key sequence 2 1 2 2 4 Supported engineering unit codes The following engineering units are supported by the Rosemount 705 Transmitter Total volume Volumetric flow rate US gallons US gallons per second US gallons per minute US gallons per hour US gallons per day Liters Liters per second Liters per minute Li...

Страница 14: ...etwork If the Network ID and Join Key are not identical the transmitter will not communicate with the network The Network ID and Join Key may be obtained from the Gateway on the Network Settings page on the web server or by clicking network information in the upper right hand corner Using a Field Communicator the Network ID and Join Key can be configured using a Field Communicator with the Fast Ke...

Страница 15: ...Only qualified personnel should perform the installation Explosions could result in death or serious injury Before connecting a Field Communicator in an explosive atmosphere make sure the instruments are installed in accordance with intrinsically safe or non incendive field wiring practices Verify the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations ce...

Страница 16: ...ted to the transmitter via conduit For installation instructions see Installing the transmitter in a remote mount configuration on page 14 3 2 1 Installing the transmitter in a direct mount configuration Figure 3 1 Direct Mount A Turbine meter B Rosemount 705 Transmitter C 1 in NPT connection to flow meter and two piece pipe union Note Direct mount installation should not be employed when using tu...

Страница 17: ...ready be applied to threads on the D1 direct mount option Note Wireless devices should only be powered up after the Smart Wireless Gateway in order of proximity from the Smart Wireless Gateway beginning with the closest device This results in a simpler and faster network installation 7 Connect the black power module Figure 3 3 Power Module Installation 8 Close the housing cover and tighten to safe...

Страница 18: ... of the connections 2 Pull the cable connection wiring through the supplied cable gland adapter for the turbine meter Then pull the cable wiring through the transmitter cable gland Note Pay attention to the orientation of the cable gland to ensure proper connection to transmitter 3 Attach the turbine meter or pulse output device wiring to the terminals as shown in the wiring diagrams beginning on ...

Страница 19: ...dule SmartPower Solutions model number 701PBKKF into the Rosemount 705 Transmitter to power the device Wireless devices should also be powered up in order of proximity from the Gateway beginning with the closest This will result in a simpler and faster network installation Enable Active Advertising on the Gateway to ensure that new devices join the network faster For more information see the Smart...

Страница 20: ...Rosemount 705 Transmitter Figure 3 8 Field Communicator Connections 3 3 1 Selected an installation location and position When choosing an installation location and position take into account access to the transmitter For best performance the antenna should be vertical with space between objects in a parallel metal plane such as a pipe or metal framework as the pipes or framework may adversely affe...

Страница 21: ...gh the cable entry in the side of the connection head Be sure to provide adequate clearance for cover removal and lead attachments remote option 3 3 3 Verifying operating atmosphere Verify the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Isolating the transmitter from sources of heat The transmitter will operate within specifications...

Страница 22: ...oser than 1 ft 0 3 m from the lightning arrestor 5 Use the coaxial sealant to seal each connection between the wireless field device lightning arrestor cable and antenna 6 Ensure the mounting mast and lightning arrestor are grounded according to local national electrical code Note Any spare lengths of coaxial cable should be placed in 12 in 0 3 m coils When installing remote mount antennas for the...

Страница 23: ...sition and snap into place Note the following LCD display temperature limits Operating 4 to 175 F 20 to 80 C Storage 40 to 185 F 40 to 85 C 3 Replace the transmitter cover Note Only use Rosemount Wireless LCD display part number 00753 9004 0002 The transmitted data may not match data displayed on LCD display due to differences in update rate and screen refresh rate Figure 3 9 Optional LCD Display ...

Страница 24: ...ents Use the options recommended by the facility for the specific turbine meter or pulse output device 1 Connect turbine meter wiring shield to the grounded transmitter housing 2 Ensure the transmitter housing is electrically isolated from the turbine meter or pulse output device wiring A Turbine meter B Transmitter ground point C Rosemount 705 Transmitter A C B ...

Страница 25: ...uld be powered up in order of proximity from the Gateway beginning with the device closest to the Gateway This will result in a simpler and faster network installation Failure to follow these installation guidelines could result in death or serious injury Only qualified personnel should perform the installation Explosions could result in death or serious injury Before connecting a Field Communicat...

Страница 26: ...equivalent of connecting wires from a transmitter to the Host System Using a Field Communicator or AMS Device Manager enter the Network ID and Join Key so they match the Network ID and Join Key of the gateway and other devices in the network If the Network ID and Join Key are not identical the Rosemount 705 Transmitter will not communicate with the network The Network ID and Join Key may be obtain...

Страница 27: ...y be adversely affected Any time the attached turbine meter is replaced the K factor setting should be verified and or modified accordingly to maintain a proper match If the K factor is not specified to be pre configured when ordering the Rosemount 705 Transmitter it will be shipped without any K factor configured In this case the K factor must be configured before any valid values can be obtained...

Страница 28: ... 1 Basic Setup 2 Configure Totalizing Option 3 Join Device to N W 4 Configure Update Rate 5 Configure Device Display 6 Configure Process Alerts 1 Long Tag 2 Tag 3 Model 4 Transmitter S N 5 Date 6 Description 7 Message 8 Model Numbers 9 Device Image 1 Universal 2 Field Device 3 Software 4 Hardware 5 DD Revision 1 MAC Address 2 Manufacturer 3 Device Tyoe 4 Device Revision 5 Software Revision 6 Hardw...

Страница 29: ...isplays the configured values at the update rate or can optionally be enabled for continuous display See Enabling the LCD continuous operation feature Diagnostic button display sequence More detailed diagnostic information can be obtained by removing the display cover of the Rosemount 705 Transmitter and momentarily depressing the DIAG button The LCD will display the diagnostic screens as shown in...

Страница 30: ...er of devices being joined and the number of devices in the current network For one device joining an existing network with multiple devices it may take up to five minutes It may take up to 60 minutes for multiple new devices to join the existing network 4 6 1 AMS Device Manager When the device has joined the network it will appear in the AMS Device Manager as illustrated below Searching for netwo...

Страница 31: ...Advertising has been enabled on the Gateway The Network ID and Join Key in the device must match the Network ID and Join Key of the Gateway The Network ID and Join Key may be obtained from the Gateway in the upper right hand corner labeled network information The Network ID and Join Key may be changed in the wireless device by using the following Fast Key sequence Function Fast Key sequence Menu i...

Страница 32: ...28 Reference Manual 00809 0200 4705 Rev AB Commissioning May 2017 Commissioning ...

Страница 33: ...itter up to a configurable rollover point Once the totalized volume reaches the rollover point the totalized value will automatically continue totalizing the volume starting from zero The rollover point defaults to 100 million but can be configured to any value between one and two billion Note the resolution of the totalized volume is reduced as the value gets larger Refer to the table below or se...

Страница 34: ...eld device 2 Fast keys 2 1 5 Configure Manual Setup Display Display Mode 5 2 Determining device health In addition system considerations must be observed to ensure the device is still connected to the wireless network and reporting values On an Emerson Smart Wireless Gateway this can be done by referring to the parameter PV_HEALTHY The PV_HEALTHY has a True state when the device is on the network ...

Страница 35: ...e Device Type Device information Tag user entered tag which is eight characters long will not display if all characters are blank Totalized volume screen accumulated total volume over time Average rate screen average rate value Electronics screen feature board temperature value can be modified to a specific variable in the DD A b c d e f g h ...

Страница 36: ...reading at the power module terminals can be modified to a specific variable in the DD Alert screen at least one alert is present this screen will not display if no alerts are present Device information Tag User entered tag which is 8 characters long will not display if all characters are blank Device identification Used to determine Device ID Software revision Indication of the software revision ...

Страница 37: ... the device has the correct join key this ID tells the user what network the device can connect with Network connection status The device has joined a network and has been fully configured and has multiple parents Supply voltage Voltage reading at the power module terminals Diagnostic button screen 4 1 The device is attempting to start the radio Diagnostic button screen 4 2 The device has just res...

Страница 38: ...in a disconnected state and requires a Force Join command to join the network Diagnostic button screen 4 5 The device is searching for the Network Diagnostic button screen 4 6 The device is attempting to join a network Diagnostic button screen 4 7 The device is connected to the Network but is in a Quarantined state n e t w k i d l e n e t w k D I S C N T N E T w K S R C H N G n e t w k N E G O T n...

Страница 39: ...periodic data Diagnostic button screen 4 9 the device has joined a network and has been fully configured and has multiple parents Diagnostic button screen 6 1 There is a critical error which may prevent the electronics board from operating correctly Diagnostic button screen 6 2 There is a warning which should be addressed but should not affect the device output Diagnostic button screen 7 1 Termina...

Страница 40: ...shing HART data Diagnostic button screen 9 Configuration of the transmitter is invalid such that critical operation of the device may be affected check the extended configuration status to identify which configuration item s need to be corrected Diagnostic button screen 10 Switch attached to the transmitter has failed and valid readings from that switch are no longer possible check the switch and ...

Страница 41: ...ropped from heights in excess of 20 ft Battery hazards remain when cells are discharged Environmental considerations As with any battery local environmental rules and regulations should be consulted for proper management of spent batteries If no specific requirements exist recycling through a qualified recycler is encouraged Consult the materials safety data sheet for battery specific information ...

Страница 42: ...umulator state totalized_volume average_flow variables and parameter can be mapped This is important to understand how to reset the totalized volume of the device via Modbus OPC or EtherNet IP Figure 5 1 Smart Wireless Gateway Modbus Register Map Table 5 1 Parameters for Modbus EtherNet IP and OPC Mapping Parameter name Description Read Write SUPPLY_VOLTAGE Maps the supply voltage of the device Fo...

Страница 43: ...e device with the same configuration as it already has or to revert the configuration settings to the original values that were present when the device left the manufacturer When reverting the configuration settings to original values not the turbine meter K factor will also be reverted so the turbine meter should be verified to ensure the correct K factor is being used 5 7 Suspend pause the total...

Страница 44: ... the turbine meter is not rotating If the Reduced setting is selected care should be taken to verify the device is properly reporting flow particularly at low frequencies 5 11 How to reset the totalized volume The totalized volume can be reset via the wireless network through the wireless gateway using a button located behind the electronics LCD display side housing cover or by connecting to the l...

Страница 45: ...sary to return goods that were exposed tohazardous substances Individuals who handle products exposed to a hazardous substance can avoid injury if they are informed of and understand the hazard If the product being returned was exposed to a hazardous substance as defined by OSHA a copy of the required Material Safety Data Sheet MSDS for each hazardous substance identified must be included with the...

Страница 46: ...42 Reference Manual 00809 0100 4248 Rev CA Operation and Maintenance May 2017 Operation and Maintenance ...

Страница 47: ...power module Replaceable Intrinsically Safe Lithium Thionyl Chloride power module with PBT polymer enclosure Ten year life at one minute update rate 1 Note Continuous exposure to ambient temperature limits 40 F or 185 F 40 C or 85 C may reduce specified power module life by less than 20 percent Field Communicator connections Communication terminals Terminal tabs are permanently fixed to terminal b...

Страница 48: ... field or pipeline with high vibration level 10 60 Hz 0 21mm displacement peak amplitude 60 2000 Hz 3g Wireless output unaffected when tested per the requirements of IEC60770 1 field with general application or pipeline with low vibration level 10 60 Hz 0 15 mm displacement peak amplitude 60 500 Hz 2 g Temperature limits 1 During surge event device may exceed maximum EMC deviation limit or reset h...

Страница 49: ...n with 2 4 GHz WirelessHART extended range antenna Shown with optional digital display and 2 4 GHz WirelessHART Antenna Shown without optional digital display A 2 4 GHz WirelessHART extended range antenna B 1 in NPT connection to flow meter C Ground screw assembly D Possible antenna rotation E Digital display cover F Transmitter electronics 1 50 38 A D B C 2 49 63 4 20 107 7 81 198 11 16 284 E 7 8...

Страница 50: ...nd Reference Data Figure A 2 Rosemount 705 Transmitter Mounting Configurations with Optional Pipe Mounting Bracket A 2 in U bolt for pipe mounting B Ground screw assembly C 1 in NPT connection to flow meter D Turbine meter connection Dimensions are in inches millimeters D 1 03 26 4 03 102 C 1 38 35 B A ...

Страница 51: ...ions NA No Hazardous Location Approval I5 U S A Intrinsically Safe I6 Canada Intrinsically Safe N5 U S A Division 2 Non incendive N6 Canada Division 2 Non incendive I1 ATEX Intrinsic Safety IU ATEX Intrinsic Safety for Zone 2 I7 IECEx Intrinsic Safety IY IECEx Intrinsic Safety for Zone 2 Wireless options Wireless update rate operating frequency and protocol WA3 User configurable update rate 2 4 GH...

Страница 52: ...ped separately order model 701PBKKF or part number 00753 9220 000 2 Limited availability consult factory for details Spare parts and accessories Spare parts and accessories 00705 9000 0001 Cable assembly 1 ft long for direct mount option 00705 9000 0002 Cable Assembly 10 ft long for remote mount option 03151 9270 0003 Remote housing bracket kit 701PBKKF Black power module Table A 1 Rosemount 705 W...

Страница 53: ...ived including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons B 4 Ordinary Location Certification from CSA The transmitter has been examined and tested to determine that the design meets the basic electrical mechanical and fire protection requirements by CSA a nationally recognized test laborat...

Страница 54: ...ild up it must not be rubbed or cleaned with solvents or a dry cloth 2 The Rosemount 705 Transmitter enclosure may be made of aluminum alloy and given a protective polyurethane paint finish however care should be taken to protect it from impact or abrasion if located in a Zone 0 area IU ATEX Intrinsic Safety for Zone 2 Certificate Baseefa14ATEX0375X Standards EN 60079 0 2012 EN 60079 11 2012 Marki...

Страница 55: ...nt finish however care should be taken to protect it from impact or abrasion if located in a Zone 0 area B 10 Brazil I2 INMETRO Intrinsic Safety Certificate UL BR 17 0019X Standards ABNT NBR IEC 60079 0 2008 Errata 1 2011 ABNT NBR IEC 60079 11 2009 Markings Ex ia IIC T4 Ga T4 60 C Ta 70 C See the table at the end of this section for entity parameters Special Condition for Safe Use X 1 See certific...

Страница 56: ...Product Certifications May 2017 Reference Manual 00809 0200 4705 Rev AB 52 Product Certifications B 12 Installation drawings Figure B 1 Rosemount 705 Wireless Totalizing Transmitter ...

Страница 57: ...53 Product Certifications Product Certifications May 2017 Reference Manual 00809 0200 4705 Rev AB ...

Страница 58: ...Product Certifications May 2017 Reference Manual 00809 0200 4705 Rev AB 54 Product Certifications ...

Страница 59: ... for the wireless field device always use established safety procedures to avoid falling or contact with high power electrical lines Install remote antenna components for the wireless field device in compliance with local and national electrical codes and use best practices for lightning protection Before installing consult with the local area electrical inspector electrical officer and work area ...

Страница 60: ...ns C 2 3 Coaxial material Heavy duty low loss LMR400 cable Minimum coaxial bend diameter 1 0 ft 0 3 m C 2 4 Antenna Remote mount omni directional antenna Fiberglass and aluminum construction 8 Db Gain WJ1 6dBi Meets MIL STD 810G Method 510 5 Procedure I and II C 2 5 Physical specifications Weight 1 0 lb 0 4 kg C 2 6 RF lightning arrestor In line lightning arrestor Electrical connection Lightning a...

Страница 61: ...fix the drip loop to the lower portion of the mast ensuring condensation or rainwater will flow away from the coaxial connections Figure C 1 Drip Loop Location A Coaxial drip loop C 3 5 Applying coaxial sealant moisture protection Utilize the coaxial sealant that is included in the high gain remote mounting kit package Follow included instructions for application on the coaxial connection C 4 Tran...

Страница 62: ...9 0200 4705 Rev AB 58 High Gain Remote Antenna Option C 5 Dimensional drawings Figure C 2 Device Connection and RF Lightning Arrestor A Antenna B Min drip loop 12 in 0 3 m C 25 ft 7 6 m Cable D Lightning arrestor E Mounting bracket n n n 53 2 75 4 PLS X A B C E D ...

Страница 63: ...Installing the high gain remote antenna 1 Mount the transmitter following best practice mounting procedures as outlined in the Quick Installation Guide and this manual 2 Connect the RF Lightning protector to the device and tighten A RF lightning protector 3 Connect antenna to mounting bracket and tighten nut carefully A ...

Страница 64: ...le to both the antenna and the lightning protector connected to the transmitter leaving one loop minimum for a drip loop Ensure the drip loop is lower than the device allowing water to flow away from the device 5 Apply the coaxial sealant around each of the coaxial connections and at the lightning arrestor making sure the RF connections are completely sealed ...

Страница 65: ...l 00809 0200 4705 Rev AB 61 High Gain Remote Antenna Option 6 Attach U bolts to mounting bracket in correct orientation ensuring antenna will be positioned in a vertical position 7 Tighten U bolts to mast and ensure antenna is pointed in a vertical direction ...

Страница 66: ...High Gain Remote Antenna Option May 2017 Reference Manual 00809 0200 4705 Rev AB 62 High Gain Remote Antenna Option ...

Страница 67: ...ay be displayed in the AMS Device Manager and Field Communication together with the location of the Alert in the HART command 48 Additional Status field To view Active Alerts from the Home screen go to Service Tools Active Alerts Table D 1 Device Variable Index Device variable Index 0 Supply voltage 1 Electronics temperature 2 Totalized volume 3 Average flow rate Table D 2 Default Variable Mapping...

Страница 68: ...xceeded the warning threshold value Totalized Volume Stopped Byte 3 Bit 5 The totalized volume accumulation has been suspended by user Sensor Input Life Alert Byte 3 Bit 3 The lifetime pulse count value has exceeded the configured warning threshold HI HI Volume Alert Byte 5 Bit 4 A process value has surpassed the user defined limit HI Volume Alert Byte 5 Bit 5 A process value has surpassed the use...

Страница 69: ......

Страница 70: ...nquiries AP Emerson com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P O Box 17033 Jebel Ali Free Zone South 2 Dubai United Arab Emirates 971 4 8118100 971 4 8865465 RFQ RMTMEA Emerson com Linkedin com company Emerson Automation Solutions Twitter com Rosemount_News Facebook com Rosemount Youtube com user RosemountMeasurement Google com RosemountMeasurement Standa...