background image

www.rosemount.com

¢00825-0100-4648[¤

Quick Installation Guide

00825-0100-4648, Rev CC
February 2012

Rosemount 648 Wireless

Wireless Considerations

Step 1: Physical Installation

Step 2: Verify Operation

Reference Information

Product Certifications

Declaration of Conformity

Start

End

Rosemount 648 Wireless Temperature 
Transmitter

00825-0100-4648_CC.fm  Page 1  Monday, February 13, 2012  12:48 PM

Содержание Rosemount 648

Страница 1: ...825 0100 4648 Rev CC February 2012 Rosemount 648 Wireless Wireless Considerations Step 1 Physical Installation Step 2 Verify Operation Reference Information Product Certifications Declaration of Conformity Start End Rosemount 648 Wireless Temperature Transmitter ...

Страница 2: ...pt any interference received including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons The Power Module may be replaced in a hazardous area The Power Module has surface resistivity greater than one gigaohm and must be properly installed in the wireless device enclosure Care must be taken during ...

Страница 3: ...Active Advertising on the Gateway to ensure that new devices join the network faster For more information see the Smart Wireless Gateway Manual Doc No 00809 0200 4420 Antenna Position The antenna should be positioned vertically either straight up or straight down and it should be approximately 3 ft 1 m from any large structure building or conductive surface to allow for clear communication to othe...

Страница 4: ...housing s conduit entry or Remote Mount where the thermocouple or sensor is mounted separate from the 648 housing then connected to the 648 using conduit Choose the installation sequence that corresponds to the mounting configuration Direct Mount The direct mount installation should not be used when installing with a Swagelok fitting 1 Install the sensor according to standard installation practice...

Страница 5: ...r according to standard installation practices Be sure to use an approved thread sealant on all connections 2 Run wiring and conduit if necessary from the sensor to the 648 3 Pull the wiring through the threaded conduit entry of the 648 4 Attach the sensor wiring to the terminals as indicated on the wiring diagram 5 Connect the Power Module NOTE Wireless devices should be powered up in order of pr...

Страница 6: ... from any large structures or buildings to allow clear communication to other devices STEP 2 VERIFY OPERATION Operation can be verified in four locations at the device via the LCD by using the Field Communicator at the Gateway via the Smart Wireless Gateway s integrated web server or via AMS Suite Intelligent Device Manager Local Display During normal operation the LCD should display the PV value ...

Страница 7: ...he device has joined the network and if it is communicating properly NOTE It may take several minutes for the device to join the network NOTE If the device joins the network and immediately has an alarm present it is likely due to sensor configuration Check the sensor wiring see Rosemount 648 Terminal Diagram on page 9 and the sensor configuration see 648 Fast Key Sequence on page 9 Figure 4 Smart...

Страница 8: ...t match the Network ID and Join Key of the Gateway The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup Network Settings page on the web server see Figure 4 Smart Wireless Gateway Network Settings on page 7 The Network ID and Join Key may be changed in the wireless device by using the following Fast Key sequence If the Field Communicator fails to communicate wit...

Страница 9: ... 3 5 2 Tag Date Descriptor Message Model Model Number I Model Number II Model Number III Write Protect Revision Numbers Transmitter Serial Numbers Device ID Distributor PV Range Values 1 3 4 1 Lower Range Point Upper Range Point Unit Apply Values Lower Sensor Limit Upper Sensor Limit Minimum Span Sensor Trim 1 2 2 1 Lower Sensor Trim Upper Sensor Trim Recall Factory Trim Active Calibrator Wireless...

Страница 10: ...Series 183 Thermocouple Lead Wire Configurations Figure 8 Series 185 Thermocouple Lead Wire Configurations NOTE The wiring diagrams shown above apply only to Rosemount sensors Single Element Type J Type E Type K Type T Type J Type N Type K Red 4 Red 3 White 2 White 1 White 2 Red 3 Purple 2 Red 3 Yellow 2 Red 3 Blue 2 Red 3 Black 2 White 3 Red 2 White 3 Green 2 White 3 ...

Страница 11: ...ification to ensure that they adhere to regulations regarding the use of the RF spectrum Nearly every country requires this type of product certification Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage FCC and IC This device complies with Part 15 of the FCC ...

Страница 12: ...ally Safe and Non incendive when installed in accordance with Rosemount drawing 00648 1000 For use with Rosemount Power Module P N 753 9220 0001 only Enclosure Type 4X IP66 IP67 N5 FM Non incendive and Dust Ignition proof Non incendive for Class I Division 2 Groups A B C and D Dust Ignition proof for Class II III Division 1 Groups E F and G Ambient temperature limits 50 to 85 C For use with Rosemo...

Страница 13: ...Module P N 753 9220 0001 only Intrinsically Safe when installed per Rosemount drawing 00648 1020 1180 Table 3 Sensor Parameters International Certifications I7 IECEx Intrinsic Safety Certificate No IECEx BAS 07 0007X Ex ia IIC T6 Tamb 60 C to 50 C Ex ia IIC T5 Tamb 60 C to 75 C IP66 IP67 Special Conditions for Safe Use X 1 The antenna may present a potential electrostatic ignition hazard and must ...

Страница 14: ...rs are not permitted to change any components insides 4 During installation use and maintenance of the wireless temperature transmitter observe the following standards a GB3836 13 1997 Electrical apparatus for explosive gas atmospheres Part 13 Repair and overhaul for apparatus used in explosive gas atmospheres b GB3836 15 2000 Electrical apparatus for explosive gas atmospheres Part 15 Electrical i...

Страница 15: ...s 15 Radio Power Label see Figure 9 indicates output power configuration of the radio Devices with this label are configured for output power less than 10 mW e i r p At time of purchase the customer must specify ultimate country of installation and operation Radio Power Label Figure 9 ...

Страница 16: ...Quick Installation Guide 00825 0100 4648 Rev CC February 2012 Rosemount 648 Wireless 16 Figure 10 Rosemount 648 Wireless Declaration of Conformity ...

Страница 17: ...Quick Installation Guide 00825 0100 4648 Rev CC February 2012 Rosemount 648 Wireless 17 ...

Страница 18: ...Quick Installation Guide 00825 0100 4648 Rev CC February 2012 Rosemount 648 Wireless 18 ...

Отзывы: