4. Insert the split pins through the bushings and the probe.
5. Secure the split pins.
3.6
Anchor the probe
In turbulent tanks it may be necessary to fix the probe. Depending on the probe type,
different methods can be used to guide the probe to the tank bottom. This may be needed
in order to prevent the probe from hitting the tank wall or other objects in the tank, as well
as preventing a probe from breaking.
Flexible single/twin lead probe
The flexible single lead probe itself can be used for anchoring. Pull the probe rope through
a suitable anchoring point (e.g. a welded eye), and fasten it with a chuck.
Table 3-9: Required Torque and Hex Key Dimensions
Probe
Required torque
Hex key dimension
Flexible twin lead
4.4 ft-lb (6 Nm)
4 mm
Flexible single lead
4 mm wire, stainless
steel
3.7 ft-lb (5 Nm)
4 mm
4 mm wire, Alloy C-276 1.8 ft-lb (2.5 Nm)
3 mm
4 mm wire, Alloy 400
1.8 ft-lb (2.5 Nm)
3 mm
4 mm wire, Duplex
2205
1.8 ft-lb (2.5 Nm)
3 mm
The length of the loop will add to the Blind Zone. The location of the chuck will determine
the beginning of the Blind Zone.
Installation
Reference Manual
February 2020
00809-0100-4308
44
Rosemount 3308 Series
Содержание Rosemount 3308A
Страница 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Страница 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Страница 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Страница 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Страница 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...
Страница 194: ...Product Certifications Reference Manual February 2020 00809 0100 4308 194 Rosemount 3308 Series ...
Страница 222: ...Configuration parameters Reference Manual February 2020 00809 0100 4308 222 Rosemount 3308 Series ...