Emerson Rosemount 2160 Скачать руководство пользователя страница 1

www.rosemount.com

Quick Installation Guide

00825-0100-4160, Rev AC
January 2012

Rosemount 2160

Considerations and Recommendations

Step 1: Physical Installation

Step 2: Verify Operation

Step 3: Reference Information

Product Certifications

EC Declaration of Conformity

Start

End

Rosemount 2160 Wireless
Vibrating Fork Level Switch

Содержание Rosemount 2160

Страница 1: ...v AC January 2012 Rosemount 2160 Considerations and Recommendations Step 1 Physical Installation Step 2 Verify Operation Step 3 Reference Information Product Certifications EC Declaration of Conformity Start End Rosemount 2160 Wireless Vibrating Fork Level Switch ...

Страница 2: ...ing a Field Communicator in an explosive atmosphere ensure the instruments are installed in accordance with intrinsically safe or non incendive field wiring practices Verify that the operating atmosphere of the 2160 is consistent with the appropriate hazardous locations certifications External surface may be hot Care must be taken to avoid possible burns Process leaks could result in death or seri...

Страница 3: ...t be taken during transportation to and from the point of installation to prevent electrostatic charge build up IMPORTANT NOTICE Shipping considerations for wireless products The unit was shipped to you without the power module installed Please remove the power module prior to shipping the unit Each power module contains two C size primary lithium batteries Primary lithium batteries are regulated ...

Страница 4: ...put state to a Dry condition When the 2160 switch is used as a high level alarm the liquid rises in the tank or pipe making contact with the fork which then causes the output state to switch to a Wet condition The switch output state along with other parameters are regularly transmitted over a secure wireless connection to a Smart Wireless Gateway The 2160 continuously performs instrument health d...

Страница 5: ...ft 1 m from any large structure building or conductive surface to allow for clear communication to other devices Electrical Considerations Power Module The Rosemount 2160 is self powered The included power module contains two C size primary lithium thionyl chloride batteries Each battery contains approximately 2 5 grams of lithium for a total of 5 grams in each pack Under normal conditions the bat...

Страница 6: ...nd the housing in accordance with national and local electrical codes The most effective grounding method for the housing is a direct connection to earth ground with minimal impedance Housing Rotation The housing can be rotated for optimal viewing of the optional LCD display and to get the best antenna position Perform the following procedure 1 Loosen the housing rotation set screw Figure 3 2 2 Fi...

Страница 7: ...t Wireless Gateway has been installed and is functioning properly 1 Install the 2160 according to standard installation practices making sure to correctly align the fork using the alignment notch or groove PTFE for NPT and BSPT R Thread Fork Alignment Notch Fork Alignment Groove Gasket for BSPP G Thread Fork Alignment Notch Example Installations Threaded 2160 Installation Flanged 2160 Installation...

Страница 8: ...teway This will result in a simpler and faster network installation 4 Close the housing cover and tighten to safety specification Always ensure a proper seal so that metal touches metal but do not over tighten 5 Position the antenna such that it is vertical either straight up or straight down The antenna should be approximately 3 ft 1 m from any large structures or buildings to allow clear communi...

Страница 9: ...or HART communication A full map of the HART Field Communicator menu is on page 11 NOTE In order to communicate with a Field Communicator power the 2160 by connecting the power module Smart Wireless Gateway Navigate to the Explorer Status page using the Gateway s integrated web interface This page shows whether the device has joined the network and if it is communicating properly NOTE It may take ...

Страница 10: ... Network ID and Join Key and that Active Advertising has been enabled on the Smart Wireless Gateway The Network ID and Join Key in the device must match the Network ID and Join Key of the Gateway The Network ID and Join Key may be obtained from the Gateway on the Setup Network Settings page of the web interface see screenshot below The Network ID and Join Key may be changed in the wireless device ...

Страница 11: ... 6 Band 1 Configure Alert 3 2 Mode 3 Variable 4 Direction 5 Limit 6 Band 1 Configure Alert 4 2 Mode 3 Variable 4 Direction 5 Limit 6 Band 1 Manufacturer 2 Device Type 3 Device Revision 4 Software Revision 5 Hardware Revision 1 Active Alerts 2 History 1 1 PV 1 0 Wet 0 0 Dry 2 PV Status 3 Sensor Frequency 4 Sensor Frequency Status 5 Electronics Temperature 6 Electronics Temperature Status 7 Supply V...

Страница 12: ...RY Output state is forced to Dry when a fault is detected PV Status indicates Fault To change or view the operation mode 1 From the Home screen select 2 Configure 2 Select 2 Manual Setup 3 Select 2 Operation 4 Select 1 Application 5 Select 1 Operation Mode Temperature Units The Unit setting allows the Electronics Temperature process variable to be displayed in Fahrenheit F or Celsius C To view the...

Страница 13: ...t Delay Media Density The frequency of the vibrating fork sensor can be affected by the process liquid density Use Media Density to select one of the following options Normal Select when the liquid specific gravity is between 0 7 and 2 0 Low Select when the liquid specific gravity is less than 0 7 High Select when the liquid specific gravity is greater than 2 0 To change or view the media density ...

Страница 14: ... certification to ensure that they adhere to regulations regarding the use of the RF spectrum Nearly every country requires this type of product certification Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage To see which countries our devices have received ce...

Страница 15: ...ter than one gigaohm To avoid electrostatic build up it must not be rubbed or cleaned with solvents or a dry cloth Canadian Standards Association CSA Approval I6 Certificate Number 06 CSA 1786345 CSA Intrinsically Safe Intrinsically Safe for Class I Division 1 Groups A B C and D Temp Code T3C Intrinsically Safe when installed in accordance with Rosemount drawing 71097 1271 For use with Rosemount S...

Страница 16: ...t the temperature of the electronics housing is in the range of 50 C to 70 C It must not be used outside this range It will be necessary to limit the external ambient temperature if the process temperature is high See Technical Data below 3 Suitably trained personnel shall carry out installation in accordance with the applicable code of practice 4 The user should not repair this equipment 5 If the...

Страница 17: ...ailed above for the T class of the specific flammable gases or vapors present b The surface resistivity of the antenna is greater than 1 gigaohm To avoid electrostatic charge build up it must not be rubbed or cleaned with solvents or a dry cloth c The Rosemount 2160 enclosure is made of aluminum alloy and given a protective epoxy coating however care should be taken to protect it from impact or ab...

Страница 18: ...Quick Installation Guide 00825 0100 4160 Rev AC January 2012 Rosemount 2160 18 Figure 1 EC Declaration of Conformity for Rosemount 2160 ...

Страница 19: ...Quick Installation Guide 00825 0100 4160 Rev AC January 2012 Rosemount 2160 19 ...

Страница 20: ...Quick Installation Guide 00825 0100 4160 Rev AC January 2012 Rosemount 2160 20 ...

Отзывы: