Emerson ROCKPOINTE CF630ORB00 Скачать руководство пользователя страница 22

22

                                                                                                                                                                                                          

ETL Model No.: CF630

EXISTING

WALL  CONTROL

HOT

BLK

TRAVELER 

WIRES

BL

AC

K

LOAD

TRAVELER 

WIRES

BLK

SW406 

FAN/LIGHT

WALL 

CONTROL

SECOND SW406

WALL CONTROL

PURCHASED 

SEPARATELY

BLACK

BL

AC

K

LOAD

SW406 

FAN/LIGHT

WALL 

CONTROL

HOT BLK

BLACK

OFF

....

GROUND

OFF

....

GROUND

8. Wall Control Installation 

(Continued)

8.16

Screw the SW406 Wall Control into Wall Box using the

supplied screws.  Leave the SW406 Wall Control in

“OFF” mode until fan installation is completed. 

8.17

Install the second SW406 Wall Control (sold separately)

into the Wall Box containing the “Load” Wire. Connect

the SW406 Wall Control Black Wire with the Yellow

Label marked “To Power Supply” to the Traveler Wire

from the first Wall Box. Securely connect Wires with

Wire Connector (supplied) (Figure 34).

8.18

Connect the SW406 Wall Control Black Wire  with the

Blue Label marked “To Fan” to the “Load” Black Wire in

the Wall Box. Securely connect Wires with Wire

Connector (supplied) (Figure 34).

8.19

Connect the SW406 Wall Control Green Ground Wire to

the Bare Copper Wire or Green Ground Wire in the Wall

Box. Securely connect Wires with Wire Connector

(supplied) (Figure 34).

8.20

The SW406 Wall Control is supplied with a White, Ivory,

and Almond color Switch Covers. Choose the finish that

best suits your needs and snap the Cover onto the

SW406 Wall Control.

Figure 34

Check to see that all connections are tight and that no

bare wires are visible at the wire connectors.

                           

WARNING

!

STANDARD WIRING FOR EXISTING

3-WAY CONTROLS

3-WAY WIRING DIAGRAM: RETROFIT

3-WAY WIRING DIAGRAM:

NOTE: Retrofit 3-way installations are likely to

include two traveler wires between the two wall

boxes. In new construction, only one traveler wire

Is required (See Figure 34).

Содержание ROCKPOINTE CF630ORB00

Страница 1: ...rts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ROCKPOINTE 54 Wet Location Ceiling Fan Owner s Manual Español página 31 Model Numbers Net Weight 28 8 Lbs CONTEMPORARY CF630ORB00 Oil Rubbed Bronze CF630SW00 Satin White CF630VS00 Vintage Steel ...

Страница 2: ...le electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7kg 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light...

Страница 3: ...the motor facing up The upper styrofoam serves as a holder for the fan during the first stages of assembly PACKAGE CONTENTS 6 3 5 4 1 2 11 10 9 7 8 HARDWARE BAG CONTENTS Part Description Quantity 1 Threaded Studs 8 32 x 1 1 4 2 2 Lockwashers External Tooth 8 2 3 Knurled Knobs 8 32 2 4 Wire Connectors 5 5 Clevis Pin 1 6 Hairpin Clip 1 7 6 32 x 1 2 Truss Head Screws w Lockwashers 6 8 8 32 x 1 4 Wash...

Страница 4: ...Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support ...

Страница 5: ...in Fuse Box before attempting to install the Ceiling Fan on the Outlet Box 3 Ceiling Fan Assembly 3 2 Remove the Hanger Ball by loosening the Phillips Set Screw in the Hanger Ball until the Ball falls freely down the Downrod Figure 1 Remove the Pin from the Downrod then remove the Hanger Ball Retain the Pin and Hanger Ball for reinstallation in Step 3 8 NOTE Do not loosen the screw holding the gre...

Страница 6: ... the Clevis Pin and secure with the Hairpin Clip Figure 4 The Clevis Pin must go through the holes in the Motor Coupler It is critical that the Clevis Pin in the Motor Coupler is properly installed and securely tightened Retighten the Phillips Head Set Screws to secure the Downrod to the Motor Figure 4 It is critical that the clevis pin and set screws in the motor coupler are properly installed an...

Страница 7: ...through the Hanger Ball Reinstall the Hanger Ball Figure 7 on the Downrod as follows Position the Hanger Ball Pin through the two holes in the Downrod and align the Ball so the Pin is captured in the groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the Pin and securely tighten the Set Screw in the Hanger Ball NOTE A loose set screw could create fan wobble HANGER BALL DOWN...

Страница 8: ...e Spacer Attachment Screws from the Motor before installation of blade assemblies Figure 9 Discard the five shipping spacers and spacer screws 8 ETL Model No CF630 8 32 x 1 4 WASHER HEAD SCREWS 3 per blade CEILING FAN BLADES 5 BLADE FLANGES 5 Figure 10 3 11 Your ceiling fan is supplied with one set of five fan blades Mount Blade Flange to Ceiling Fan Blade using three 8 32 x 1 4 Washer Head Screws...

Страница 9: ... the Lower Housing and the Fan Motor Housing A spare 6 32 x 3 8 Truss Head Screw with Lockwasher is provided in hardware bag if needed Figure 12 1 4 20 x 9 16 PAN HEAD SCREW w LOCKWASHER 2 per blade flange assembly BLADE FLANGE ASSEMBLY MOTOR HUB Figure 11 3 12 Loosely attach one Blade Flange Assembly to the Motor Hub by securing the two 1 4 20 x 9 16 Pan Head Screws with Lockwashers supplied Figu...

Страница 10: ...ng A spare 6 32 x 3 8 Truss Head Screw with Lockwasher is provided in hardware bag if needed You have now partially completed the assembly of your new ceiling fan proceed to How to Hang Your Ceiling Fan Final Assembly of the ceiling fan will be completed once ceiling fan is hung and wired LOWER HOUSING LIGHT KIT HOUSING ASSEMBLY 6 32 x 3 8 TRUSS HEAD SCREW WITH LOCKWASHER Figure 14 LIGHT KIT HOUSI...

Страница 11: ...commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 15 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wi...

Страница 12: ...ued 4 3 Carefully lift the fan and seat the Hanger Ball Downrod Assembly on the Hanger Bracket that was just attached to the Outlet Box Figure 18 Be sure the Groove in the Ball is engaged with the Anti Rotation Tab on the Hanger Bracket Figure 18 4 2 Securely attach the Hanger Bracket to the Outlet Box using the two Screws supplied with the Outlet Box Figure 17 Hanger bracket must seat firmly agai...

Страница 13: ...ed for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible e...

Страница 14: ...O MOTOR N Wire using the Wire Connector supplied Figure 21 T O M O T O R L FOR LIGH T AC IN N AC IN L TO M O TO R N RECEIVER BLACK WIRE SUPPLY BLACK WIRE RECEIVER RED WIRE RECEIVER BLUE WIRE FAN MOTOR BLACK WIRE FAN MOTOR BLUE WIRE Figure 22 5 4 Securely connect the Supply Black Wire Hot Wire to the Receiver Black AC IN L Wire using the Wire Connector supplied Figure 22 Securely connect the Fan Mo...

Страница 15: ...the hangerball nestled in the hanger bracket Figure 23 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 5 How to Wire Your Ceiling Fan Continued GREEN GROUND WIRE FROM HANGER BRACKET TO M O T O R L GROUND WIRE GREEN GR...

Страница 16: ...til it stops Figure 26 NOTE Periodically check that the Glass Shade is seated fully clockwise in the Light Kit Housing Assembly GLASS SHADE LIGHT KIT HOUSING ASSEMBLY RAISED DIMPLES 3 GLASS SHADE FLAT AREA 3 To avoid the risk of fire use 13 Watt bulbs maximum WARNING 6 Final Assembly 6 3 Note This step may need an additional person for installation of the Decorative Grill Position the Decorative G...

Страница 17: ...n the Ceiling Cover Figure 29 Secure the Ceiling Cover in place by sliding the 8 Lockwashers and 8 32 Knurled Knobs supplied onto the Threaded Studs Figure 29 Tighten the Knurled Knobs securely until the Ceiling Cover fits snugly against the ceiling and the hole in the Ceiling Cover is clear of the downrod 6 4 Screw the two 8 32 x 1 1 4 Threaded Studs supplied into the tapped holes in the Hanger B...

Страница 18: ...in the ON up position Change the switch settings as follows NOTE Do not duplicate the code of an existing control of an installed ceiling fan within 100 feet 7 3 Slide the five switch levers in the SW406 Wall Control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 7 4 The sixth switch marked ON and I is for dimming control ...

Страница 19: ...er NOTE Make all wiring connections using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 8 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan SW406 Wall Control into the outlet box 8 2 Remove faceplat...

Страница 20: ...32 8 7 Screw the SW406 Wall Control into Wall Box using the supplied screws Leave the SW406 Wall Control in OFF mode until fan installation is completed 8 8 The SW406 Wall Control is supplied with a White Ivory and Almond color Switch Covers Choose the finish that best suits your needs and snap the Cover onto the SW406 Wall Control Figure 32 8 9 Install Decorator Wall Plate using the two screws pr...

Страница 21: ... Control place the SW406 Wall Control in OFF mode by pushing ON OFF switch to the OFF position 8 13 Install the first SW406 Wall Control in the Wall Box containing the Hot Wire Connect the SW406 Wall Control Black Wire with the Yellow Label marked To Power Supply to the Hot Wire in the Wall Box Securely connect the Wires with the Wire Connector supplied Figure 33 8 14 Connect the SW406 Wall Contro...

Страница 22: ...gure 34 8 18 Connect the SW406 Wall Control Black Wire with the Blue Label marked To Fan to the Load Black Wire in the Wall Box Securely connect Wires with Wire Connector supplied Figure 34 8 19 Connect the SW406 Wall Control Green Ground Wire to the Bare Copper Wire or Green Ground Wire in the Wall Box Securely connect Wires with Wire Connector supplied Figure 34 8 20 The SW406 Wall Control is su...

Страница 23: ...sition Within one minute of flipping the switch to ON push and hold the FAN OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan lights if installed will blink to indicate the SW406 Wall Control code has been paired with the receiver 9 2 If programming is unsuccessful retry the above instructions after cycling the SW406 Wall Control ON OFF switch to restart the 1 minute pr...

Страница 24: ...SW406 Wall Control WARNING HIGH TO LOW BUTTONS ON OFF SWITCH O OFF ON LIGHT BUTTON FAN BUTTON POWER INDICATOR LIGHT OFF ON Figure 35 10 Using Your Ceiling Fan 10 2 Restore electrical power to the outlet box by turning the electricity on at the main fuse box All fans are shipped from the factory with the Reverse Switch positioned to the left circulate air downward If airflow is desired in opposite ...

Страница 25: ... part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in ...

Страница 26: ...HARDWARE BAG OFF ON OFF ON OFF ON 15 3 1 2 5 16 8 9 11 21 24 25 7 6 10 10 13 19 18 20 17 7 6 5 4 26 27 14 12 13 8 9 11 11 12 23 22 Not Shown OFF 26 ETL Model No CF630 14 Repair Parts ...

Страница 27: ...lip 1 10 6 32 x 1 2 Truss Head Screws w Lockwashers 6 11 6 32 x 3 8 Truss Head Screw w Lockwasher spares 2 12 1 4 20 x 9 16 Pan Head Screws w Lockwashers 11 13 8 32 x 1 4 Washer Head Screws 16 14 Blade Balance Kit 1 15 Ceiling Cover 1 764818 ORB 764818 SW 764818 VS 16 Motor Coupler Cover 1 764819 ORB 764819 SW 764819 VS 17 Motor Hub 1 764821 764821 764821 18 Flange Set Set of 5 764822 ORB 764822 S...

Страница 28: ... screws securely 3 Fan wobbles 1 Set screws in motor coupler is loose 1 Tighten the set screws securely in the motor or shakes coupler excessively 2 Set screw in hanger ball downrod 2 Tighten the set screw in the hanger ball downrod assembly is loose assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan motor are loose blade flanges to the motor are tight 4...

Страница 29: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 30: ...EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP75210000 Form No BP7521 Revision 170213 ETL Model No CF630 Printed in China 02 17 SERIAL NUMBER DATE CODE The serial number of this fan can be found on the nameplate on top of the fan housing The date code can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above an...