Quantum MP User Guide
15
Issue: A4 www.emersonct.com
3.3 Terminal cover removal
3.3.1 Removing the terminal covers
Both size 1 and size 2 drives are installed with one control terminal cover.
Figure 3-1 Removing the control terminal cover - Size 1 shown
3.3.2 Removing the finger-guard and break-outs
Figure 3-2 Removing the finger-guard break-outs
Place finger-guard on a flat solid surface and hit relevant break-outs with
hammer as shown (1). Continue until all required break-outs are removed
(2). Remove any flash / sharp edges once the break-outs are removed.
Isolation device
The AC supply must be disconnected from the drive using an
approved isolation device before any cover is removed from
the drive or before any servicing work is performed.
Stored charge
The drive contains capacitors that remain charged to a
potentially lethal voltage after the AC supply has been
disconnected. If the drive has been energized, the AC
supply must be isolated at least ten minutes before work
may continue.
WARNING
WARNING
Pozi Pz2
1
2
All sizes