background image

Before installation these instructions must be read fully and understood

Product warranty

Emerson warrants its Penberthy products 
as designed and manufactured to be free 
of defects in the material and workmanship 
for a period of one year after the date of 
installation or eighteen months after the date 
of manufacture, whichever is earliest. Emerson 
will, at its option, replace or repair any products 
which fail during the warranty period due to 
defective material or workmanship.

Prior to submitting any claim for warranty 
service, the owner must submit proof of 
purchase to Emerson and obtain written 
authorization to return the product. Thereafter, 
the product shall be returned to Emerson with 
freight paid.

This warranty shall not apply if the product has 
been disassembled, tampered with, repaired or 
otherwise altered outside of Emerson's factory 
or if it has been subject to misuse, neglect or 
accident.

The responsibility of Emerson hereunder is 
limited to repairing or replacing the product 
at its expense. Emerson shall not be liable 
for loss, damage or expenses related directly 
or indirectly to the installation or use of 
its products, or from any other cause or 
for consequential damages. It is expressly 
understood that Emerson is not responsible 
for damage or injury caused to other products, 
buildings, personnel or property, by reason of 
the installation or use of its products.

PENBERTHY

 SERIES H FLAT GLASS GAGES

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TABLE OF CONTENTS

Product warranty ................................................ 1
1.  About the manual .......................................... 2
2. Introduction ................................................... 2
  2.1  System description ................................. 2
3.  Available models ........................................... 2
  3.1   Design ratings at maximum and 

minimum operating temperatures ....... 3

4. Inspection ...................................................... 4
  4.1  Glass inspection ..................................... 4
  4.2  User rating inspection............................ 4
5. Installation ..................................................... 4
  5.1  Piping strain ............................................ 4
  5.2  Differential thermal expansion.............. 4
  5.3  Mirror viewing ......................................... 4
  5.4  Nut retorquing ........................................ 5
  5.5  Belleville washers .................................. 5
6. Operation ....................................................... 5
  6.1  Hydrostatic test ...................................... 6
7. Maintenance .................................................. 6
  7.1  Maintenance procedures ....................... 6
  7.2 Troubleshooting ..................................... 7
8.  Removal - disassembly - reassembly ......... 7
  8.1 Disassembly ........................................... 7
  8.2  Inspection of glass seating surfaces .... 8
  8.3 Reassembly ............................................ 8
9.  Disposal at end of useful life ........................ 9
10. Telephone assistance ................................... 9
11. Exploded parts diagrams ............................ 10

valves.emerson.com

© 2017 Emerson. All rights reserved.

VCIOM-04073-EN 17/05

Tables and figures

Table 1  Design ratings of RH and RHR gage .. 3
Table 2  Design ratings of TH and THR gage ... 3
Table 3   Design ratings of TH and 

THR gage - 316 STS covers................. 3

Table 4  Bolt torque values ............................... 5
Figure 1 Nut tightening sequence ..................... 5
Figure 2 Belleville washer position ................... 5
Figure 3 Gage disassembly ................................ 7
Figure 4 Nut loosening sequence ..................... 7
Figure 5  Exploded parts diagram of 

transparent gage ............................... 10

Figure 6  Exploded parts diagram of 

reflex gage ......................................... 10

This is Emerson’s sole warranty and in lieu of 
all other warranties, expressed or implied which 
are hereby excluded, including in particular all 
warranties of merchantability or fitness for a 
particular purpose.

This document and the warranty contained 
herein may not be modified and no other 
warranty, expressed or implied, shall be made 
by or on behalf of Emerson unless made in 
writing and signed by the company's general 
manager or director of engineering.

Содержание PENBERTHY H Series

Страница 1: ...TABLE OF CONTENTS Product warranty 1 1 About the manual 2 2 Introduction 2 2 1 System description 2 3 Available models 2 3 1 Design ratings at maximum and minimum operating temperatures 3 4 Inspection 4 4 1 Glass inspection 4 4 2 User rating inspection 4 5 Installation 4 5 1 Piping strain 4 5 2 Differential thermal expansion 4 5 3 Mirror viewing 4 5 4 Nut retorquing 5 5 5 Belleville washers 5 6 Op...

Страница 2: ...e six basic components Each component may vary slightly depending on the desired physical and mechanical properties for the gage Use the exploded parts view in Section 11 as additional reference material Chamber provides a pressure retaining metallic channel for the liquid to enter and be viewed Slot s are machined into the chamber to provide direct visualization of the process fluid Gaskets seal ...

Страница 3: ...kPa at 600 F 316 C Top chem 2000 4 9 1610 psig 11100 kPa at 20 F 29 C to 100 F 38 C 100 psig 690 kPa at 500 F 260 C 25 glass filled PTFE 4 9 650 psig 4480 kPa at 20 F 29 C to 100 F 38 C 150 psig 1030 kPa at 500 F 260 C NBR Buna N 4 9 300 psig 2070 kPa at 20 F 29 C to 100 F 38 C 225 psig 1550 kPa at 250 F 121 C FKM Viton 4 9 300 psig 2070 kPa at 20 F 29 C to 100 F 38 C 180 psig 1240 kPa at 400 F 20...

Страница 4: ...be vulnerable to dust grit tools and any other objects which may scratch chip or break the glass WARNING DO NOT use glass that is chipped or even slightly scratched Glass surface defects weaken the glass which may result in glass breakage and fluid loss under pressure resulting in serious personal injury or property damage 4 2 User rating inspection The user should confirm that 1 The Series H liqu...

Страница 5: ...BLE 4 BOLT TORQUE VALUES Gage models and gasket material Bolt torque ft lb Nm RH RHR TH and THR w Grafoil standard 30 to 35 41 to 48 RH RHR TH and THR w non asbestos optional 45 to 50 61 to 68 Top chem 2000 30 to 35 41 to 48 PTFE Teflon and PCTFE Kel F 20 to 25 27 to 34 25 glass filled PTFE Teflon 19 to 22 26 to 30 All models with FKM Viton or elastomeric optional 10 to 15 14 to 20 TH THR with PCT...

Страница 6: ...ce with their specific application If bolting gasketing or glass on any section of a multi section gage is disturbed all sections must be checked for integrity and retorqued or repaired as necessary On all installations the following items should be evaluated regularly by the user for purposes of maintenance 1 Glass for cleanliness and signs of damage or wear 2 Shields if used for signs of cloudin...

Страница 7: ...heck application to determine actual operating conditions and contact an authorized Penberthy distributor on how to proceed FIGURE 3 FIGURE 4 Nut loosening sequence 1 Lay transparent style gage on cut pieces of wood as shown in Figure 3 to keep it from rolling on the opposite side s cover s or lay reflex style gage on bench so nut side of fastener is up 2 Hold gage firmly loosen nuts starting at b...

Страница 8: ...ve all paint rust and scale Apply a light coat of oil to the threads 2 For transparent gages insert bolts through half the cover and lay out covers on cut 1 x 4 pieces of wood along the bench side by side with the liquid chamber Use chamber to space covers and line them up with vision slots 3 For reflex style and belleville reflex style gages lay out covers on cut 1 x 4 pieces of wood along bench ...

Страница 9: ...fferent torque value The center set s of bolts will have a final torque value of 35 ft lb 47 Nm The second two pair of bolts outward toward the end of the gage will be torqued to 30 ft lb 41 Nm the third two pair to 25 ft lb 34 Nm etc until all pairs have been torqued Refer to Section 5 for installation and Section 6 for operation of liquid level gage when returning to service 9 DISPOSAL AT END OF...

Страница 10: ...et 8 Cushion 9 Shield 100 Bolt U bolt 125 Washer 163 Nameplate 331 Band RECOMMENDED SPARE PARTS Item Description Qty 100 Bolt U bolt 2 per sect 4 Nut 2 per sect 48 Glass 1 7 Gasket 2 8 Cushion 2 9 Shield if used 2 FIGURE 5 Transparent FIGURE 6 Reflex 11 EXPLODED PARTS DIAGRAMS NOTE Size 9 shown actual gage may be shorter and require fewer bolting components ...