PACMotion VFD Syllabus
Section 15
GFK-3167B
December 2020
PACMotion VFD Demo Case Details (Note 11)
66
15.3
PACMotion VFD Demo Case and Factory Reset
Resetting the PACMotion VFD to Factory defaults
1.
If necessary, you can reset the parameters VFD to factory defaults
Figure 61: Reset Parameters to Factory Defaults
Setting the following PACMotion VFD Parameters for PROFINET Demo Case Operation
2.
Set the following Parameters for PROFINET Operation:
A file containing these settings can be found in Application Note 7.
They can be downloaded using the PACMotion VFD Studio. The file name is:
VFD_S2_230V_0.75kW_V2.50_DemoCase.ptl
Parameter
Value
Definition
P1-14
201
Extended menu access (201=all parameters)
P4-02
1
Autotune (1=enable, VFD will set back to 0)
P1-07
230
Motor rated voltage (AC Volts)
P1-08
0.4
Motor rated current (Amps)
P1-09
60
Motor rated frequency (Hz)
P1-10
1600
Motor rated speed (RPM)
P1-12
4
Primary command source (4 = Fieldbus)
P2-13
0
AO2 Output 2 function (DO2 = 24VDC)