Effect of Flow Direction on frequency outputs
Flow Direction
affects how the transmitter reports flow values via the frequency outputs. The
frequency outputs are affected by
Flow Direction
only if
Frequency Output Process Variable
is set
to a flow variable.
Effect of the Flow Direction parameter and actual flow direction on
frequency outputs
Table 4-6:
Flow Direction
setting
Actual flow direction
Forward
Zero flow
Reverse
Forward
Hz > 0
0 Hz
0 Hz
Reverse
0 Hz
0 Hz
Hz > 0
Bidirectional
Hz > 0
0 Hz
Hz > 0
Absolute Value
Hz > 0
0 Hz
Hz > 0
Negate Forward
0 Hz
0 Hz
Hz > 0
Negate Bidirectional
Hz > 0
0 Hz
Hz > 0
Effect of Flow Direction on discrete outputs
The
Flow Direction
parameter affects the discrete output behavior only if
Discrete Output
Source
is set to
Flow Direction
.
Effect of the Flow Direction parameter and actual flow direction on
discrete outputs
Table 4-7:
Flow Direction
setting
Actual flow direction
Forward
Zero flow
Reverse
Forward
OFF
OFF
ON
Reverse
OFF
OFF
ON
Bidirectional
OFF
OFF
ON
Absolute Value
OFF
OFF
OFF
Negate Forward
ON
OFF
OFF
Negate Bidirectional
ON
OFF
OFF
Effect of Flow Direction on digital communications
Flow Direction
affects how flow values are reported via digital communications.
Configure process measurement
44
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Содержание MICRO MOTION 2700
Страница 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 142: ...Integrate the meter with the control system 134 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 154: ...Set up the Weights Measures application 146 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 156: ...Operations maintenance and troubleshooting 148 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 327: ...Device Tools Trending Figure C 24 Using ProLink III with the transmitter Configuration and Use Manual 319 ...
Страница 328: ...Using ProLink III with the transmitter 320 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 373: ......