background image

Type HSR

Emerson Automation Solutions

T80573-2A 

6

7

4

8

16

22

15

27

9

17

23

5

10 14 25

1

26

13

12

11

2

3

Americas

 

McKinney, Texas 75070 USA 

T   +1 800 558 5853 

+1 972 548 3574

Europe

 

Bologna 40013, Italy 

T  +39 051 419 0611

Asia Pacific

 

Singapore 128461, Singapore 

T  +65 6777 8211

Middle East and Africa 

Dubai, United Arab Emirates 

T  +971 4 811 8100

 [email protected]

 Fisher.com

 Facebook.com/EmersonAutomationSolutions

 LinkedIn.com/company/emerson-automation-solutions

 Twitter.com/emr_automation

D103075X012 © 2003, 2019 Emerson Process Management Regulator 

Technologies, Inc. All rights reserved. 06/19.

The Emerson logo is a trademark and service mark of Emerson 

Electric Co. All other marks are the property of their prospective owners. 

Fisher™ is a mark owned by Fisher Controls International LLC, a 

business of Emerson Automation Solutions. 

The contents of this publication are presented for informational purposes 

only, and while every effort has been made to ensure their accuracy, 

they are not to be construed as warranties or guarantees, express or 

implied, regarding the products or services described herein or their use 

or applicability. All sales are governed by our terms and conditions, which 

are available upon request. We reserve the right to modify or improve the 

designs or specifications of such products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not 

assume responsibility for the selection, use or maintenance of any 

product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management Regulator Technologies, Inc. product 

remains solely with the purchaser.

damage to regulator parts, leaks in the 

regulator or personal injury due to bursting 

of pressure-containing parts or explosion 

of accumulated gas.

Type HSR regulators provide internal relief that limits the 

total outlet pressure buildup over setpoint. This internal relief 

may be adequate for the application, if not, provide additional 

pressure relief or a pressure-limiting device downstream. 

Regulators should be inspected for damage after any 

overpressure condition.

!

WARNING

To avoid personal injury or property damage 

due to explosion or damage to regulator or 

downstream components during startup, 

release downstream pressure to prevent an 

overpressure condition on the diaphragm of 

the regulator.
In order to avoid an overpressure condition 

and possible equipment damage, pressure 

gauges should always be used to monitor 

pressures during startup.

Startup

With proper installation completed, slowly open the 

shutoff valve. Check all connections for leaks. Check the 

downstream equipment for proper operations.

Adjustment

To increase the outlet pressure setting, turn the adjusting 

screw clockwise. To reduce the outlet pressure setting, turn 

the adjusting screw counterclockwise. A pressure gauge 

should always be used to monitor downstream pressure 

while adjustments are being made. Do not adjust the 

spring to produce an outlet pressure setting above the limit 

identified on the information label. If the required pressure 

setting is not within the range of the spring being used, 

substitute with the correct spring. When changing the spring, 

also change the range identified on the information label 

to indicate the actual pressure range of the spring in use. 

After the spring adjustment has been completed, replace the 

closing cap.

Parts List

Key Description

Spring Case Assembly

Lower Casing

3 Screen
4 Lever
5 Stem

Straight Pin

Machine Screw (2 required)

Closing Cap

Machine Screw (8 required)

10 

Relief Valve Spring

11 Diaphragm

Key Description 

12 

Pusher Post

13 

Lower Spring Seat

14 

Relief Spring Retainer

15 Body
16 O-ring
17 

Cap Screw (2 required)

22 Orifice
23 Disk
25 Spring
26 

Adjusting Screw

27 

Information Label

Figure 1

. Type HSR Regulator Assembly