Emerson HF948BS01 Скачать руководство пользователя страница 2

2

WARNING:

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service

panel disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a warning
device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan.

Always turn off the power to the ceiling fan before servicing.

4. Suitable for use with solid-state speed controls.

5. Do not bend the blade flanges when installing the blades, balancing the blades, or

cleaning the fan. Do not insert foreign objects in between the rotating blades.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before

wiring, and do not operate fan without blades.

2. All wiring must satisfy National and Local Electrical Codes. Use the National

Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a
precaution against possible electrical shock. Electrical installation should be made
or approved by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably

supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 50 lbs or less”, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are not
acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.

4. The fan must be mounted with the fan blades at least 10 feet from the floor to

prevent accidental contact with the fan blades.

5. Suitable for use with solid-state speed controls.
6. Always properly connect the retention cable included with this fan (follow the

“Installation Instructions” section carefully).

7. The support beam or joist must be secure and capable of supporting at least 50

pounds.

8. Follow the recommended instructions for the proper method of wiring your ceiling

fan. If you do not know enough about electrical wiring, have your fan installed by a
licensed electrician.

WARNING:

To avoid fire, shock or injury, do not use an Emerson or any other brand

of control not specifically approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this

product and/or any accessories designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or accessories not designated for use with
this product by Emerson Electric Co. could result in personal injury or property
damage.

WARNING:

To reduce the risk of personal injury, do not bend the blade flange when

installing the blade flanges, balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

WARNING:

To reduce the risk of electric shock, this fan must be installed with an

isolating wall control/switch.

!

WARNING

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.

U.L. Model No.: HF948, HF956

BP7311-2 48 56" Heat Fans  9/7/10  3:25 PM  Page 2

Содержание HF948BS01

Страница 1: ...nce freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or f...

Страница 2: ... outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades 5 Suitable for use with solid state speed controls 6 Always properly connect the retention cable included w...

Страница 3: ...Intermixing blades between fans can cause excessive wobble Keep blades in original sets of three Fan Assembly Instructions 1 Put the upper canopy and lower canopy on the hanger pipe assembly facing in the proper direction See Figure 1 NOTE For HF948 Only If you are going to use the 8 pipe first remove the hanger assembly from the 22 pipe and install it on the 8 pipe Be sure that the nut is securel...

Страница 4: ...t in the fan falling WARNING To reduce the risk of personal injury do not bend the blade flanges when installing the blades balancing the blades or cleaning the fan Do not insert foreign objects between rotating fan blades WARNING BLADE BLADE GASKET SPRING WASHER 2 PER BLADE M6 x 1 2 SCREW 2 PER BLADE Figure 3 3 Align the clevis pin holes in the hanger pipe with the holes in the motor yoke Install...

Страница 5: ...ing off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of fire electric shock or personal injury a The fan must be hung with at...

Страница 6: ...UND WIRE BLACK SUPPLY HOT BLACK FAN WIRE GREEN WIRE GROUND FROM FAN WIRE CONNECTORS 3 WHITE SUPPLY NEUTRAL WHITE FAN WIRE Figure 9 2 Lift the fan onto the J hook and position as shown in Figure 7 Make sure the motor wires and retention cable at the top of the hanger pipe are positioned behind J hook as illustrated in Figure 7 CAUTION The electrical wires and retention cable must not be placed betw...

Страница 7: ...as a result of tight cable if this should happen shut off power supply and re check instructions to correct problem NOTE When any solid state motor speed control is used a humming noise may be present in the fan on low speed This hum in no way affects the operation of the fan and is acceptable in most industrial installations To avoid possible electrical shock be sure electricity is turned off at ...

Страница 8: ... Setscrews 2 ea 10 Hairpin Clip 11 Clevis Pin 12 Cable Clamp 2 each 13 Screw M6 x 1 2 6 each 14 Spring Washer M6 6 each 15 Blade Gasket 3 each 16 Wire Connector 3 each 17 Allen Wrench Owner s Manual BP7311 2 BP7311 2 BP7311 2 BP7311 2 BP7311 2 Repair Parts Listing 1 2 4 5 6 10 11 17 13 12 16 14 7 15 8 9 3 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPA...

Отзывы: