background image

Type N201

D450003T012

Instruction Manual

MCK-1023

March 2009

www.emersonprocess.com/regulators/lp

!

Warning

install, use, and maintain this equipment  

according to manufacturer’s instructions 

and all federal, state, local laws and 

codes, and nFPa Pamphlet 58.  Periodic 

inspection and maintenance is essential.  

 

introduction

Type N201 automatic cylinder filling valve is supplied 

completely piped up, and consists of a filler valve 

assembly, two Type 67 regulators with pressure 

gauges, a trip valve, and special parts for alternate 

scale installations.  

 

Principle of Operation

Refer to Figure 2.  Supply pressure registers at 

regulators 1 and 2.  Pressure from regulator 1 

registers beneath the lower diaphragm of the filler 

valve, see “A” in Figure 2.  This pressure holds the 

lower valve closed, preventing pressure from regulator 

2 from registering on the upper diaphragm.  Spring 

force holds the upper valve open, and liquid from the 

charging pump can enter the cylinder to be filled. 
When the cylinder reaches the predetermined weight 

set on the scale, the beam button on the scale beam 

contacts the trip valve, see “B” in Figure 2.  The trip 

valve opens to exhaust pressure from under the 

lower diaphragm.  Spring force opens the lower valve, 

allowing pressure from regulator 2 to register on the 

upper diaphragm.  This closes the upper valve, and 

stops flow through the orifice.  A red button indicates 

that the filler valve is closed and that the cylinder is full.  

Removing the full cylinder from the scale closes the trip 

valve and permits the system to reset itself for the 

next cylinder.

installation

Refer to Figure 3.  

 

  1.  Connect the top 1/2 FNPT connection “C” of 

       the filler valve to the charging manifold.  

 

  2.  Determine if the trip valve hose is long enough to 

       reach the scale frame as shown.  If not, insert 

       1/8-inch (3,2 mm) pipe as needed.
  3.  Standard trip valve installation (also see alternate

       methods, 3.A and 3.B): 

 

       a.  The trip valve should be installed at 

            approximately 1/5 of the scale beam length, 

            measured from the pivot point to the beam 

            stop.  Although the trip valve can be installed

            to operate directly off the scale beam, it is not

            recommended because of the side play in

            most scale beams can resuIt in failure to

            contact the trip valve.  

 

Figure 1.

  Type N201 Automatic Cylinder Filling Valve

Type n201 automatic Cylinder Filling Valve

P1090

Содержание Fisher N201 Series

Страница 1: ...e scale beam contacts the trip valve see B in Figure 2 The trip valve opens to exhaust pressure from under the lower diaphragm Spring force opens the lower valve allowing pressure from regulator 2 to register on the upper diaphragm This closes the upper valve and stops flow through the orifice A red button indicates that the filler valve is closed and that the cylinder is full Removing the full cy...

Страница 2: ...ade This is usually necessary when both 20 pounds 9 kg and 100 pounds 45 kg cylinders are to be filled Follow steps 3 a b c and d Place the beam button J on the scale beam close enough to the pivot point to allow the slide weight to move to zero If there is not enough room to permit this either the beam button must be ground down or the user must make a special beam button e Mount beam bar K on th...

Страница 3: ...int d Attach the beam bar L to the clamp M with two screws and attach the clamp to the rear of the scale beam with two screws e Remove locknut D and insert the trip valve through the 5 8 inch 16 mm hole Replace locknut f Using locknut D and E position trip valve so that it barely contacts the beam bar L with the scale in a level position 4 Connect supply pressure air or gas at point P Recommended ...

Страница 4: ...lide beam weight H to the tare weight stamped on the cylinder open the hose shutoff valve and the cylinder valve and the Type N201 will fill the cylinder to the weight added on the scale pan Note When operating with high pump pressure the filler valve may close off then reopen for a short spurt and close off again This is due to the force of the incoming liquid stream If the proper cylinder weight...

Страница 5: ...Type N201 5 Figure 4 Type N201 Assemblies CH1624 11 button and bar for Attachment to scale beam 15 10 9 18 20 19 5 3 7 6 8 1 21 34 33 38 40 36 37 23 46 25 45 39 22 17 16 14 32 35 13 45 2 42 44 43 41 24 ...

Страница 6: ...bling To Reassemble 1 Replace orifice key 3 in valve head key 1 2 Replace O ring key 7 and screw in bushing key 8 3 Replace disk holder assembly key 5 and spring key 21 Screw the disk holder into the diaphragm head key 9 4 Replace upper diaphragm key 10 on the valve head key 1 Align the valve housing key 2 spring key 35 lower diaphragm assembly key 32 and valve body key 17 so that the cap screws k...

Страница 7: ...ip Valve Body Brass 1F945014012 25 Inner Valve Brass 20B9389X012 28 Pipe Plug Steel not shown 1A3619X0012 32 Diaphragm Assembly 1H1615000A2 33 Pipe Nipple 3 required 1C488226232 34 Tee Malleable iron 1C597547362 35 Spring Steel 1F944627212 36 Compression Elbow Brass 2 required 15A6002X172 37 Nut 2 required 1H262224122 38 Hose Assembly 1J152299012 39 Tubing Assembly Copper T20048000A2 40 Street Elb...

Страница 8: ...n or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Emerson Pr...

Отзывы: