Table 2. easy-Drive RPU-100 Modbus Map (cont.)
Type
Name
MB Register
Default
R/W
Values
Notes
uint16
RESERVED
44106
uint16
RESERVED
44107
uint16
RESERVED
44108
uint16
RESERVED
44109
uint16
RESERVED
44110
uint32
PCB serial number
44111, 44112
0
R/W*
0 - 4,294,967,295 PCB serial number
uint32
PCB revision
44113, 44114
0
R/W*
0 - 4,294,967,295 PCB revision
uint16
Flash Firmware major revision
44115
0
R
0 - 65535
From flash firmware when compiled
uint16
Flash Firmware minor revision
44116
0
R
0 - 65535
From flash firmware when compiled
uint16
Flash Firmware mod revision
44117
0
R
0 - 65535
From flash firmware when compiled
uint16
Flash Firmware build revision
44118
0
R
0 - 65535
From flash firmware when compiled
uint16
Boot Firmware major revision
44119
0
R
0 - 65535
From boot firmware when compiled
uint16
Boot Firmware minor revision
44120
0
R
0 - 65535
From boot firmware when compiled
uint16
Boot Firmware mod revision
44121
0
R
0 - 65535
From boot firmware when compiled
uint16
Boot Firmware build revision
44122
0
R
0 - 65535
From boot firmware when compiled
uint32
PCB test date
44123, 44124
0
R/W*
0 - 4,294,967,295
Seconds since January 1, 2000,
Board Supplier Functional Test Date
uint32
System completion date
44125, 44126
0
R/W*
0 - 4,294,967,295
Seconds since January 1, 2000,
Final Assembly Test Date
uint16
RESERVED
44127
uint16
RESERVED
44128
uint16
RESERVED
44129
uint16
RESERVED
44130
uint16
RESERVED
44131
uint16
RESERVED
44132
uint16
RESERVED
44133
uint16
RESERVED
44134
uint16
RESERVED
44135
uint16
RESERVED
44136
uint16
RESERVED
44137
uint16
RESERVED
44138
uint16
RESERVED
44139
uint16
RESERVED
44140
uint16
RESERVED
44141
uint16
RESERVED
44142
uint16
RESERVED
44143
uint16
RESERVED
44144
uint16
RESERVED
44145
uint16
RESERVED
44146
uint16
RESERVED
44147
uint16
Reset to factory defaults
44148
0
R/W
0 - 1
Value of 1 will reset all setup registers to factory
defaults. Will automatically set back to 0.
uint16
Reset statistics
44149
0
R/W
0 - 1
Value of 1 will clear all statistic registers (44011 -
44017). Will automatically set back to 0.
1. uint is defined as Unsigned Integer
uint16 – unsigned 16 bit variable, can take value 0-65535.
uint32 – unsigned 32 bit variable, can take value 0-4294967295.
(Reserved) – registers used for development use only.
R/W* - writable in manufacturing.
† - 32bit register contains data that spans two registers – reads and write of data needs
to be performed within the same Modbus command function to ensure coherency of
data.
Содержание Fisher easy-Drive RPU-100
Страница 20: ...Instruction Manual D104551X012 easy Drive RPU 100 May 2021 20 Appendix B Certificate of Conformance continued ...
Страница 21: ...Instruction Manual D104551X012 easy Drive RPU 100 May 2021 21 Appendix B Certificate of Conformance cont ...
Страница 22: ...Instruction Manual D104551X012 easy Drive RPU 100 May 2021 22 ...
Страница 23: ...Instruction Manual D104551X012 easy Drive RPU 100 May 2021 23 ...