Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual 

1

. . . . . . . . . . . . . . . . . . . . . . . . .

Description 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Packing Maintenance 

7

. . . . . . . . . . . . . . . . . . . . .

Replacing the Seal Ring Assembly

11

. . . . . . . . .

Replacing the Disk, Shafts, or Bearings

11

. . . . .

Actuator Mounting 

15

. . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering 

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Kits

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts List 

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction

Scope of Manual

This instruction manual includes installation,
maintenance, and parts information for the Fisher
8580 valve, DN50 through DN300 or NPS 2 through
NPS 12 (figure 1). Refer to separate instruction
manuals for information covering the power on-off
actuator and accessories.

Do not install, operate, or maintain an 8580 valve
without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and
maintenance. To avoid personal injury or property
damage, it is important to carefully read, understand,
and follow all the contents of this manual, including
all safety cautions and warnings. If you have any
questions about these instructions, contact your
Emerson Process Management sales office before
proceeding.

Figure 1. Fisher 8580 Valve with 2052 Actuator 

and DVC6000 Digital Valve Controller

W9425

SINGLE FLANGE STYLE

WAFER STYLE

W9498

Instruction Manual

D103300X012
March 2010

8580 Valve

Содержание Fisher 8580

Страница 1: ...uction manuals for information covering the power on off actuator and accessories Do not install operate or maintain an 8580 valve without being fully trained and qualified in valve actuator and accessory installation operation and maintenance To avoid personal injury or property damage it is important to carefully read understand and follow all the contents of this manual including all safety cau...

Страница 2: ...g 1 of Class IV per ANSI FCI 70 2 and IEC 60534 4 Flow Direction Standard forward flow is with the seal retainer facing upstream reverse flow is permissible within specified pressure drop limitations Flow Characteristic Approximately linear Disk Rotation Counterclockwise to open when viewed from actuator side of valve body through 90 degrees of disk rotation 1 This material is not listed in EN 125...

Страница 3: ...aterial selection Table 4 Maximum Allowable Inlet Pressure for CW2M and M35 2 Valves TEMPERATURE CW2M 1 M35 2 1 150 2 300 2 PN 10 2 PN 16 2 PN 25 2 PN 40 2 150 2 300 2 PN 10 2 PN 16 2 PN 25 2 PN 40 2 _C Bar Bar 46 to 38 50 100 150 200 232 20 0 19 5 17 7 15 8 13 8 12 7 51 7 51 7 51 5 50 3 48 3 47 0 10 0 9 9 9 4 9 4 9 1 9 1 16 0 15 9 15 1 15 1 14 6 14 6 25 0 24 8 23 6 23 6 22 9 22 9 40 0 39 6 37 8 3...

Страница 4: ...ese materials mate with EN and ASME flanges but are not included in EN or ASME pressure temperature ratings and must not be installed in systems requiring conformance to EN or ASME standards Maximum allowable inlet pressures for 8580 valve bodies made of CW2M or M35 2 construction materials are shown in table 4 1 Install a three valve bypass around the control valve assembly if continuous operatio...

Страница 5: ...6 M20X2 5 100 150 16 M20X2 5 100 16 M20X2 5 100 16 M24X3 110 16 M24X3 110 200 16 M20X2 5 100 24 M20X2 5 100 24 M24X3 120 24 M27X3 130 250 24 M20X2 5 110 24 M24X3 120 24 M27X3 130 24 M30X3 5 140 300 24 M20X2 5 120 24 M24X3 120 24 M27X3 140 24 M30X3 5 150 VALVE SIZE WAFER STYLE SINGLE FLANGE STYLE CL150 CL300 CL150 CL300 NPS No of Stud Bolts Size Dia Thread Inch A Dimen sion Inch No of Stud Bolts Si...

Страница 6: ...body is not necessarily grounded when installed in a pipeline If the valve is used in a flammable or hazardous atmosphere or for oxygen service an explosion could result due to a discharge of static electricity from the valve components To avoid personal injury or property damage always make sure the valve body is grounded to the pipeline before putting the control valve assembly into operation in...

Страница 7: ... equipment D The valve packing box may contain process fluids that are pressurized even when the valve has been removed from the pipeline Process fluids may spray out when removing the packing hardware or packing rings or when loosening the packing box pipe plug D Check with your process or safety engineer for any additional measures that must be taken to protect against process media Packing Main...

Страница 8: ...E V RING GRAPHITE RIBBON THESE TWO SURFACES SHOULD REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS KEY 28 NOTES WITH CONDUCTIVE PACKING THE FEMALE ADAPTOR IN PTFE V RING PACKING IS CARBON FILLED PTFE APPLY LUBRICANT 1 2 3 Figure 4 Packing Arrangement Details GE39901 A GE39986 A GE40113 A GE40118 A ...

Страница 9: ...o allow proper readjustment of the disk position WARNING The edges of a rotating disk have a shearing effect that may result in personal injury To help prevent such injury stay clear of the disk edges when rotating the disk key 3 CAUTION Damage to the disk key 3 may occur if the disk is not closed when the valve is being removed from the pipeline If necessary apply operating pressure to the actuat...

Страница 10: ...he valve body and drain the process media from both sides of the valve If using a power actuator also shutoff all pressure lines to the power actuator release all pressure from the actuator Use lock out procedures to be sure that the above measures stay in effect while you work on the equipment CAUTION When removing the actuator use a wheel puller to separate the actuator parts from the valve shaf...

Страница 11: ...eline 2 Unscrew the flange bolts and remove the valve from the pipeline 3 Unscrew the machine screws key 14 remove the retainer clip key 13 and remove the seal retainer key 2 4 Remove the seal ring assembly key 4 5 The valve must be closed during seal ring installation to permit accurate centering of the seal To install the new seal ring assembly D For a soft seal if the spring key 5 was disassemb...

Страница 12: ...ure lines to the power actuator release all pressure from the actuator Use lock out procedures to be sure that the above measures stay in effect while you work on the equipment CAUTION When removing the actuator in the following step use a wheel puller to separate the actuator parts from the valve shaft Do not drive the actuator parts off the valve shaft because this could damage valve trim compon...

Страница 13: ...ncompatible with the process media Any use of lubricant can lead to the sudden explosion of media due to the oil oxygen mixture causing personal injury or property damage CAUTION To avoid possible product damage ensure the bearing tabs are oriented correctly when installing in the following procedure See figure 5 for proper orientation of the bearings 1 If new bearings key 6 are required install a...

Страница 14: ... ring assembly onto the disk Set the retainer onto the seal D For the flow ring construction place the gasket key 41 onto the valve body Set the retainer onto the gasket 7 Attach the seal retainer key 2 and the retainer clips key 13 to the valve body and secure with the machine screws key 14 8 Insert a packing box ring key 23 into the packing box 9 For standard packing install the packing accordin...

Страница 15: ... body see figure 7 Rotating the disk key 3 past the fully closed position will damage the seal ring key 4 To prevent this damage use the following procedures D For actuators with adjustable travel stops such as a Type 2052 1051 1052 size 33 1066 or 1066SR actuator make certain the actuator travel stop prevents the disk from rotating past the fully closed position D For actuators with an adjustable...

Страница 16: ... THROUGH 12 VALVES CURVED ARROWS IN VALVE CLOSED COLUMN INDICATE ROTATION REQUIRED TO OPEN VALVE COUNTERCLOCKWISE WHEN VIEWED FROM ACTUATOR SIDE OF VALVE ARROWS IN MOUNTING POSITION COLUMNS INDICATE DIRECTION OF ACTUATOR ROD TRAVEL REQUIRED TO OPEN VALVE 6 PDTC PUSH DOWN TO CLOSE PDTO PUSH DOWN TO OPEN RIGHT HAND STYLE A PDTO STYLE B PDTC STYLE C PDTC STYLE D PDTO LEFT HAND FORWARD FLOW 43A5323 B ...

Страница 17: ...RO SEAL packing system into an existing 8580 valve are included in the kits Worn shafts packing box damage or other components that do not meet Emerson Process Management finish specifications dimensional tolerances and design specifications may adversely alter the performance of the retrofit kit ENVIRO SEAL Packing System Retrofit Kits SHAFT DIAMETER SINGLE PTFE PACKING GRAPHITE PACKING mm Inches...

Страница 18: ... 4 GE23792X042 DN 150 NPS 6 GE16687X042 DN 200 and 250 NPS 8 and 10 GE28145X042 DN 300 NPS 12 GE20539X022 Key Description Part Number 7 Expansion Pin continued S20910 DN 50 NPS 2 GE27079X012 DN 80 NPS 3 GE21165X012 DN 100 NPS 4 GE23792X012 DN 150 NPS 6 GE16687X012 DN 200 and 250 NPS 8 and 10 GE28145X012 DN 300 NPS 12 GE20539X012 8 Taper Pin 2 req d S17400 DN 50 NPS 2 16A5511X122 DN 80 NPS 3 GE3045...

Страница 19: ...7414X012 DN 150 NPS 6 12B7438X012 DN 200 and 250 NPS 8 and 10 12B7450X012 DN 300 NPS 12 12B7462X012 Key Description Part Number 24 Packing Set ENVIRO SEAL Graphite DN 50 NPS 2 13B8816X012 DN 80 NPS 3 13B8816X032 DN 100 NPS 4 13B8816X052 DN 150 NPS 6 13B8816X092 DN 200 and 250 NPS 8 and 10 13B8816X112 DN 300 NPS 12 13B8816X142 25 Packing Follower 26 Packing Flange 27 Packing Stud 28 Packing Nut 29 ...

Страница 20: ...es Singapore 128461 Singapore www Fisher com The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which...