background image

www.Fisher.com

Fisher

 8532 High-Performance Butterfly Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Educational Services

2

. . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Valve Orientation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Before Installing the Valve

5

. . . . . . . . . . . . . . . . . . . . .

Adjusting the Actuator Travel Stops or Travel

7

. . . . .

Installing the Valve

7

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Packing Adjustment and Shaft Bonding

9

. . . . . .

Maintenance

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing and Replacing the Actuator

12

. . . . . . . . .

Packing Maintenance

12

. . . . . . . . . . . . . . . . . . . . . . . .

Removing the Valve

13

. . . . . . . . . . . . . . . . . . . . . . . . .

Seal Maintenance

14

. . . . . . . . . . . . . . . . . . . . . . . . . . .

PTFE Seals

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NOVEX, Phoenix III and/or

Phoenix III Fire‐Tested Seals

16

. . . . . . . . . . . .

Anti‐Blowout Design, Packing, Valve Shaft,

Disk, and Bearing Maintenance

17

. . . . . . . . . . . . .

Installing the Two‐Piece Shaft

19

. . . . . . . . . . . . .

Gasket Retainer

21

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts List

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 1. Fisher 8532 Valve with 1061 Actuator and
FIELDVUE™ DVC6200 Digital Valve Controller

W9138-1

Introduction

Scope of Manual

This instruction manual provides installation, maintenance, and parts information for NPS 14 through 24 Fisher 8532
high-performance butterfly valves.

Do not install, operate, or maintain an 8532 valve without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. 

To avoid personal injury or property damage, it is important to

carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings.

 If you

have any questions about these instructions, contact your 

Emerson sales office

 or Local Business Partner  before

proceeding.

Description

The valve is available in either a wafer (flangeless), lugged (single‐flange), or double flange body design, with a variety
of seals and internal components. The pressure‐assisted seal provides tight shutoff. The spline or keyed drive shaft
combines with a variety of actuators. Maximum inlet pressure/temperature ratings are consistent with CL150 and
CL300.

Instruction Manual

D101550X012

8532 Valve

June 2017

Содержание Fisher 8532

Страница 1: ...truction manual provides installation maintenance and parts information for NPS 14 through 24 Fisher 8532 high performance butterfly valves Do not install operate or maintain an 8532 valve without being fully trained and qualified in valve actuator and accessory installation operation and maintenance To avoid personal injury or property damage it is important to carefully read understand and follo...

Страница 2: ...tio 2 100 to 1 Noise Levels See Fisher Catalog 12 for sound pressure level prediction Valve Body Classification Wafer and Lugged face to face dimensions are in compliance with MSS SP68 and API 609 standards Double Flange valve bodies comply with API 609 short face to face dimensions Valve bodies are designed for installation between ASME B16 5 CL150 and CL300 raised face flanges Disk Rotation Cloc...

Страница 3: ... Backup O Ring PTFE Backup O Ring 29 to 93 43 to 149 54 to 182 29 to 204 73 to 204 20 to 200 45 to 300 65 to 360 20 to 400 100 to 400 UHMWPE 5 Seal Ring CL150 Only EPR Backup O Ring Fluorocarbon Backup O Ring 54 to 93 29 to 93 65 to 200 20 to 200 Phoenix III and or Fire Tested Construction S31600 and PTFE Seal Ring with Nitrile Backup O Ring Chloroprene Backup O Ring EPR Backup O Ring Fluorocarbon...

Страница 4: ...N When ordered the valve configuration and construction materials were selected to meet particular pressure temperature pressure drop and controlled fluid conditions Responsibility for the safety of process media and compatibility of valve materials with process media rests solely with the purchaser and end user Since some body trim material combinations are limited in their pressure drop and temp...

Страница 5: ...ply pressure to the pneumatic actuator or other steps as necessary Table 3 Valve Body Data CL150 VALVE SIZE NPS SHAFT DIA AT YOKE BEARING FACE TO FACE DIMENSION 1 MINIMUM I D 2 APPROXIMATE WEIGHT KILOGRAMS Wafer and Lugged Double Flange mm Wafer Lugged Double Flange 14 30 2 92 1 191 331 2 71 7 94 8 152 16 31 75 101 6 216 375 2 93 9 137 9 201 18 38 1 114 3 222 418 8 139 3 178 3 243 20 44 45 127 0 2...

Страница 6: ...pecifications 2 Minimum I D is the minimum pipe or flange I D required for disk swing clearance Applies to wafer and lugged valve bodies only CAUTION When using an actuator the actuator travel stop or actuator travel for actuators without adjustable stops must be adjusted so the disk stop in the valve does not absorb the output of the actuator Failure to limit the actuator travel as described in t...

Страница 7: ... adjustment is necessary to be certain that the actuator output torque is fully absorbed by the actuator travel stop or by the actuator The internal travel stop in the valve body should not absorb any of the actuator torque 2 Before installing the valve actuator assembly in the process line cycle the valve several times to be sure the valve disk returns to the proper position Installing the Valve ...

Страница 8: ...1 8 UNC 0 24 70 2 75 300 0 40 1 1 8 8 UNC 0 40 89 3 50 16 150 0 32 1 8 UNC 0 32 76 3 00 300 0 40 1 1 4 8 UNC 0 40 95 3 75 18 150 0 32 1 1 8 8 UNC 0 32 82 3 25 300 0 48 1 1 4 8 UNC 0 48 101 4 00 20 150 0 40 1 1 8 8 UNC 0 40 89 3 50 300 0 48 1 1 4 8 UNC 0 48 101 4 00 24 150 0 40 1 1 4 8 UNC 0 40 95 3 75 300 0 48 1 1 2 8 UNC 0 48 114 4 50 Double Flange Bodies Valve Size NPS Valve Rating Number of Thr...

Страница 9: ...he flow properly enters the valve as indicated by the flow tag Then install the valve and the gaskets between the flanges into the cradle formed by the flange bolts 4 Install the remaining flange bolts D For Wafer Style Valves Make sure the gaskets are centered on the gasket sealing surfaces of the flange and body 5 For all Valves Tighten the flange bolts in an alternating criss cross fashion to a...

Страница 10: ... leakage Excessive tightening of packing will accelerate wear and could produce higher rotating friction loads on the valve stem If necessary refer to the Packing Maintenance section 2 The ENVIRO SEAL Packing Systems will not require this initial re adjustment Refer to the separate instruction manual Fisher ENVIRO SEAL Packing System for Rotary Valves D101643X012 for repair and adjustment procedur...

Страница 11: ...ews 6 For more information refer to the Packing Maintenance section below Maintenance Valve parts are subject to normal wear and must be inspected and replaced as necessary The frequency of inspection and replacement depends upon the severity of service conditions Key numbers in this procedure are shown in figures 9 and 10 unless otherwise indicated WARNING Avoid personal injury from sudden releas...

Страница 12: ...tor travel can result in damage to the valve shaft s or other valve components Packing Maintenance The 8532 control valve is designed so the packing can be replaced without removing the valve from the process pipeline CAUTION For non ENVIRO SEAL packing Tighten the packing follower nuts only enough to prevent shaft leakage Excessive tightening will accelerate wear of the packing and could produce ...

Страница 13: ...g bore might cause leakage 4 Before installing new packing clean the packing box 5 Install new packing one ring at a time using the packing follower as a driver If using split ring packing stagger the splits in the rings to avoid creating a leak path 6 Reinstall packing parts Refer to figures 9 and 10 for sequence of packing parts Removing the Valve 1 Disconnect any operating lines providing air p...

Страница 14: ...sed by the impact of a falling or tipping of a large valve Support large valves during maintenance 2 Lay the valve flat on a work bench in a secure position with the retaining ring key 18 and retaining ring screws key 19 facing up Properly secure the valve on a suitable worktable so it cannot slip twist or fall during maintenance Remove all retaining ring screws 3 Remove the retaining ring by plac...

Страница 15: ...astener materials please contact your Emerson sales office Local Business Partner PTFE Seals 1 Locate the replacement seal ring key 5 and note the shape of the ring The ring is wider across one edge diameter and narrower across the other edge diameter Around the outside circumference is one wide groove Before installing the seal ring into the valve body place the O ring key 6 into the wide outer g...

Страница 16: ...after placement of the seal ring in the valve body using a blunt end screwdriver or the seal installation tool in the maintenance kit Do not use the screwdriver or seal tool directly on the metal seat Use tools on the O ring only 2 With the seal ring inserted all the way around the body T slot now lay the O ring into the opening between the valve body and the seal ring Use the seal tool to apply p...

Страница 17: ...ow be done For the screw torque values refer to table 6 Anti Blowout Design Packing Valve Shaft Disk and Bearing Maintenance Note The 8532 valve has a two piece shaft In these procedures the shaft with the splined end is called the upper shaft key 3 The shaft opposite the upper shaft is called the lower follower shaft key 4 CAUTION When using an actuator the actuator travel stop or actuator travel...

Страница 18: ...ance kit is available use the pin extractor to remove the disk pins Select the correct size pin extractor tip with screws of proper thread size to match the thread size in the disk pins If you do not have a kit see steps c and d below b Screw the pin extractor tip into the pin as far as possible With an upward straight sliding motion pull out the pin Repeat the same procedure for the other pins c ...

Страница 19: ...a Collect the thrust bearings 10 Remove the bearings key 7 Using a suitable punch or puller drive or pull the bearings into the valve body bore from the upper shaft bearing bore Remove the bearing from the lower shaft bearing bore 11 Inspect the valve body bore bearings bearing bores and packing box for damage Note In these instructions the drive shaft with splined end is called the upper shaft ke...

Страница 20: ...e upper shaft thrust bearing key 24 in the valve body bore against the counterbore of the upper shaft bearing bore Push the upper shaft through the packing box side into the bearing bore just enough to hold the thrust bearing 7 When installing the lower bearing key 4 insert one or more bearings into the lower shaft bearing bore so it is flush with the body bore 8 Insert the lower shaft through the...

Страница 21: ...h the lower shaft 13 Refer to the Anti Blowout Design Packing Valve Shaft Disk and Bearing Maintenance procedures in this manual to re install the packing and anti blowout design Gasket Retainer Valves with a two piece shaft use a gasket retainer and gasket keys 20 and 21 to cover the lower shaft opening in the valve body The gasket is held in place by the gasket retainer and four hex head bolts a...

Страница 22: ...ersely affect the performance of the valve and could cause personal injury and property damage Retrofit Kits Retrofit kits include all parts required for installation of the ENVIRO SEAL packing system into existing high performance butterfly valves Retrofit kits are available for single PTFE packing See table 7 for retrofit kit part numbers Retrofit Kit Included Parts Key Description Quantity 10 1...

Страница 23: ...RE RATING SHAFT DIAMETER 1 2 mm Inch RETROFIT KITS REPAIR KITS PTFE PTFE 14 CL150 34 9 1 3 8 RRTYXRT0592 RRTYX000172 CL300 50 8 2 RRTYXRT0602 RRTYX000182 16 CL150 38 1 1 1 2 RRTYXRT0612 RRTYX000192 CL300 57 2 2 1 4 RRTYXRT0622 RRTYX000202 18 CL150 44 5 1 3 4 RRTYXRT0632 RRTYX000212 CL300 63 5 2 1 2 RRTYXRT0642 RRTYX000222 20 CL150 50 8 2 RRTYXRT0652 RRTYX000182 24 CL150 63 5 2 1 2 RRTYXRT0662 RRTY...

Страница 24: ...ion 21 Gasket 22 Lockwasher 4 req d 23 Cap Screw 4 req d 24 Thrust Bearing 26 Retaining Ring Gasket 27 Cap Screw Actuator 4 req d not shown 28 Hex Nut Actuator 4 req d not shown 29 Nameplate not shown 32 Drive Screw 2 req d 33 Flow Direction Arrow not shown 34 Packing Box Ring 35 Disk Shaft Pin Assembly not shown ENVIRO SEAL Packing System See figure 11 10 Anti Blow Flange 17 Hex Jam Nut 4 req d 1...

Страница 25: ...Instruction Manual D101550X012 8532 Valve June 2017 25 Figure 9 Fisher 8532 NPS 14 24 CL150 300 GE58725 A PARTS NOT SHOWN KEY 26 29 32 33 38 111 112 113 USE ONLY WITH SOFT SEAL AND PHOENIX III SEAL 1 1 ...

Страница 26: ...anual D101550X012 8532 Valve June 2017 26 Figure 10 Fisher 8532 NPS 14 24 CL150 300 Double Flange Valve Body GE58760 A PARTS NOT SHOWN KEY 26 29 32 33 38 111 112 113 USE ONLY WITH SOFT SEAL AND PHOENIX III SEAL 1 1 ...

Страница 27: ...ENVIRO SEAL Packing Systems PTFE PACKING SYSTEM 34B7524 B STACKING ORDER OF PTFE PACKING RINGS 14B0095 A 1 14B0086 A 34B7524 B GRAPHITE PACKING SYSTEM STACKING ORDER OF GRAPHITE PACKING RINGS NOTES VALVES WITH SHAFTS LARGER THAN 38 1 mm 1 1 2 INCH USE GRAPHITE RINGS ...

Страница 28: ...ailable upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice E 1990 2017 Fisher Controls International LLC All rights reserved Fisher and ENVIRO SEAL are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co Emerson Automation Solutions Emerson and the Emerson logo are...