Design 3024S Actuator
Instruction Manual
Form 5421
June 1999
3
Table 2a.
Additional Specifications, Action - Air to Close (ATC)
Type
Spring Set
No. / Qty/
Color
Travel
Maximum Operating
Pressure to Diaphragm
Range
Maximum Output Thrust
(Maximum Actuator Stem
Force)
(1)
Inch
mm
Psig
Bar
Psig
Bar
Lb
N
GA 1.21
218 / 5 / R
218 / 7 / G
0.63
0.63
16
16
19
−
33
23
−
44
1.3
−
2.3
1.6
−
3.0
87
87
6
6
461
568
2054
2528
GA 1.31
219 / 3 / B
211 / 6 / R
212 / 5 / G
212 / 7 / G
0.63
0.63
0.63
0.63
16
16
16
16
3
−
15
6
−
15
22
−
35
29
−
46
0.2
−
1.0
0.4
−
1.0
1.5
−
2.4
2.0
−
3.2
87
87
87
87
6
6
6
6
214
429
1608
2144
954
1908
7155
9540
211 / 3 / R
212 / 5 / G
212 / 7 / G
1.26
1.26
1.26
32
32
32
- - -
10
−
33
13
−
46
0.2
−
1.0
0.7
−
2.3
0.9
−
3.2
87
87
87
6
6
6
220
769
989
978
3423
4401
GA 1.41
220 / 4 / R
221 / 8 / G
221 / 10 G
221 / 12 / G
221 / 14 / G
1.26
1.26
1.26
1.26
1.26
32
32
32
32
32
- - -
10
−
26
15
−
35
18
−
41
21
−
46
0.2
−
1.0
0.7
−
2.3
1.0
−
2.4
1.2
−
2.8
1.4
−
3.2
87
87
87
87
87
6
6
6
6
6
391
1370
1958
2349
2741
1742
6097
8710
10452
12194
1. Based on zero operating pressure to diaphragm for Type 3024S actuator and valve travel 0%. This does not consider limitations to valve, such as stem buckling loads.
Table 2b.
Additional Specifications, Action - Air to Open (ATO)
Type
Spring Set
No. / Qty/
Color
Travel
Maximum Operating
Pressure to Diaphragm
Range
Maximum Output Thrust
(Maximum Actuator Stem
Force)
(1)
Inch
mm
Psig
Bar
Psig
Bar
Lb
N
GA 1.21
217 / 3 / R
218 / 5 / G
218 / 7 / G
0.63
0.63
0.63
16
16
16
3
−
15
19
−
34
23
−
44
0.2
−
1.0
1.3
−
2.3
1.6
−
3.0
87
87
87
6
6
6
1528
1131
917
6800
5032
4080
GA 1.31
219 / 3 / B
211 / 6 / R
212 / 5 / G
212 / 7 / G
0.63
0.63
0.63
0.63
16
16
16
16
3
−
15
6
−
15
22
−
35
29
−
46
3
−
15
6
−
15
22
−
35
29
−
46
87
87
87
87
6
6
6
6
4395
4395
3164
2461
19550
19550
14076
10948
211 / 3 / R
212 / 5 / G
212 / 7 / G
1.26
1.26
1.26
32
32
32
3
−
15
10
−
33
13
−
46
0.2
−
1.0
0.7
−
2.3
0.9
−
3.2
87
87
87
6
6
6
4519
3344
2531
20100
14874
11256
GA 1.41
220 / 4 / R
221 / 8 / G
221 / 10 G
221 / 12 / G
221 / 14 / G
1.26
1.26
1.26
1.26
1.26
32
32
32
32
32
3
−
15
10
−
26
15
−
35
18
−
41
21
−
46
0.2
−
1.0
0.7
−
2.3
1.0
−
2.4
1.2
−
2.8
1.4
−
3.2
87
87
87
87
87
6
6
6
6
6
8161
6855
5876
5223
4570
36300
30492
26136
23232
20338
1. Based on zero operating pressure to diaphragm for Type 3024S actuator and valve travel 0%. This does not consider limitations to valve, such as stem buckling loads.
Installation
WARNING
Personal injury or equipment damage
caused by sudden release of pressure
may result if the valve assembly is
installed where service conditions
could exceed the limits given in table 1
and 2 or the appropriate nameplates.
To avoid such injury or damage,
provide a relief valve for overpressure
protection as required by accepted
industry or local, state and federal
codes and good engineering practices.
A Type 3024S diaphragm actuator is normally
shipped mounted on a valve. Refer to the
appropriate valve instruction manual when installing
the valve in the pipeline. If the actuator is shipped
separately or if it is necessary to mount the actuator
on the valve, perform the Actuator Mounting
procedure given below. For information on mounting
the positioner, refer to the positioner instruction