Instruction Manual
D100348X012
2625 and 2625NS Volume Booster
January 2015
5
The booster may also be directly mounted to the actuator by using an actuator yoke mounting bracket (see figure 5)
or casing mounting bracket.
Pressure Connections
The input signal connection is 1/4 NPT. The supply and output connections are 3/4 NPT (minimum pipe size
recommended for nipple mounting is 1/2 NPT). Connections to the volume booster should be made as indicated in
figure 3. Connections for two typical applications are shown in figure 2. Ensure that the piping is of proper size to meet
the capacity demands of the booster and that you equip the actuator with properly sized input connections.
Figure 2. Typical Installations
2625 OR 2625NS
VOLUME BOOSTER
B2372‐1
2625 OR 2625NS
VOLUME BOOSTER
2625 OR 2625NS
VOLUME BOOSTER
POSITIONER OUTPUT
POSITIONER
POSITIONER OUTPUT
(TOP CYL)
SIGNAL
SUPPLY
POSITIONER
POSITIONER OUTPUT
(BOTTOM CYL)
PIPE TEE
PIPE BUSHING
BODY
BODY PROTECTOR
INPUT SIGNAL
PIPE TEE
PIPE BUSHING
BODY
BODY PROTECTOR
ACTUATOR
ACTUATOR
OPTIONAL
DIAGNOSTIC
CONNECTION
OPTIONAL
DIAGNOSTIC
CONNECTION
SUPPLY
67D, 67DR,
OR 95H
PIPE NIPPLE
PIPE NIPPLE
WITH A PISTON ACTUATOR
WITH A DIAPHRAGM ACTUATOR
67D, 67DR, OR 95H