224
EZMotion User/Programming Guide
www.controltechniques.com
Revision: A8
instruction, MM represents the desired menu, and PP represents the desired parameter number.
SP Menu Drive Decimal
SPMenu.DriveDecimal
This parameter is used behind the scenes in PowerTools Pro when reading or writing to a SP menu parameter using the Drive Watch
Window. These are not to be used inside a user program.
If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction,
MM represents the desired menu, and PP represents the desired parameter number.
SP Menu Error Status
SPMenu.ErrorStatus
This parameter is used behind the scenes in PowerTools Pro when reading or writing to a SP menu parameter using the Drive Watch
Window button. These are not to be used inside a user program.
If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction,
MM represents the desired menu, and PP represents the desired parameter number.
SP Menu ID
SPMenu.MenuID
This parameter is used behind the scenes in PowerTools Pro when reading or writing to a SP menu parameter using the Drive Watch
Window button. These are not to be used inside a user program.
If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction,
MM represents the desired menu, and PP represents the desired parameter number.
SP Menu Parameter ID
SPMenu.ParamID
This parameter is used behind the scenes in PowerTools Pro when reading or writing to a SP menu parameter using the Drive Watch
Window button. These are not to be used inside a user program.
If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction,
MM represents the desired menu, and PP represents the desired parameter number.
SP Menu Value
SPMenu.Value
This parameter is used behind the scenes in PowerTools Pro when reading or writing to a SP menu parameter using the Drive Watch
Window button. These are not to be used inside a user program.
If writing to or reading from a Unidrive SP menu parameter in a program, use the Menu.MM.PP instruction instead. In this instruction,
MM represents the desired menu, and PP represents the desired parameter number.
Drive Power Up Time – Hrs.Min
SPPowerUpTimeHoursMinutes
The Drive Power Up Time is the time elapsed since power has been cycled to the drive. The format for this parameter is Years.Days
and Hours.Minutes. These values must be used in combination to find the actual time. This parameter can be found on the Errors
view while Online with PowerTools Pro.
Total Power Up Time = SPPowerUpTimeYea SPPowerUpTimeHoursMinutes
Drive Power Up Time – Yrs.Days
SPPowerUpTimeYearsDays
The Drive Power Up Time is the time elapsed since power has been cycled to the drive. The format for this parameter is Years.Days
and Hours.Minutes. These values must be used in combination to find the actual time. This parameter can be found on the Errors
view while Online with PowerTools Pro.
Total Power Up Time = SPPowerUpTimeYea SPPowerUpTimeHoursMinutes
SPRelay Name
SPRelay.#.Name
The relay output on the drive can be given a name. The name can be used in a user program to reference a specific output if
desired. The name can be up to 12 alphanumeric characters, but must begin with a non-numeric character.
SPRelay State
SPRelay.#.Out
The Unidrive SP has relay output that can be used to control devices that require more current than a digital output. The “.Out” at the
Содержание EZMotion
Страница 2: ......
Страница 12: ...x EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 18: ...6 EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 36: ...24 EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 158: ...146 EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 186: ...174 EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 266: ...256 EZMotion User Programming Guide www controltechniques com Revision A8 ...
Страница 267: ......