background image

Figure 1.

 Model ES-665-HF Spring-loaded Hatch

Model ES-665-HF High Flow  

Spring-Loaded Hatch

WARNING

!

Failure to follow these instructions or to 

properly install and maintain this equipment 

could result in an explosion, fire and/or 

chemical contamination causing property 

damage and personal injury or death.
Enardo™ spring-loaded hatch 

must be installed, operated and 

maintained in accordance with federal, 

state and local codes, rules and 

regulations and Emerson Process 

Management Regulator Technologies 

Tulsa, LLC instructions. 
Failure to correct trouble could result in a 

hazardous condition. Call a qualified service 

person to service the unit. Installation, 

operation and maintenance procedures 

performed by unqualified person may 

result in improper adjustment and unsafe 

operation. Either condition may result in 

equipment damage or personal injury. Only 

a qualified person shall install or service the 

spring-loaded hatch.

Introduction

Scope of the Manual

This Instruction Manual provides instructions for installation, 

startup, maintenance and parts ordering information for the 

Model ES-665-HF spring-loaded hatch.

Table of Contents

Introduction ............................................................................1
Specifications ........................................................................2
Principle of Operation ............................................................2
Tagging Information ...............................................................2
Installation and Disassembly .................................................2
Maintenance ..........................................................................5
Parts Ordering .......................................................................7
Parts List................................................................................7

MODEL ES-665-HF WITH CLOSED HATCH

MODEL ES-665-HF WITH OPEN HATCH

P1806

P1807

Product Description

The Model ES-665-HF high flow gauge hatch is designed 

to provide much higher flow rates than standard gauge 

hatches, while maintaining the industry leading, tight sealing 

performance of the ES-665 Series. It also provides trouble 

free operation with maintenance. The primary function of the 

Model ES-665-HF high flow hatch is to prevent the loss of 

vapors in a closed storage system and provide pressure and 

vacuum relief.

Instruction Manual

D104266X012
March 2019

Model ES-665-HF

North America 

Only

Содержание Enardo ES-665-HF

Страница 1: ... injury Only a qualified person shall install or service the spring loaded hatch Introduction Scope of the Manual This Instruction Manual provides instructions for installation startup maintenance and parts ordering information for the Model ES 665 HF spring loaded hatch Table of Contents Introduction 1 Specifications 2 Principle of Operation 2 Tagging Information 2 Installation and Disassembly 2 ...

Страница 2: ...ds are enforced Principle of Operation Enardo gauge hatches are designed to control evaporation losses and protect tanks against excessive pressure or vacuum When the tank pressure is above the setpoint of the hatch the cover opens to relieve excess pressure When the overpressure has dissipated the cover reseats onto the base to provide tight seal Tagging Information The Model ES 665 HF high flow ...

Страница 3: ...PI 20 0 63 16 00 75 101 7 Assumptions Use of SAE grade 5 bolts or studs or stronger No lubricant Elastomer 70 Durometer Shore A Notes Flat faced flanges should never be mated to a raised face flange for installation If lubricant is used on bolts apply torque reduction factor listed in Lubricant Table For best results hardened steel washers should be used on all cast flange bolted connections Figur...

Страница 4: ...great enough to cause the spring capsule assembly to have a safety risk Accessing Spring Capsule Assembly or Center Assembly Note The Spring Capsule Assembly must be removed before removing the Center Assembly The Model ES 665 HF Series Center Assembly can also be installed as a retrofit into an existing Model ES 660 HF by following the steps outlined in this section WARNING Springs are energy sto...

Страница 5: ...m Maintenance Perform a scheduled maintenance every three 3 months and more frequently in corrosive or dusty atmospheres Inspect the pressure gaskets and vacuum gaskets for normal maintenance To ensure efficient operation of all hatches carefully wipe off the pressure and vacuum seats and gaskets with a clean non abrasive lint free cloth or paper towel every time the hatch is opened This prevents ...

Страница 6: ...ow steps 1 through 4 in reverse order Ensure the pivot pad is installed flat on top of the center assembly before the spring capsule assembly is attached See Figure 15 for detailed view of the vacuum assembly High Flow Model ES 665 HF Hatch Replacement Parts Spring Capsule Assembly WARNING Under no circumstances should the user attempt to disassemble the spring capsule assembly The spring capsule ...

Страница 7: ...2 Center Aluminum 4556002 13 Flat Washer 3 8 in 316 Stainless steel 2012504 14 010 O ring Viton 2012710 15 Seal Support Aluminum 8554636 16 Vacuum Gasket Per order 17 Vacuum Pallet Disk Aluminum 8559029 18 Hinge Spring 302 Stainless steel 4504005 19 Clevis Pin 5 6 x 2 1 2 in Zinc plated Carbon steel 4505110 20 Hex Nylock Nut 3 8 in 16 316 Stainless steel 2059201 21 Base Aluminum 4507303 22 Cotter ...

Страница 8: ...as been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management Regulator Technologies Tulsa LLC does not assume responsibili...

Отзывы: