10
E300 Installation and Commissioning Guide
Issue Number: 1
2.4 Ratings
The
E300 Standard Elevator
drive is configured for Heavy Duty operation, For constant torque applications or applications which require a high
overload capability, or full torque is required at low speeds (e.g. elevators, hoists). The thermal protection is set to protect force ventilated induction
motors and permanent magnet servo motors by default.
Motor I
2
t protection defaults to be compatible with:
N
If the application uses a self ventilated (TENV/TEFC) induction motor and increased thermal protection is required for speeds below 50 % base
speed, then this can be enabled by setting
Low Speed Thermal Protection Mode
(
B44
) = On (1).
The rating label details the available output current, under the following conditions:
•
40
°
C (104
°
F) maximum abient
•
1000 m altitude
•
8 kHz switching frequency
•
Typical elevator profile (50% ED)
•
IGBT lifetime optimization enabled (reduction of switching frequency based on the drive inverter temperature.
The input current is affected by the supply voltage and impedance. The input current given on the rating label is the typical input current and is stated
for a balanced supply.
Table 2-1 200 V drive and AC fuse ratings
Table 2-2 400 V drive and AC fuse ratings
NOTE
Fuses
The AC supply to the drive must be installed with suitable protection against overload and short-circuits. The following section shows
recommended fuse ratings. Failure to observe this requirement will cause risk of fire.
Model
Max. cont.
input current
Heavy Duty
Fuse
Max. cont.
output current
Nom power
@
230 V
Motor power
@
230 V
IEC
UL
3 ph
Nom
Class
Nom
Class
A
A
kW
hp
A
A
03200106
20
10.6
2.2
3
25
gG
25
CC, J or T*
04200137
20
13.7
3
3
25
gG
25
CC, J or T*
04200185
28
18.5
4
5
32
30
05200250
31
25
5.5
7.5
40
gG
40
CC, J or T*
06200330
48
33
7.5
10
63
gG
60
CC, J or T*
06200440
56
44
11
15
63
70
07200610
67
61
15
20
80
gG
80
CC, J or T*
07200750
84
75
18.5
25
100
100
07200830
105
83
22
30
125
125
Model
Max. cont.
input current
Heavy Duty
Fuse
Max. cont.
output current
Nom power
@
400 V
Motor power
@
460 V
IEC
UL
3ph
Nom
Class
Nom
Class
A
A
kW
hp
A
A
03400062
13
6.2
2.2
3.0
20
gG
20
CC, J or T*
03400078
13
7.8
3
5.0
20
20
03400100
16
10
4
5.0
20
20
04400150
19
15
5.5
10.0
25
gG
25
CC, J or T*
04400172
24
17.2
7.5
10.0
32
30
05400270
29
27
11
20
40
gG
35
CC, J or T*
05400300
30
30
15
40
35
06400350
36
35
15
25
63
gR
40
HSJ or DFJ
06400420
46
42
18.5
30
63
50
06400470
60
47
22
30
63
70
07400660
74
66
30
50
100
gG
80
CC, J or T*
07400770
88
77
37
60
100
100
07401000
105
100
45
75
125
125