background image

 

DVS205 

 April 

2011 

Technical Specifications

DVS205 Dual-Variable Sensor 

The DVS205 Dual-Variable Sensor (DVS205) 
provides static pressure and differential pressure 
inputs to a FloBoss™ 103, FloBoss 107E, or FloBoss 
500-Series Flow Manager. The DVS205 
communicates via a serial format with the FloBoss. 

 

Remote Automation Solutions 

Website: www.EmersonProcess.com/Remote 

D301569

X012 

Variables 

Functionally, the DVS205 is a digital transmitter that 
measures two flow-related variables simultaneously: 
differential pressure and static pressure. These 
variables are continuously available to the FloBoss 
unit that polls the DVS205.  

Transducer and Electronics 

The DVS205 contains a transducer and an 
electronics circuit. The transducer uses capacitance-
cell technology to sense differential pressure and 
piezoresistive technology to sense the static 
(absolute or gauge) pressure. 

The transducer electronics convert the pressure 
variables directly into a digital format, allowing

accurate correction and compensation. A 
microprocessor linearizes and corrects the raw 
pressure signals (from the sensor) using 
characterization data stored in non-volatile memory. 

The electronics also allow the DVS205 to 
communicate with a FloBoss using a Serial 
Peripheral Interface (SPI).  

Accuracy 

Two versions of the DVS205 are available: 

ƒ

 

205P with reference accuracy of 0.075% of the 
full span.  

ƒ

 

205E with reference accuracy of 0.10% of the 
full span.  

Mounting  

The DVS205 is factory installed on a FloBoss™ 103, 
FloBoss 107E, or FloBoss 500-Series Flow Manager 
to comply with agency requirements. Attached to the 
bottom of the sensor body is a Coplanar™ flange. 
This flange allows the DVS205 to mount on an 
integral orifice assembly or manifold valve.  

 
 
 

Coupling 

Sensor Body 

Coplanar

 

Flange 

W8826-A 

 

DVS205 Dual-Variable Sensor

 

Содержание DVS205

Страница 1: ...nd piezoresistive technology to sense the static absolute or gauge pressure The transducer electronics convert the pressure variables directly into a digital format allowing accurate correction and compensation A microprocessor linearizes and corrects the raw pressure signals from the sensor using characterization data stored in non volatile memory The electronics also allow the DVS205 to communic...

Страница 2: ... error 0 20 of DP Reading per 1000 psi 68 9 bar Over Pressure Limit 3 626 psi 250 bar applied on either or both sides without damage to the sensor Burst Pressure Limit 10 065 psi 694 bar Static Pressure Input Range Either Absolute or Gauge 0 to 5516 kPa 0 to 800 psia psig 0 to 25 000 kPa 0 to 3626 psia psig Turndowns from 1 1 to 10 1 of URL 0 10 of span Reference Accuracy 205E Turndowns from 10 1 ...

Страница 3: ...unting Factory installed on enclosure of FB103 FB107E and FB503 units See respective technical specifications for unit mounting options Connections Process 1 4 18 NPT on 2 1 8 inch centers on coplanar flange Environmental Same as the FloBoss unit in which it is installed Process Seals per ANSI ISA 12 27 01 Meets requirements for a Single Seal device as defined by ANSI ISA 12 27 01 Installation mus...

Страница 4: ...While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which a...

Отзывы: